{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:14:14Z","timestamp":1790745254953,"version":"4.1.0"},"reference-count":18,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>The present study examined how well different blood flow restriction (BFR) devices deliver the prescribed tourniquet cuff pressure.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Fifteen participants completed four BFR exercise sessions, each with a different BFR device [Delfi Personalized Tourniquet System (PTS) for BFR, Saga, SmartCuffs, and Suji], comprising four sets of unilateral leg press (30-15-15-15 repetitions) against resistance bands with 30-second rest periods. The tourniquet cuff was secured proximally on the exercising leg, and the target pressure was set to 80% limb occlusion pressure (LOP), as measured by the device, applied continuously throughout the exercise\/rest periods. Tourniquet cuff pressure was sampled at 100\u2005Hz via a pressure transducer.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Despite prescribing tourniquet cuff pressure at 80% LOP, the actual pressure can vary substantially and be inconsistent between individuals depending on the BFR device used. During the exercise periods, the median percentage of time pressure was within \u00b110% the target pressure was 95% (Delfi PTS for BFR), 25% (Saga), 26% (SmartCuffs), and 34% (Suji). During the rest periods, the median percentage of time pressure was within \u00b15% the target pressure was 99% (Delfi PTS for BFR), and 0% for the Saga, SmartCuffs, and Suji BFR devices. Tourniquet cuff pressure during BFR exercise behaves in a wave-like manner characterised by cyclical pressure peaks and valleys. The magnitude of pressure peaks and valleys was: Delfi PTS for BFR (89\u2009\u00b1\u20092% and 72\u2009\u00b1\u20093% LOP), Saga (79\u2009\u00b1\u20099 and 58\u2009\u00b1\u20097% LOP), SmartCuffs (79\u2009\u00b1\u20099% and 61\u2009\u00b1\u20097% LOP), and Suji (90\u2009\u00b1\u200915 and 65\u2009\u00b1\u200910% LOP). In several cases, participants experienced tourniquet pressures &amp;gt;100% LOP using the Saga, SmartCuffs, and Suji BFR devices, for up to \u223c30%\u201355% of the exercise set duration. A progressive loss of pressure occurred throughout the BFR application period by an average of 2\u20134\u2005mmHg\u00b7min<jats:sup>\u22121<\/jats:sup> (\u223c1%\u20132% LOP\u00b7min<jats:sup>\u22121<\/jats:sup>) in the Saga, SmartCuffs, and Suji BFR devices, whilst the Delfi PTS for BFR exhibited trivial pressure drifts.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Differences between the actual and prescribed tourniquet cuff pressure can highly depend on the BFR device employed. The selection of the BFR apparatus is thus important to delivering the prescribed tourniquet cuff pressure to allow for standardisation of the relative occlusion pressure between users.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fspor.2025.1582387","type":"journal-article","created":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T10:55:28Z","timestamp":1756896928000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Tourniquet cuff pressure during blood flow restriction exercise"],"prefix":"10.3389","volume":"7","author":[{"given":"Patrick","family":"Swain","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"McEwen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke","family":"Hughes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,9,2]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"533","DOI":"10.3389\/fphys.2019.00533","article-title":"Blood flow restriction exercise: considerations of methodology, application, and safety","volume":"10","author":"Patterson","year":"2019","journal-title":"Front Physiol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"800155","DOI":"10.3389\/fphys.2022.800155","article-title":"Physiological responses to acute cycling with blood flow restriction","volume":"13","author":"Kilgas","year":"2022","journal-title":"Front Physiol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s00421-019-04250-2","article-title":"Knee extension with blood flow restriction: impact of cuff pressure on hemodynamics","volume":"120","author":"Singer","year":"2020","journal-title":"Eur J Appl Physiol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1007\/s00421-018-4029-2","article-title":"Limb blood flow and tissue perfusion during exercise with blood flow restriction","volume":"119","author":"Kilgas","year":"2019","journal-title":"Eur J Appl