{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T02:28:06Z","timestamp":1793500086433,"version":"4.5.0"},"reference-count":68,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>In intermittent sports, available internal load measurements like capillary blood techniques and portable respiratory gas analyzers are considered as gold standards in controlled laboratory environments, but are impractical for daily use in training and matches. A newer approach, the metabolic power model, allows to extrapolate from speed and acceleration data to the metabolic power, simulated oxygen uptake, and aerobic and anaerobic energy supply. The aim of this study was to validate the metabolic power model against the established 3-component model to allow direct comparison of variables including energy expenditure and supplies during intermittent running-based exercises.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Twelve male athletes (24\u2009\u00b1\u20093 years) performed three different running-based exercises consisting of continuous shuttle runs and repeated accelerations and sprints with change of direction. Each exercise condition intended to primarily stress the aerobic, anaerobic alactic, and lactic energy supply. One-way repeated measures ANOVA or Friedman test and corresponding effect sizes were applied for statistical analyses. Additionally, absolute and relative biases and Bland-Altman plots were generated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>For total energy expenditure, there were statistically significant differences (<jats:italic>p<\/jats:italic>\u2009\u2264\u2009.002, <jats:italic>d<\/jats:italic>\u2009\u2265\u2009.882, large) and biases of \u221213.5\u2009\u00b1\u200911.8% for the continuous shuttle runs and up to 352.2\u2009\u00b1\u2009115.9% for repeated accelerations and sprints. Concerning aerobic energy supply, there were statistically significant differences (<jats:italic>p<\/jats:italic>\u2009&amp;lt;\u2009.001, <jats:italic>d<\/jats:italic>\u2009\u2265\u20091.937, large effect sizes) and biases of up to \u221238.1\u2009\u00b1\u200911.7%. For anaerobic energy supply, there were statistically significant differences (<jats:italic>p<\/jats:italic>\u2009&amp;lt;\u2009.001, <jats:italic>d<\/jats:italic>\u2009\u2265\u20095.465, large) and biases of up to 1,849.9\u2009\u00b1\u2009831.8%.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>In conclusion, the metabolic power model significantly under- or overestimates total energy expenditure and supplies with large effect sizes during intermittent running-based exercises. Future studies should optimize the model before it can be used on a daily basis for scientific and practical purposes.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fspor.2025.1583313","type":"journal-article","created":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T05:23:37Z","timestamp":1744867417000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Validation of the metabolic power model during three intermittent running-based exercises with emphasis on aerobic and anaerobic energy supply"],"prefix":"10.3389","volume":"7","author":[{"given":"Joana","family":"Brochhagen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias W.","family":"Hoppe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,4,17]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"2721","DOI":"10.3390\/ijerph18052721","article-title":"Load measures in training\/match monitoring in soccer: a systematic review","volume":"18","author":"Miguel","year":"2021","journal-title":"Int J Environ Res Public Health"},{"key":"B2","first-page":"43","article-title":"Molecular-biological basis of muscular performance and fitness","volume":"54","author":"Fl\u00fcck","year":"2006","journal-title":"Schweiz Z Sportmed Sporttraum"},{"key":"B3","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1123\/ijspp.2018-0935","article-title":"Internal and external training load: 15 years on","volume":"14","author":"Impellizzeri","year":"2019","journal-title":"Int J Sports Physiol Perform"},{"key":"B4","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1249\/MSS.0b013e3181ae5cfd","article-title":"Energy cost and metabolic power in elite soccer: a new match analysis approach","volume":"42","author":"Osgnach","year":"2010","journal-title":"Med Sci Sports Exerc"},{"key":"B5","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1177\/1754337120988236","article-title":"Comparison of the validity and reliability of