{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T02:40:57Z","timestamp":1794278457745,"version":"4.9.0"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T00:00:00Z","timestamp":1786406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Oral Health"],"abstract":"<jats:p>\n                    Dental unit waterlines (DUWLs) are highly susceptible to biofilm formation and serve as reservoirs for opportunistic waterborne pathogens, particularly\n                    <jats:italic>Legionella pneumophila<\/jats:italic>\n                    and\n                    <jats:italic>Pseudomonas aeruginosa<\/jats:italic>\n                    . Effective long-term control of microbial contamination remains challenging due to the complex architecture of DUWLs, intermittent water flow, and the limited applicability of thermal disinfection. Routine microbiological surveillance at the University Dental Clinic Vienna identified recurrent contamination of multiple dental units with\n                    <jats:italic>L. pneumophila<\/jats:italic>\n                    and\n                    <jats:italic>P. aeruginosa<\/jats:italic>\n                    . To establish an effective and sustainable water management strategy, three disinfection protocols were evaluated under routine clinical conditions: (A) continuous application of electrolytically generated hypochlorous acid (HOCl), maintaining a free chlorine concentration of 0.3\u20130.6\u2005mg\/L, (B) increased HOCl concentration, and (C) HOCl combined with hydrogen peroxide (H\n                    <jats:sub>2<\/jats:sub>\n                    O\n                    <jats:sub>2<\/jats:sub>\n                    ). Water samples were analyzed according to standardized ISO methods for detection of\n                    <jats:italic>L. pneumophila<\/jats:italic>\n                    ,\n                    <jats:italic>P. aeruginosa<\/jats:italic>\n                    , and heterotrophic plate counts (HPC). Protocol A demonstrated reliable balance between microbiological efficacy, technical compatibility, and operational feasibility. Increased HOCl concentrations provided no relevant additional microbiological benefit and were associated with technical impairments, whereas the combined HOCl\/H\n                    <jats:sub>2<\/jats:sub>\n                    O\n                    <jats:sub>2<\/jats:sub>\n                    protocol showed less microbiological performance. Following standardization to Protocol A, all evaluated units were incorporated into a comprehensive water safety program consisting of continuous disinfection, automated flushing procedures, daily free-chlorine monitoring, and routine microbiological surveillance. During the 3-year follow-up period (2023\u20132025), sustained suppression of\n                    <jats:italic>L. pneumophila<\/jats:italic>\n                    was achieved across the dental unit network, with only isolated residual findings in a single unit. Monitoring further demonstrated that low heterotrophic plate counts did not consistently exclude the presence of opportunistic pathogens, supporting the need for targeted pathogen surveillance in addition to routine HPC monitoring. These findings demonstrate that a standardized HOCl-based water safety program in combination with automated flushing protocols can provide sustainable long-term control of microbial contamination in DUWLs and underscore the importance of pathogen-specific monitoring for a comprehensive microbiological risk assessment.\n                  <\/jats:p>","DOI":"10.3389\/froh.2026.1903381","type":"journal-article","created":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T04:21:15Z","timestamp":1786422075000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Long-term control of Legionella pneumophila and Pseudomonas aeruginosa in dental unit waterlines following optimization of a hypochlorous acid-based water safety program"],"prefix":"10.3389","volume":"7","author":[{"given":"Alexandra","family":"Wolf","sequence":"first","affiliation":[{"name":"Core Facility for Microbiology and Hygiene, University Dental Clinic","place":["Vienna, Austria"]},{"name":"Medical University of Vienna","place":["Vienna, Austria"]},{"name":"The ESCMID Study Group for Legionella Infections (ESGLI)","place":["Basel, Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanya Ezat Abdullah","family":"Abdullah","sequence":"additional","affiliation":[{"name":"Core