{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T22:47:39Z","timestamp":1789685259397,"version":"4.0.1"},"reference-count":24,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T00:00:00Z","timestamp":1715644800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:p>Wearable sensors like inertial measurement units (IMUs), and those available as smartphone or smartwatch applications, are increasingly used to quantify lumbar mobility. Currently, wearable sensors have to be placed on the back to measure lumbar mobility, meaning it cannot be used in unsupervised environments. This study aims to compare lumbar sagittal plane angles quantified from a wrist-worn against that of a lumbar-worn sensor. Twenty healthy participants were recruited. An IMU was placed on the right wrist and the L3 spinal level. Participants had to position their right forearm on their abdomen, parallel to the floor. Three sets of three consecutive repetitions of flexion, and extension were formed. Linear mixed models were performed to quantify the effect of region (lumbar vs. wrist) on six outcomes [minimum, maximum, range of motion (ROM) of flexion and extension]. Only flexion ROM was significantly different between the wrist and lumbar sensors, with a mean of 4.54\u00b0 (95% CI\u2009=\u20091.82\u00b0\u20137.27\u00b0). Across all outcomes, the maximal difference between a wrist-worn and lumbar-worn sensor was &amp;lt;8\u00b0. A wrist-worn IMU sensor could be used to measure gross lumbar sagittal plane mobility in place of a lumbar-worn IMU. This may be useful for remote monitoring during rehabilitation.<\/jats:p>","DOI":"10.3389\/fspor.2024.1381020","type":"journal-article","created":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T04:56:56Z","timestamp":1715662616000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Quantifying lumbar sagittal plane kinematics using a wrist-worn inertial measurement unit"],"prefix":"10.3389","volume":"6","author":[{"given":"Bernard X. W.","family":"Liew","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oscar","family":"Crisafulli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David W.","family":"Evans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,5,14]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1136\/oemed-2013-101862","article-title":"Cumulative mechanical low-back load at work is a determinant of low-back pain","volume":"71","author":"Coenen","year":"2014","journal-title":"Occup Environ Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.apmr.2017.08.493","article-title":"Psychological features and their relationship to movement-based subgroups in people living with low back pain","volume":"99","author":"Karayannis","year":"2018","journal-title":"Arch Phys Med Rehabil"},{"key":"B3","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/1471-2474-13-24","article-title":"Physiotherapy movement based classification approaches to low back pain: comparison of subgroups through review and developer\/expert survey","volume":"13","author":"Karayannis","year":"2012","journal-title":"BMC Musculoskelet Disord"},{"key":"B4","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1016\/j.bjpt.2017.08.001","article-title":"Diagnosis and treatment of movement system impairment syndromes","volume":"21","author":"Sahrmann","year":"2017","journal-title":"Braz J Phys Ther"},{"key":"B5","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1093\/ptj\/pzy022","article-title":"Cognitive functional therapy: an integrated behavioral approach for the targeted management of disabling low back pain","volume":"98","author":"O\u2019Sullivan","year":"2018","journal-title":"Phys Ther"},{"key":"B6","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1136\/bjsports-2016-097327","article-title":"Mckenzie method of mechanical diagnosis and therapy was slightly more effective than placebo for pain, but not for disability, in patients with chronic non-specific low back pain: a randomised placebo controlled trial with short and longer term follow-up","volume":"52","author":"Garcia","year":"2018","journal-title":"Br J Sports Med"},{"key":"B7","doi-asserted-by":"publisher","first-page":"802350","DOI":"10.1155\/2012\/802350","article-title":"Measurement of intervertebral motion using quantitative fluoroscopy: report of an international forum and proposal for use in the assessment of degenerative disc disease in the lumbar spine","volume":"2012","author":"Breen","year":"2012","journal-title":"Adv Orthop"},{"key":"B8","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/j.gaitpost.2008.05.005","article-title":"The in vivo three-dimensional motion of the human lumbar spine during gait","volume":"28","author":"Rozumalski","year":"2008","journal-title":"Gait Posture"},{"key":"B9","doi-asserted-by":"publisher","first-page":"110217","DOI":"10.1016\/j.jbiomech.2020.110217","article-title":"Effects of spinal coupling and marker set on tracking of spine models during running","volume":"116","author":"Glover","year":"2021","journal-title":"J