local positioning systems against other tracking technologies in team sports: a systematic review","volume":"236","author":"Pino-Ortega","year":"2022","journal-title":"Proc Inst Mech Eng Part P"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1519\/JSC.0000000000001221","article-title":"The validity and reliability of global positioning systems in team sport: a brief review","volume":"30","author":"Scott","year":"2016","journal-title":"J Strength Cond Res"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.3390\/s21041465","article-title":"Validation of player and ball tracking with a local positioning system","volume":"21","author":"Blauberger","year":"2021","journal-title":"Sensors (Basel)"},{"key":"B8","doi-asserted-by":"publisher","first-page":"228","DOI":"10.3389\/fphys.2018.00228","article-title":"Validity and reliability of 10-Hz global positioning system to assess in-line movement and change of direction","volume":"9","author":"Nikolaidis","year":"2018","journal-title":"Front Physiol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"e0192708","DOI":"10.1371\/journal.pone.0192708","article-title":"Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports","volume":"13","author":"Hoppe","year":"2018","journal-title":"PLoS One"},{"key":"B10","doi-asserted-by":"publisher","first-page":"6336","DOI":"10.1038\/s41598-020-63297-w","article-title":"New insights into mechanical, metabolic and muscle oxygenation signals during and after high-intensity tethered running","volume":"10","author":"Manchado-Gobatto","year":"2020","journal-title":"Sci Rep"},{"key":"B11","doi-asserted-by":"publisher","first-page":"S19","DOI":"10.1055\/s-2004-830507","article-title":"Ambulatory gas exchange measurements\u2014current status and future options","volume":"26","author":"Meyer","year":"2005","journal-title":"Int J Sports Med"},{"key":"B12","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1055\/s-0034-1366540","article-title":"Intraobserver reliability of the handball-specific complex test (HBKT)","volume":"28","author":"Schwesig","year":"2014","journal-title":"Sportverletz Sportschaden"},{"key":"B13","doi-asserted-by":"publisher","first-page":"2809","DOI":"10.1242\/jeb.01700","article-title":"Sprint running: a new energetic approach","volume":"208","author":"di Prampero","year":"2005","journal-title":"J Exp Biol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1055\/a-0592-7660","article-title":"Metabolic power in team sports\u2014part 1: an update","volume":"39","author":"di Prampero","year":"2018","journal-title":"Int J Sports Med"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1152\/japplphysiol.01177.2001","article-title":"Energy cost of walking and running at extreme uphill and downhill slopes","volume":"93","author":"Minetti","year":"2002","journal-title":"J Appl Physiol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1123\/ijspp.2015-0566","article-title":"Concurrent validity of GPS for deriving mechanical properties of pprint acceleration","volume":"12","author":"Nagahara","year":"2017","journal-title":"Int J Sports Physiol Perform"},{"key":"B17","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1123\/ijspp.2018-0661","article-title":"Metabolic power: a step in the right direction for team sports","volume":"14","author":"Polglaze","year":"2019","journal-title":"Int J Sports Physiol Perform"},{"key":"B18","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1055\/a-0592-7219","article-title":"Metabolic power in team sports\u2014part 2: aerobic and anaerobic energy yields","volume":"39","author":"Osgnach","year":"2018","journal-title":"Int J Sports Med"},{"key":"B19","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1186\/s40798-022-00525-9","article-title":"Metabolic power in team and racquet sports: a systematic review with best-evidence synthesis","volume":"8","author":"Brochhagen","year":"2022","journal-title":"Sports Med Open"},{"key":"B20","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1123\/ijspp.2016-0160","article-title":"Evaluation of the match external load in soccer: methods comparison","volume":"12","author":"Castagna","year":"2017","journal-title":"Int J Sports Physiol Perform"},{"key":"B21","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1515\/hukin-2017-0083","article-title":"Variability of metabolic power data in elite soccer players during pre-season matches","volume":"58","author":"Hoppe","year":"2017","journal-title":"J Hum