{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T18:02:18Z","timestamp":1790877738079,"version":"4.1.0"},"reference-count":31,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T00:00:00Z","timestamp":1763424000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Body composition is a critical health measure. Accurate monitoring of body composition, such as body fat percentage (BF%) and skeletal muscle mass percentage (SM%), enables individuals to make informed decisions regarding nutrition, exercise, health status and management. Recent advancements have integrated bioelectrical impedance analysis (BIA) into wearable technology, presenting accessible options for tracking body composition measures. However, the validity of wearable BIA devices in comparison to criterion methods remains underexplored. Therefore, this study aimed to assess the validity of a wrist-worn consumer device and a clinical BIA device against the criterion measure of dual-energy x-ray absorptiometry (DXA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This study included 108 physically active participants (56 females, 52 males). Participants underwent assessments using DXA, a wearable smartwatch BIA device (wearable-BIA; Samsung Galaxy Watch5), and a clinical standing hand-to-foot BIA analyzer (clinical-BIA; InBody 770). Measures of interest included BF% and SM%. Data were analyzed for accuracy using tests of error [mean absolute error [MAE], mean absolute percentage error [MAPE]], linearity (Pearson's\n                      <jats:italic>r<\/jats:italic>\n                      , Deming regression), agreement (Lin's CCC), and equivalence, complemented by Bland-Altman plots to visually represent bias.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      When assessing BF%, both the wearable-BIA (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.93; CCC\u2009=\u20090.91) and clinical-BIA (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.96; CCC\u2009=\u20090.86), demonstrated very strong correlations and agreement compared to DXA, with MAPEs of 14.3% and 21.1%, respectively. Female participants using the wearable-BIA device showed the greatest accuracy for BF% (CCC\u2009=\u20090.91, MAPE\u2009=\u20099.19%, equivalence supported). Bland-Altman analysis revealed proportional bias, particularly in individuals with higher BF%. Although correlations were considered strong for SM%, agreement was classified as weak (wearable-BIA:\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.92, CCC\u2009=\u20090.45; MAPE\u2009=\u200920.3%; clinical-BIA,\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.89; CCC\u2009=\u20090.25; MAPE\u2009=\u200936.1%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Both the wearable- and clinical-BIA device revealed mixed validity, demonstrating strong correlations for both BF% and SM%, and high levels of agreement and low error for BF%. Additionally, the wearable-BIA demonstrated acceptable accuracy for estimating BF% in females. However, wider limits of agreement and variability suggest limitations in validity, particularly for skeletal muscle mass and in individuals with higher body fat percentages. These findings support the practical use of wearable devices for general body composition monitoring when laboratory-based methods are unavailable, though caution is warranted. Continued development and validation efforts are recommended to enhance accuracy and consistency across diverse populations and measures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fspor.2025.1644082","type":"journal-article","created":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T06:21:36Z","timestamp":1763446896000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Wearables for health monitoring: body composition estimates of commercial smartwatch and clinical bioelectrical impedance device"],"prefix":"10.3389","volume":"7","author":[{"given":"Bryson","family":"Carrier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda C.","family":"Melvin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob R.","family":"Outwin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marni G.","family":"Wasserman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam P.","family":"Audet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katherine C.","family":"Soldes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth M.","family":"Kozloff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam S.","family":"Lepley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,11,18]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1136\/bjsports-2023-106812","article-title":"Best practice recommendations for body composition considerations in sport to reduce health and performance risks: a critical review, original survey and expert opinion by a subgroup of the IOC consensus on relative energy deficiency in sport (REDs)","volume":"57","author":"Mathisen","year":"2023","journal-title":"Br J Sports Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.semcancer.2023.03.008","article-title":"Excess body weight: novel insights into its roles in obesity comorbidities","volume":"92","author":"Zhang","year":"2023","journal-title":"Semin Cancer Biol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"11070","DOI":"10.3390\/ijerph182111070","article-title":"The weight problem: overview of the most common concepts for body mass and fat distribution and critical consideration of their usefulness for risk assessment and practice","volume":"18","author":"Keszty\u00fcs","year":"2021","journal-title":"Int J Environ Res Public Health"},{"key":"B4","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s40519-017-0467-9","article-title":"Obesity phenotypes: depot-differences in adipose tissue and their clinical implications","volume":"23","author":"Guglielmi","year":"2018","journal-title":"Eat Weight Dis"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1161\/CIRCULATIONAHA.117.029617","article-title":"Cardiovascular and metabolic heterogeneity of obesity: clinical challenges and implications for management","volume":"137","author":"Neeland","year":"2018","journal-title":"Circulation"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12970-017-0174-y","article-title":"International society of sports nutrition position stand: diets and body composition","volume":"14","author":"Aragon","year":"2017","journal-title":"J Int Soc Sports Nutr"},{"key":"B7","doi-asserted-by":"publisher","first-page":"9464","DOI":"10.3390\/ijerph17249464","article-title":"Body composition in international sprint swimmers: are there any relations with performance?","volume":"17","author":"Dopsaj","year":"2020","journal-title":"Int J Environ Res Public Health"},{"key":"B8","doi-asserted-by":"publisher","first-page":"823","DOI":"10.3390\/biology11060823","article-title":"Assessment