Biomech"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2406","DOI":"10.1016\/j.jbiomech.2009.06.024","article-title":"Optimal inertial sensor location for ambulatory measurement of trunk inclination","volume":"42","author":"Faber","year":"2009","journal-title":"J Biomech"},{"key":"B11","doi-asserted-by":"publisher","first-page":"490","DOI":"10.3390\/diagnostics11030490","article-title":"Measuring spinal mobility using an inertial measurement unit system: a reliability study in axial spondyloarthritis","volume":"11","author":"O'Grady","year":"2021","journal-title":"Diagnostics (Basel)"},{"key":"B12","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.msksp.2017.08.005","article-title":"Within\/between-session reliability and agreement of lumbopelvic kinematics in the sagittal plane during functional movement control tasks in healthy persons","volume":"33","author":"Matheve","year":"2018","journal-title":"Musculoskelet Sci Pract"},{"key":"B13","doi-asserted-by":"publisher","first-page":"e0215806","DOI":"10.1371\/journal.pone.0215806","article-title":"Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: a systematic review","volume":"14","author":"Keogh","year":"2019","journal-title":"PLoS ONE"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1016\/j.jbiomech.2012.12.007","article-title":"Lifting style and participant\u2019s sex do not affect optimal inertial sensor location for ambulatory assessment of trunk inclination","volume":"46","author":"Faber","year":"2013","journal-title":"J Biomech"},{"key":"B15","doi-asserted-by":"publisher","first-page":"e2355","DOI":"10.7717\/peerj.2355","article-title":"Reliability and validity of an iPhone(\u00ae) application for the measurement of lumbar spine flexion and extension range of motion","volume":"4","author":"Pourahmadi","year":"2016","journal-title":"PeerJ (San Francisco, CA)"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1831","DOI":"10.1002\/ejp.1631","article-title":"Movement, posture and low back pain. How do they relate? A replicated single-case design in 12 people with persistent, disabling low back pain","volume":"24","author":"Wernli","year":"2020","journal-title":"Eur J Pain"},{"key":"B17","first-page":"17","author":"Guo","year":"2016"},{"key":"B18","doi-asserted-by":"publisher","first-page":"e110","DOI":"10.2196\/jmir.9157","article-title":"Using fitness trackers and smartwatches to measure physical activity in research: analysis of consumer wrist-worn wearables","volume":"20","author":"Henriksen","year":"2018","journal-title":"J Med Internet Res"},{"key":"B19","doi-asserted-by":"publisher","first-page":"e0183651","DOI":"10.1371\/journal.pone.0183651","article-title":"Method for measuring tri-axial lumbar motion angles using wearable sheet stretch sensors","volume":"12","author":"Yamamoto","year":"2017","journal-title":"PLoS ONE"},{"key":"B20","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.humov.2016.11.005","article-title":"Goal equivalent manifold analysis of task performance in non-specific LBP and healthy subjects during repetitive trunk movement: effect of load, velocity, symmetry","volume":"51","author":"Chehrehrazi","year":"2017","journal-title":"Hum Mov Sci"},{"key":"B21","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1186\/s12891-018-2233-1","article-title":"Subgroups of lumbo-pelvic flexion kinematics are present in people with and without persistent low back pain","volume":"19","author":"Laird","year":"2018","journal-title":"BMC Musculoskelet Disord"},{"key":"B22","doi-asserted-by":"publisher","first-page":"E697","DOI":"10.1097\/01.brs.0000188255.10759.7a","article-title":"Symptomatic and asymptomatic movement coordination of the lumbar spine and hip during an everyday activity","volume":"30","author":"Shum","year":"2005","journal-title":"Spine"},{"key":"B23","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1016\/j.jmpt.2014.10.004","article-title":"Regional lumbar motion and patient-rated outcomes: a secondary analysis of data from a randomized clinical trial","volume":"37","author":"Mieritz","year":"2014","journal-title":"J Manipulative Physiol Ther"},{"key":"B24","doi-asserted-by":"crossref","DOI":"10.1186\/s12891-017-1515-3","article-title":"The effects of bending speed on the lumbo-pelvic kinematics and movement pattern during forward bending in people with and without low back pain","volume":"18","author":"Tsang","year":"2017","journal-title":"BMC Musculoskelet Disord"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2024.1381020\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T04:56:58Z","timestamp":1715662618000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2024.1381020\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,14]]},"references-count":24,"alternative-id":["10.3389\/fspor.2024.1381020"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2024.1381020","relation":{},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,14]]},"article-number":"1381020"}}