Physiol"},{"key":"B5","doi-asserted-by":"publisher","first-page":"136","DOI":"10.70252\/RWVU7100","article-title":"The effect of cuff width for determining limb occlusion pressure: a comparison of blood flow restriction devices","volume":"12","author":"Weatherholt","year":"2019","journal-title":"Int J Exerc Sci"},{"key":"B6","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1007\/s00421-014-3030-7","article-title":"Blood flow restriction in the upper and lower limbs is predicted by limb circumference and systolic blood pressure","volume":"115","author":"Loenneke","year":"2015","journal-title":"Eur J Appl Physiol"},{"key":"B7","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1007\/s40846-018-0397-7","article-title":"Why is it crucial to use personalized occlusion pressures in blood flow restriction (BFR) rehabilitation?","volume":"39","author":"Mcewen","year":"2019","journal-title":"J Med Biol Eng"},{"key":"B8","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1519\/JSC.0000000000003525","article-title":"Blood flow restricted exercise and discomfort: a review","volume":"36","author":"Spitz","year":"2022","journal-title":"J Strength Cond Res"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1111\/sms.13092","article-title":"Interface pressure, perceptual, and mean arterial pressure responses to different blood flow restriction systems","volume":"28","author":"Hughes","year":"2018","journal-title":"Scand J Med Sci Sports"},{"key":"B10","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.ptsp.2024.02.001","article-title":"It\u2019s time to regulate\u2013the importance of accurate surgical-grade tourniquet autoregulation in blood flow restriction exercise applications","volume":"67","author":"Hughes","year":"2024","journal-title":"Phys Ther Sport"},{"key":"B11","doi-asserted-by":"publisher","first-page":"e4697","DOI":"10.7717\/peerj.4697","article-title":"Influence and reliability of lower-limb arterial occlusion pressure at different body positions","volume":"6","author":"Hughes","year":"2018","journal-title":"PeerJ"},{"key":"B12","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1136\/bjsports-2024-109365","article-title":"Blood flow restriction: methods and apparatus still matter","volume":"59","author":"Hughes","year":"2025","journal-title":"Br J Sports Med."},{"key":"B13","article-title":"joyPlot\u2014Ridgeline Data Representation","author":"Benito","year":"2024"},{"key":"B14","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1111\/cpf.12246","article-title":"Blood flow occlusion pressure at rest and immediately after a bout of low load exercise","volume":"36","author":"Barnett","year":"2016","journal-title":"Clin Physiol Funct Imaging"},{"key":"B15","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s42490-021-00053-9","article-title":"Investigation of clinically acceptable agreement between two methods of automatic measurement of limb occlusion pressure: a randomised trial","volume":"3","author":"Hughes","year":"2021","journal-title":"BMC Biomed Eng"},{"key":"B16","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1007\/s40846-016-0173-5","article-title":"Technique for measuring limb occlusion pressure that facilitates personalized tourniquet systems: a randomized trial","volume":"36","author":"Masri","year":"2016","journal-title":"J Med Biol Eng"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1404247","DOI":"10.3389\/fphys.2024.1404247","article-title":"Validity and reliability of a wearable blood flow restriction training device for arterial occlusion pressure assessment","volume":"15","author":"Zhang","year":"2024","journal-title":"Front Physiol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"e1127","DOI":"10.1016\/j.asmr.2022.04.002","article-title":"An automated technique for the measurement of limb occlusion pressure during blood flow restriction therapy is equivalent to previous gold standard","volume":"4","author":"Abbas","year":"2022","journal-title":"Arthrosc Sports Med Rehabil"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1582387\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T10:55:29Z","timestamp":1756896929000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1582387\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,2]]},"references-count":18,"alternative-id":["10.3389\/fspor.2025.1582387"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2025.1582387","relation":{},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,2]]},"article-number":"1582387"}}