Kinet"},{"key":"B22","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1519\/jsc.0000000000000239","article-title":"Aerobic fitness ecological validity in elite soccer players: a metabolic power approach","volume":"28","author":"Manzi","year":"2014","journal-title":"J Strength Cond Res"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.23736\/s0022-4707.17.07563-6","article-title":"The use of metabolic power to assess physical demands in soccer: how does it differ from the traditional approach through speed running?","volume":"58","author":"Mart\u00ednez-Cabrera","year":"2018","journal-title":"J Sports Med Phys Fitness"},{"key":"B24","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1055\/a-1165-1916","article-title":"Monitoring matches and small-sided games in elite young soccer players","volume":"41","author":"Darbellay","year":"2020","journal-title":"Int J Sports Med"},{"key":"B25","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1055\/s-0033-1355418","article-title":"Systematic bias between running speed and metabolic power data in elite soccer players: influence of drill type","volume":"35","author":"Gaudino","year":"2014","journal-title":"Int J Sports Med"},{"key":"B26","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1123\/pes.2018-0122","article-title":"High-intensity demands of 6-a-side small-sided games and 11-a-side matches in youth soccer players","volume":"31","author":"Goto","year":"2019","journal-title":"Pediatr Exerc Sci"},{"key":"B27","doi-asserted-by":"publisher","first-page":"44","DOI":"10.3390\/sports6020044","article-title":"The validity of external: internal training load ratios in rested and fatigued soccer players","volume":"6","author":"Akubat","year":"2018","journal-title":"Sports"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1055\/s-0035-1555927","article-title":"Monitoring locomotor load in soccer: is metabolic power, powerful?","volume":"36","author":"Buchheit","year":"2015","journal-title":"Int J Sports Med"},{"key":"B29","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.jsams.2017.03.013","article-title":"Energy expenditure, metabolic power and high speed activity during linear and multi-directional running","volume":"20","author":"Oxendale","year":"2017","journal-title":"J Sci Med Sport"},{"key":"B30","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1249\/mss.0000000000000515","article-title":"Measured and estimated energy cost of constant and shuttle running in soccer players","volume":"47","author":"Stevens","year":"2015","journal-title":"Med Sci Sports Exerc"},{"key":"B31","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1123\/ijspp.2016-0021","article-title":"Metabolic power method: underestimation of energy expenditure in field-sport movements using a global positioning system tracking system","volume":"11","author":"Brown","year":"2016","journal-title":"Int J Sports Physiol Perform"},{"key":"B32","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1123\/ijspp.2016-0069","article-title":"The unsuitability of energy expenditure derived from microtechnology for assessing internal load in collision-based activities","volume":"12","author":"Highton","year":"2017","journal-title":"Int J Sports Physiol Perform"},{"key":"B33","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1123\/ijspp.2021-0451","article-title":"Defining training and performance caliber: a participant classification framework","volume":"17","author":"McKay","year":"2022","journal-title":"Int J Sports Physiol Perform"},{"key":"B34","doi-asserted-by":"publisher","first-page":"e0199985","DOI":"10.1371\/journal.pone.0199985","article-title":"Table tennis playing styles require specific energy systems demands","volume":"13","author":"Milioni","year":"2018","journal-title":"PLoS One"},{"key":"B35","first-page":"219","article-title":"The relationship between the interval shuttle run test and maximal oxygen uptake in soccer players","volume":"45","author":"Lemmink","year":"2003","journal-title":"J Hum Mov Stud"},{"key":"B36","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1519\/13993.1","article-title":"The interval shuttle run test for intermittent sport players: evaluation of reliability","volume":"18","author":"Lemmink","year":"2004","journal-title":"J Strength Cond Res"},{"key":"B37","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1519\/JSC.0b013e31824e1711","article-title":"Comparison between three different endurance tests in professional soccer players","volume":"27","author":"Hoppe","year":"2013","journal-title":"J