Facility for Microbiology and Hygiene, University Dental Clinic","place":["Vienna, Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Moritz","sequence":"additional","affiliation":[{"name":"Core Facility for Microbiology and Hygiene, University Dental Clinic","place":["Vienna, Austria"]},{"name":"Medical University of Vienna","place":["Vienna, Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Apostolos","family":"Georgopoulos","sequence":"additional","affiliation":[{"name":"Core Facility for Microbiology and Hygiene, University Dental Clinic","place":["Vienna, Austria"]},{"name":"Medical University of Vienna","place":["Vienna, Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,11]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/438517","article-title":"Pseudomonas aeruginosa acquisition in cystic fibrosis patients in context of otorhinolaryngological surgery or dentist attendance: case series and discussion of preventive concepts","volume":"2015","author":"Mainz","year":"2015","journal-title":"Case Rep Infect Dis"},{"key":"B2","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.jhin.2017.01.009","article-title":"Legionellosis acquired through a dental unit: a case study","volume":"96","author":"Sch\u00f6nning","year":"2017","journal-title":"J Hosp Infect"},{"key":"B3","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1016\/S0140-6736(12)60074-9","article-title":"Pneumonia associated with a dental unit waterline","volume":"379","author":"Ricci","year":"2012","journal-title":"Lancet"},{"key":"B4","author":"Heger","year":""},{"key":"B5","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/MD.0b013e31827f6104","article-title":"Community-acquired Legionella pneumophila pneumonia: a single-center experience with 214 hospitalized sporadic cases over 15 years","volume":"92","author":"Viasus","year":"2013","journal-title":"Medicine"},{"key":"B6","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1128\/CMR.00040-09","article-title":"Antibacterial-Resistant Pseudomonas aeruginosa: clinical impact and complex regulation of chromosomally encoded resistance mechanisms","volume":"22","author":"Lister","year":"2009","journal-title":"Clin Microbiol Rev"},{"key":"B7","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/S1473-3099(17)30753-3","article-title":"Discovery, research, and development of new antibiotics: the WHO priority list of antibiotic-resistant bacteria and Tuberculosis","volume":"18","author":"Tacconelli","year":"2018","journal-title":"Lancet Infect Dis"},{"key":"B8","doi-asserted-by":"publisher","first-page":"2026","DOI":"10.3390\/microorganisms8122026","article-title":"Living with Legionella and other waterborne pathogens","volume":"8","author":"Falkinham","year":"2020","journal-title":"Microorganisms"},{"key":"B9","doi-asserted-by":"publisher","first-page":"475","DOI":"10.3390\/w17040475","article-title":"The case for monitoring for Legionella pneumophila in drinking water distribution systems","volume":"17","author":"LeChevallier","year":"2025","journal-title":"Water"},{"key":"B10","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.jhin.2013.09.010","article-title":"Association between healthcare water systems and Pseudomonas aeruginosa infections: a rapid systematic review","volume":"86","author":"Loveday","year":"2014","journal-title":"J Hosp Infect"},{"key":"B11","doi-asserted-by":"publisher","first-page":"2992","DOI":"10.3390\/microorganisms11122992","article-title":"The presence of Legionella in water used for car washing: implications for public health","volume":"11","author":"Lagan\u00e0","year":"2023","journal-title":"Microorganisms"},{"key":"B12","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1186\/s12903-023-02885-4","article-title":"Bacterial biofilm prevalence in dental unit waterlines: a systematic review and meta-analysis","volume":"23","author":"Bayani","year":"2023","journal-title":"BMC Oral Health"},{"key":"B13","doi-asserted-by":"publisher","first-page":"S437","DOI":"10.1016\/j.identj.2024.07.1269","article-title":"Dental unit waterlines: disinfection and management","volume":"74","author":"Samaranayake","year":"2024","journal-title":"Int Dent J"},{"key":"B14","doi-asserted-by":"publisher","first-page":"255","DOI":"10.3390\/microorganisms10020255","article-title":"Legionella pneumophila\u2014virulence factors and the possibility of infection in dental