{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T13:24:31Z","timestamp":1788355471684,"version":"build-2803163510"},"reference-count":25,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Transplant."],"abstract":"<jats:p>Machine perfusion is reshaping liver transplantation by turning preservation from passive storage into an active, physiologic intervention. This review synthesizes randomized and real-world evidence on hypothermic oxygenated and normothermic approaches and translates these data into practical guidance for training programs. Across studies, hypothermic oxygenated perfusion reduces ischemic biliary injury, especially in donation after circulatory death, while normothermic perfusion lowers early biochemical injury, decreases early allograft dysfunction, and increases organ utilization through ex situ viability testing. Contemporary cohorts show that \u201cback-to-base\u201d workflows can lessen early complications without increasing ninety-day costs, and that extended preservation, often paired with donor-care unit models, shifts many cases into planned daytime surgery. These operational gains matter for education: daytime cases enable rested faculty, deliberate practice, and graded autonomy. Perfusion broadens the case mix, and the pump itself introduces teachable competencies in setup, troubleshooting, and data-driven accept or decline decisions. Challenges include potential erosion of donor procurement experience, uneven access, and a still-evolving science of viability. We propose a competency-based curriculum spanning setup and safety, physiology, assessment and decision-making, and systems leadership, and outline research priorities as an area of inquiry for future transplantation surgeon-scientists in their training. Aligning training with this platform will improve care and strengthen the transplant workforce.<\/jats:p>","DOI":"10.3389\/frtra.2026.1736191","type":"journal-article","created":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T07:45:50Z","timestamp":1770623150000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Machine perfusion for liver transplantation: opportunities and challenges for the next generation of transplant surgeons"],"prefix":"10.3389","volume":"5","author":[{"given":"Cody L.","family":"Mullens","sequence":"first","affiliation":[{"name":"Department of Surgery, University of Michigan","place":["Ann Arbor, MI,, United States"]},{"name":"Center for Healthcare Outcomes and Policy, University of Michigan","place":["Ann Arbor, MI,, United States"]},{"name":"UM National Clinician Scholars Program, University of Michigan","place":["Ann Arbor, MI,, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kumaran","family":"Shanmugarajah","sequence":"additional","affiliation":[{"name":"Department of Surgery, University of Chicago","place":["Chicago, IL,, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Glenn K.","family":"Wakam","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Transplant and Hepatobiliary Surgery, University of California San Diego","place":["La Jolla, CA,, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,2,9]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1038\/s41575-021-00557-8","article-title":"Machine perfusion of the liver: applications in transplantation and beyond","volume":"19","author":"Ceresa","year":"2022","journal-title":"Nat Rev Gastroenterol Hepatol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1056\/NEJMoa2031532","article-title":"Hypothermic machine perfusion in liver transplantation\u2014a randomized trial","volume":"384","author":"Van Rijn","year":"2021","journal-title":"N Engl J Med"},{"key":"B3","doi-asserted-by":"publisher","first-page":"909","DOI":"10.3390\/jcm12030909","article-title":"Introducing machine perfusion into routine clinical practice for liver transplantation in the United States: the moment has finally come","volume":"12","author":"Croome","year":"2023","journal-title":"J Clin Med"},{"key":"B4","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1097\/SLA.0000000000006634","article-title":"Normothermic liver machine perfusion at a large European center: real-world outcomes following 238 applications","volume":"281","author":"Krendl","year":"2025","journal-title":"Ann Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1038\/s41586-018-0047-9","article-title":"A randomized trial of normothermic preservation in liver transplantation","volume":"557","author":"Nasralla","year":"2018","journal-title":"Nature"},{"key":"B6","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.jamcollsurg.2021.04.032","article-title":"Transplant surgery pipeline: a report from the American society of transplant surgeons pipeline taskforce","volume":"233","author":"Quillin","year":"2021","journal-title":"J Am Coll Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"S712","DOI":"10.1016\/j.ajt.2025.07.1678","article-title":"Reassessment of biomarkers and acceptance criteria in normothermic machine perfusion for liver allografts","volume":"25","author":"Savsani","year":"2025","journal-title":"Am J Transplant"},{"key":"B8","doi-asserted-by":"publisher","first-page":"S215","DOI":"10.1016\/j.ajt.2025.07.472","article-title":"A novel risk score using fFlavin mononucleotide (FMN) for predicting graft loss after liver transplantation with normothermic machine perfusion","volume":"25","author":"Satish","year":"2025","journal-title":"Am J Transplant"},{"key":"B9","doi-asserted-by":"publisher","first-page":"102411","DOI":"10.1016\/j.eclinm.2023.102411","article-title":"Prolonged hypothermic machine perfusion