Strength Cond Res"},{"key":"B38","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1249\/MSS.0000000000003023","article-title":"Reference standards for peak rating of perceived exertion during cardiopulmonary exercise testing: data from FRIEND","volume":"55","author":"Peterman","year":"2023","journal-title":"Med Sci Sports Exerc"},{"key":"B39","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1007\/s00421-002-0622-4","article-title":"How anaerobic is the wingate anaerobic test for humans?","volume":"87","author":"Beneke","year":"2002","journal-title":"Eur J Appl Physiol"},{"key":"B40","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1055\/s-2006-924340","article-title":"Validity of simple field tests as indicators of match-related physical performance in top-level professional soccer players","volume":"28","author":"Rampinini","year":"2007","journal-title":"Int J Sports Med"},{"key":"B41","volume-title":"Physiology of Sport and Exercise","author":"Kenney","year":"2020"},{"key":"B42","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1002\/9780470757277.ch2","article-title":"Metabolism during exercise\u2014energy expenditure and hormonal changes","volume-title":"Textbook of Sports Medicine","author":"Henriksson","year":"2003"},{"key":"B43","doi-asserted-by":"publisher","first-page":"e14490","DOI":"10.1111\/sms.14490","article-title":"Accuracy of respiratory gas variables, substrate, and energy use from 15 CPET systems during simulated and human exercise","volume":"34","author":"Van Hooren","year":"2024","journal-title":"Scand J Med Sci Sports"},{"key":"B44","doi-asserted-by":"publisher","first-page":"S218","DOI":"10.1123\/ijspp.2016-0236","article-title":"Unpacking the black box: applications and considerations for using GPS devices in sport","volume":"12","author":"Malone","year":"2017","journal-title":"Int J Sports Physiol Perform"},{"key":"B45","doi-asserted-by":"publisher","first-page":"2463","DOI":"10.1007\/s40279-023-01903-3","article-title":"Data processing strategies to determine maximum oxygen uptake: a systematic scoping review and experimental comparison with guidelines for reporting","volume":"53","author":"Nolte","year":"2023","journal-title":"Sports Med"},{"key":"B46","doi-asserted-by":"publisher","first-page":"95","DOI":"10.2165\/11319670-000000000-00000","article-title":"Recommendations for improved data processing from expired gas analysis indirect calorimetry","volume":"40","author":"Robergs","year":"2010","journal-title":"Sports Med"},{"key":"B47","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1055\/s-0042-117722","article-title":"Energy systems contribution in the running-based anaerobic sprint test","volume":"38","author":"Milioni","year":"2017","journal-title":"Int J Sports Med"},{"key":"B48","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1123\/ijspp.2015-0746","article-title":"Energetics of table tennis and table tennis-specific exercise testing","volume":"11","author":"Zagatto","year":"2016","journal-title":"Int J Sports Physiol Perform"},{"key":"B49","volume-title":"Studien zu Einer Physiologie des Marsches","author":"Zuntz","year":"1901"},{"key":"B50","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/s0034-5687(99)00083-3","article-title":"The energetics of anaerobic muscle metabolism: a reappraisal of older and recent concepts","volume":"118","author":"di Prampero","year":"1999","journal-title":"Respir Physiol"},{"key":"B51","volume-title":"Statistical Power Analysis for the Behavioral Sciences","author":"Cohen","year":"1988"},{"key":"B52","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1123\/ijspp.2017-0174","article-title":"Energetic profile of the basketball exercise simulation test in junior elite players","volume":"13","author":"Latzel","year":"2018","journal-title":"Int J Sports Physiol Perform"},{"key":"B53","doi-asserted-by":"publisher","first-page":"621","DOI":"10.3390\/oxygen2040042","article-title":"Pros and cons of two methods of anaerobic alactic energy assessment in a high-intensity CrossFit\u00ae workout","volume":"2","author":"Rios","year":"2022","journal-title":"Oxygen"},{"key":"B54","doi-asserted-by":"publisher","first-page":"2153","DOI":"10.1007\/s00421-013-2646-3","article-title":"Anaerobic alactic energy assessment in middle distance swimming","volume":"113","author":"Sousa","year":"2013","journal-title":"Eur J Appl Physiol"},{"key":"B55","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.1123\/ijspp.2022-0115","article-title":"Reliability