practice","volume":"10","author":"Talapko","year":"2022","journal-title":"Microorganisms"},{"key":"B15","doi-asserted-by":"publisher","first-page":"3363","DOI":"10.1128\/AEM.66.8.3363-3367.2000","article-title":"Microbial biofilm formation and contamination of dental-unit water systems in general dental practice","volume":"66","author":"Walker","year":"2000","journal-title":"Appl Environ Microbiol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1556\/EuJMI.3.2013.1.7","article-title":"Microbial contamination of dental unit waterlines in dental practices in Hesse, Germany: a cross-sectional study","volume":"3","author":"Arvand","year":"2013","journal-title":"Eur J Microbiol Immunol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1128\/CMR.12.1.147","article-title":"Antiseptics and disinfectants: activity, action, and resistance","volume":"12","author":"McDonnell","year":"1999","journal-title":"Clin Microbiol Rev"},{"key":"B18","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1016\/j.jdent.2007.01.001","article-title":"Optimisation of the long-term efficacy of dental chair waterline disinfection by the identification and rectification of factors associated with waterline disinfection failure","volume":"35","author":"O\u2019Donnell","year":"2007","journal-title":"J Dent"},{"key":"B19","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1289\/ehp.1408692","article-title":"Epidemiology and ecology of opportunistic premise plumbing pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa","volume":"123","author":"Falkinham","year":"2015","journal-title":"Environ Health Perspect"},{"key":"B20","doi-asserted-by":"publisher","first-page":"532","DOI":"10.2166\/wh.2019.240","article-title":"Colonization by Pseudomonas aeruginosa of dental unit waterlines and its relationship with other bacteria: suggestions for microbiological monitoring","volume":"17","author":"Ditommaso","year":"2019","journal-title":"J Water Health"},{"key":"B21","first-page":"1","article-title":"Guidelines for infection control in dental health-care settings\u20132003","volume":"52","author":"Kohn","year":"2003","journal-title":"MMWR Recomm Rep"},{"key":"B22","author":"Halabi","year":""},{"key":"B23","author":"Wien","year":""},{"key":"B24","doi-asserted-by":"publisher","first-page":"129420","DOI":"10.1016\/j.jhazmat.2022.129420","article-title":"Kinetics and mechanism of the reaction of hydrogen peroxide with hypochlorous acid: implication on electrochemical water treatment","volume":"438","author":"Lu","year":"2022","journal-title":"J Hazard Mater"},{"key":"B25","doi-asserted-by":"publisher","first-page":"6551","DOI":"10.1016\/j.atmosenv.2008.04.029","article-title":"Hydroxyl radical from the reaction between hypochlorite and hydrogen peroxide","volume":"42","author":"Castagna","year":"2008","journal-title":"Atmos Environ"},{"key":"B26","doi-asserted-by":"publisher","first-page":"305","DOI":"10.3390\/pathogens9040305","article-title":"Prevention and control of Legionella and Pseudomonas spp. colonization in dental units","volume":"9","author":"Tuvo","year":"2020","journal-title":"Pathogens"},{"key":"B27","doi-asserted-by":"publisher","first-page":"1908","DOI":"10.3389\/fmicb.2019.01908","article-title":"Discovery and therapeutic targeting of differentiated biofilm subpopulations","volume":"10","author":"Bisht","year":"2019","journal-title":"Front Microbiol"},{"key":"B28","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1080\/13102818.2017.1290549","article-title":"Legionella Pneumophila antibodies in serum samples from medical and dental personnel: a seroepidemiological survey","volume":"31","author":"Kevorkyan","year":"2017","journal-title":"Biotechnol Biotechnol Equip"}],"container-title":["Frontiers in Oral Health"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/froh.2026.1903381\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T04:21:16Z","timestamp":1786422076000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/froh.2026.1903381\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,11]]},"references-count":28,"alternative-id":["10.3389\/froh.2026.1903381"],"URL":"https:\/\/doi.org\/10.3389\/froh.2026.1903381","relation":{"has-part":[{"id-type":"doi","id":"https:\/\/doi.org\/10.3389\/froh.2026.1903381.s001","asserted-by":"subject"}]},"ISSN":["2673-4842"],"issn-type":[{"value":"2673-4842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,11]]},"article-number":"1903381"}}