of body composition and physical performance of young soccer players: differences according to the competitive level","volume":"11","author":"Toselli","year":"2022","journal-title":"Biology (Basel)"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13102-021-00376-z","article-title":"The effect of body composition on strength and power in male and female students","volume":"13","author":"Ben Mansour","year":"2021","journal-title":"BMC Sports Sci Med Rehabil"},{"key":"B10","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1080\/17461391.2019.1612950","article-title":"Longitudinal associations between changes in body composition and changes in sprint performance in elite female sprinters","volume":"20","author":"Abe","year":"2020","journal-title":"Eur J Sport Sci"},{"key":"B11","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1016\/j.clnu.2022.07.032","article-title":"Accuracy of bioimpedance equations for measuring body composition in a cohort of 2134 patients with obesity","volume":"41","author":"Co\u00ebffier","year":"2022","journal-title":"Clin Nutr"},{"key":"B12","doi-asserted-by":"publisher","first-page":"648","DOI":"10.4103\/ijmr.IJMR_1777_18","article-title":"Body composition techniques","volume":"148","author":"Kuriyan","year":"2018","journal-title":"Indian J Med Res"},{"key":"B13","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.3390\/nu13082493","article-title":"The utility of body composition assessment in nutrition and clinical practice: an overview of current methodology","volume":"13","author":"Holmes","year":"2021","journal-title":"Nutrients"},{"key":"B14","volume-title":"ACSM\u2019s Guidelines for Exercise Testing and Prescription","year":"2013"},{"key":"B15","doi-asserted-by":"publisher","first-page":"112601","DOI":"10.1016\/j.nut.2024.112601","article-title":"The evolution of bioimpedance analysis: from traditional methods to wearable technology","volume":"129","author":"Mehra","year":"2024","journal-title":"Nutrition"},{"key":"B16","doi-asserted-by":"publisher","first-page":"10895","DOI":"10.3390\/s140610895","article-title":"The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases","volume":"14","author":"Khalil","year":"2014","journal-title":"Sensors"},{"key":"B17","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","article-title":"Research electronic data capture (REDCap)\u2014a metadata-driven methodology and workflow process for providing translational research informatics support","volume":"42","author":"Harris","year":"2009","journal-title":"J Biomed Inform"},{"key":"B18","year":""},{"key":"B19","doi-asserted-by":"publisher","first-page":"1767","DOI":"10.1249\/MSS.0000000000001966","article-title":"Standardizing analytic methods and reporting in activity monitor validation studies","volume":"51","author":"Welk","year":"2019","journal-title":"Med Sci Sports Exerc"},{"key":"B20","doi-asserted-by":"publisher","first-page":"70","DOI":"10.3390\/technologies8040070","article-title":"Validity and reliability of physiological data in applied settings measured by wearable technology: a rapid systematic review","volume":"8","author":"Carrier","year":"2020","journal-title":"Technologies"},{"key":"B21","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1249\/MSS.0000000000001481","article-title":"A primer on the use of equivalence testing for evaluating measurement agreement","volume":"50","author":"Dixon","year":"2018","journal-title":"Med Sci Sports Exerc"},{"key":"B22","doi-asserted-by":"publisher","first-page":"e37908","DOI":"10.1371\/journal.pone.0037908","article-title":"Statistical methods used to test for agreement of medical instruments measuring continuous variables in method comparison studies: a systematic review","volume":"7","author":"Zaki","year":"2012","journal-title":"PLoS One"},{"key":"B23","volume-title":"Statistical Concepts-a Second Course","author":"Hahs-Vaughn","year":"2020"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.70252\/PMWE7524","article-title":"Assessing the validity of several heart rate monitors in wearable technology while mountain biking","volume":"16","author":"Carrier","year":"2023","journal-title":"Int J Exerc Sci"},{"key":"B25","doi-asserted-by":"publisher","first-page":"S14","DOI":"10.1038\/ejcn.2012.160","article-title":"What makes a BIA equation unique? Validity of eight-electrode multifrequency BIA to estimate body composition in a healthy adult population","volume":"67","author":"Bosy-Westphal","year":"2013","journal-title":"Eur J Clin Nutr"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.1093\/ajcn\/nqac200","article-title":"Next-generation smart watches to estimate whole-body composition using bioimpedance analysis: accuracy and precision in a diverse, multiethnic sample","volume":"116","author":"Bennett","year":"2022","journal-title":"Am J Clin Nutr"},{"key":"B27","first-page":"44","article-title":"Validity and reliability of the wearable bioelectrical impedance measuring device","volume":"10","author":"Manc\u0131","year":"2018","journal-title":"Spor ve Performans Ara\u015ft\u0131rmalar\u0131 Dergisi"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1475-2891-7-26","article-title":"Is bioelectrical impedance accurate for use in large epidemiological studies?","volume":"7","author":"Dehghan","year":"2008","journal-title":"Nutr J"},{"key":"B29","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1016\/j.jocd.2018.10.008","article-title":"Reliability and agreement of various InBody body composition analyzers as compared to dual-energy x-ray absorptiometry in healthy men and women","volume":"23","author":"McLester","year":"2020","journal-title":"J Clin Densitom"},{"key":"B30","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.1007\/s40279-022-01665-4","article-title":"Recommendations for determining the validity of consumer wearables and smartphones for the estimation of energy expenditure: expert statement and checklist of the INTERLIVE network","volume":"52","author":"Argent","year":"2022","journal-title":"Sports Med"},{"key":"B31","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1038\/s41746-020-0297-4","article-title":"Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research","volume":"3","author":"Nelson","year":"2020","journal-title":"npj Digit. Med"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1644082\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T06:21:37Z","timestamp":1763446897000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1644082\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,18]]},"references-count":31,"alternative-id":["10.3389\/fspor.2025.1644082"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2025.1644082","relation":{},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,18]]},"article-number":"1644082"}}