enables daytime liver transplantation\u2014an IDEAL stage 2 prospective clinical trial","volume":"68","author":"Br\u00fcggenwirth","year":"2024","journal-title":"eClinicalMedicine"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1296","DOI":"10.1111\/ajt.15129","article-title":"Organ procurement center allows for daytime liver transplantation with less resource utilization: may address burnout, pipeline, and safety for field of transplantation","volume":"19","author":"Lindemann","year":"2019","journal-title":"Am J Transplant"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1111\/ajt.16899","article-title":"Abdominal normothermic regional perfusion in controlled donation after circulatory determination of death liver transplantation: outcomes and risk factors for graft loss","volume":"22","author":"Hessheimer","year":"2022","journal-title":"Am J Transplant"},{"key":"B12","doi-asserted-by":"publisher","first-page":"CD014685","DOI":"10.1002\/14651858.CD014685.pub2","article-title":"Machine perfusion in liver transplantation","volume":"2023","author":"Tingle","year":"2023","journal-title":"Cochrane Database Syst Rev"},{"key":"B13","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1001\/jamasurg.2021.6781","article-title":"Impact of portable normothermic blood-based machine perfusion on outcomes of liver transplant: the OCS liver PROTECT randomized clinical trial","volume":"157","author":"Markmann","year":"2022","journal-title":"JAMA Surg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1001\/jamasurg.2024.6520","article-title":"Improved outcomes and resource use with normothermic machine perfusion in liver transplantation","volume":"160","author":"Nguyen","year":"2025","journal-title":"JAMA Surg"},{"key":"B15","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1001\/jamasurg.2024.0520","article-title":"US Liver transplant outcomes after normothermic regional perfusion vs standard super rapid recovery","volume":"159","author":"Brubaker","year":"2024","journal-title":"JAMA Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jhep.2024.06.035","article-title":"Long-term outcomes after hypothermic oxygenated machine perfusion and transplantation of 1,202 donor livers in a real-world setting (HOPE-REAL study)","volume":"82","author":"Eden","year":"2025","journal-title":"J Hepatol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1097\/SLA.0000000000006291","article-title":"Impact of back-to-base normothermic machine perfusion on complications and costs: a multicenter, real-world risk-matched analysis","volume":"280","author":"Wehrle","year":"2024","journal-title":"Ann Surg"},{"key":"B18","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1097\/SLA.0000000000006462","article-title":"Revolutionizing liver transplantation: transitioning to an elective procedure through ex situ normothermic machine perfusion\u2014a benefit analysis","volume":"280","author":"Li","year":"2024","journal-title":"Ann Surg"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.1097\/TP.0000000000002533","article-title":"Deceased brain dead donor liver transplantation and utilization in the United States: nighttime and weekend effects","volume":"103","author":"Carpenter","year":"2019","journal-title":"Transplantation"},{"key":"B20","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1007\/s40719-022-00249-x","article-title":"Addressing surgeon burnout through a multi-level approach: a national call to action","volume":"9","author":"Golisch","year":"2023","journal-title":"Curr Trauma Rep"},{"key":"B21","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1097\/LVT.0000000000000560","article-title":"Transforming the logistics of liver transplantation with normothermic machine perfusion: clinical impact versus cost","volume":"31","author":"Gao","year":"2025","journal-title":"Liver Transpl"},{"key":"B22","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1111\/j.1600-6143.2010.03308.x","article-title":"Transplant surgery fellow perceptions about training and the ensuing job market\u2014are the right number of surgeons being trained?","volume":"11","author":"Reich","year":"2011","journal-title":"Am J Transplant"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1002\/lt.26461","article-title":"Donation after circulatory death transplant outcomes using livers recovered by local surgeons","volume":"28","author":"Jadlowiec","year":"2022","journal-title":"Liver Transpl"},{"key":"B24","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.1097\/TP.0000000000004263","article-title":"Predicting early allograft function after normothermic machine perfusion","volume":"106","author":"Watson","year":"2022","journal-title":"Transplantation"},{"key":"B25","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1038\/s41587-019-0374-x","article-title":"An integrated perfusion machine preserves injured human livers for 1 week","volume":"38","author":"Eshmuminov","year":"2020","journal-title":"Nat Biotechnol"}],"container-title":["Frontiers in Transplantation"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frtra.2026.1736191\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T10:00:04Z","timestamp":1771927204000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frtra.2026.1736191\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,9]]},"references-count":25,"alternative-id":["10.3389\/frtra.2026.1736191"],"URL":"https:\/\/doi.org\/10.3389\/frtra.2026.1736191","relation":{},"ISSN":["2813-2440"],"issn-type":[{"value":"2813-2440","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,9]]},"article-number":"1736191"}}