of the 3-component model of aerobic, anaerobic lactic, and anaerobic alactic energy distribution (PCr-LA-O2) for energetic profiling of continuous and intermittent exercise","volume":"17","author":"Kaufmann","year":"2022","journal-title":"Int J Sports Physiol Perform"},{"key":"B56","doi-asserted-by":"publisher","first-page":"163","DOI":"10.3390\/app12010163","article-title":"Comparative analysis of the indirect calorimetry and the metabolic power method to calculate energy expenditure in team handball","volume":"12","author":"Fuchs","year":"2022","journal-title":"Appl Sci"},{"key":"B57","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.jesf.2021.03.003","article-title":"Effects of sprint distance and repetition number on energy system contributions in soccer players","volume":"19","author":"Ulupinar","year":"2021","journal-title":"J Exerc Sci Fit"},{"key":"B58","doi-asserted-by":"publisher","first-page":"313","DOI":"10.2165\/00007256-199927050-00003","article-title":"Oxygen uptake kinetics during exercise","volume":"27","author":"Xu","year":"1999","journal-title":"Sports Med"},{"key":"B59","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.2165\/00007256-200535120-00003","article-title":"Physiological and metabolic responses of repeated-sprint activities:specific to field-based team sports","volume":"35","author":"Spencer","year":"2005","journal-title":"Sports Med"},{"key":"B60","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.1519\/JSC.0000000000000293","article-title":"The influence of soccer playing actions on the recovery kinetics after a soccer match","volume":"28","author":"Nedelec","year":"2014","journal-title":"J Strength Cond Res"},{"key":"B61","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2165\/00007256-200131010-00001","article-title":"The relationship between aerobic fitness and recovery from high intensity intermittent exercise","volume":"31","author":"Tomlin","year":"2001","journal-title":"Sports Med"},{"key":"B62","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/jcm14010021","article-title":"Predicting heart rate at the anaerobic threshold using a machine learning model based on a large-scale population dataset","volume":"14","author":"Nakayama","year":"2024","journal-title":"J Clin Med"},{"key":"B63","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s40798-017-0112-1","article-title":"The maximal oxygen uptake verification phase: a light at the end of the tunnel?","volume":"3","author":"Schaun","year":"2017","journal-title":"Sports Med Open"},{"key":"B64","doi-asserted-by":"publisher","first-page":"725","DOI":"10.2165\/00007256-200131100-00003","article-title":"Energy system interaction and relative contribution during maximal exercise","volume":"31","author":"Gastin","year":"2001","journal-title":"Sports Med"},{"key":"B65","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1111\/j.1469-7793.2001.t01-1-00891.x","article-title":"Influence of exercise intensity on the on- and off-transient kinetics of pulmonary oxygen uptake in humans","volume":"533","author":"\u00d6zyener","year":"2001","journal-title":"J Physiol"},{"key":"B66","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1136\/bjsm.2010.076380","article-title":"Low reproducibility of many lactate markers during incremental cycle exercise","volume":"46","author":"Morton","year":"2012","journal-title":"Br J Sports Med"},{"key":"B67","doi-asserted-by":"publisher","first-page":"1283327","DOI":"10.3389\/fphys.2023.1283327","article-title":"Calculation of a conversion factor for estimating the glycolytic contribution in exercise from post-exercise blood lactate concentration","volume":"14","author":"Hill","year":"2023","journal-title":"Front Physiol"},{"key":"B68","doi-asserted-by":"publisher","first-page":"673","DOI":"10.2165\/11590550-000000000-00000","article-title":"Repeated-sprint ability\u2014part I: factors contributing to fatigue","volume":"41","author":"Girard","year":"2011","journal-title":"Sports Med"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1583313\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T05:23:39Z","timestamp":1744867419000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1583313\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,17]]},"references-count":68,"alternative-id":["10.3389\/fspor.2025.1583313"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2025.1583313","relation":{},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,17]]},"article-number":"1583313"}}