{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T23:14:33Z","timestamp":1794870873430,"version":"4.9.1"},"reference-count":31,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T00:00:00Z","timestamp":1768176000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Body tracking systems are utilized in various areas such as health and sports. In these areas, it is crucial to identify the most accurate and appropriate system for the intended design of the study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This study evaluates the reliability of markerless motion capture systems compared to a marker-based system (OptiTrack) as the gold standard. The systems assessed include StereoLabs ZED 2i, MediaPipe (2D and 3D), and YOLOv8 Pose (8n and 8x-p6). Simple upper and lower limb movements were analyzed under controlled conditions in a single participant. Intraclass Correlation Coefficient (ICC) values and Bland-Altman analysis were mainly used to evaluate agreement between systems, with some other techniques explored to provide additional perspective.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The results indicate that StereoLabs ZED 2i achieved the highest reliability among markerless systems (ICC: 0.92 for multi camera, 0.88 for single stereo camera), while MediaPipe 2D showed competitive performance (ICC: 0.85).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>In providing comprehensive evaluations and uncovering performance differences that have been largely overlooked in the literature, our work not only questions existing paradigms but also lays a foundation for future research aimed at developing precise and scalable motion-tracking technologies. These findings contribute to understanding the applicability of markerless technologies in biomechanics.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fspor.2025.1712332","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T08:20:38Z","timestamp":1768206038000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":11,"title":["Reliability assessment of markerless technologies in biomechanical motion analysis: a performance comparison"],"prefix":"10.3389","volume":"7","author":[{"given":"Ibrahim Cem","family":"Balci","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irem","family":"Sayin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serkan","family":"Salturk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rana","family":"Gursoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Umut","family":"Ozsoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Husnu Caglar","family":"Dogru","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gokhan","family":"Akca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Eraslan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Onurcan","family":"Sahin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali Anil","family":"Demircali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huseyin","family":"Uvet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,1,12]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.gaitpost.2018.11.029","article-title":"Three-dimensional cameras and skeleton pose tracking for physical function assessment: a review of uses, validity, current developments and kinect alternatives","volume":"68","author":"Clark","year":"2019","journal-title":"Gait Posture"},{"key":"B2","doi-asserted-by":"crossref","DOI":"10.1115\/DETC2013-12653","article-title":"Comparison of marker-based and marker-less systems for low-cost human motion capture","author":"Puthenveetil","year":""},{"key":"B3","doi-asserted-by":"publisher","first-page":"e12995","DOI":"10.7717\/PEERJ.12995","article-title":"Applications and limitations of current markerless motion capture methods for clinical gait biomechanics","volume":"10","author":"Wade","year":"2022","journal-title":"PeerJ"},{"key":"B4","doi-asserted-by":"publisher","first-page":"22880","DOI":"10.1038\/S41598-023-49360-2","article-title":"Comparison of markerless and marker-based motion capture systems using 95 framework","volume":"13","author":"Das","year":"2023","journal-title":"Sci Rep"},{"key":"B5","doi-asserted-by":"publisher","first-page":"e0271349","DOI":"10.1371\/JOURNAL.PONE.0271349","article-title":"Accuracy measurement of different marker based motion analysis systems for biomechanical applications: a round robin study","volume":"17","author":"Schroeder","year":"2022","journal-title":"PLoS One"},{"key":"B6","doi-asserted-by":"publisher","first-page":"S90","DOI":"10.1016\/J.INJURY.2019.11.011","article-title":"Gait analysis \u2013 available platforms for outcome assessment","volume":"51","author":"Kl\u00f6pfer-Kr\u00e4mer","year":"2020","journal-title":"Injury"},{"key":"B7","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1080\/17461391.2018.1463397","article-title":"Accuracy of human motion capture systems for sport applications; state-of-the-art review","volume":"18","author":"van der Kruk","year":"2018","journal-title":"Eur J Sport Sci"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/6628320","article-title":"Inertial-based human motion capture: a technical summary of current processing methodologies for spatiotemporal and kinematic measures","volume":"2021","author":"Hindle","year":"2021","journal-title":"Appl Bionics Biomech"},{"key":"B9","article-title":"Mediapipe: a framework for building perception pipelines","author":"Lugaresi","year":""},{"key":"B10","first-page":"38571","article-title":"Vitpose: simple vision transformer baselines for human pose estimation","volume":"35","author":"Xu","year":"2022","journal-title":"Adv Neural Inf Process Syst"},{"key":"B11","doi-asserted-by":"publisher","first-page":"103275","DOI":"10.1016\/j.cviu.2021.103275","article-title":"A review of 3D human pose estimation algorithms for markerless motion capture","volume":"212","author":"Desmarais","year":"2021","journal-title":"Comput Vis Image Underst"},{"key":"B12","doi-asserted-by":"publisher","first-page":"111751","DOI":"10.1016\/j.jbiomech.2023.111751","article-title":"Markerless motion capture estimates of lower extremity kinematics and kinetics are comparable to marker-based across 8 movements","volume":"157","author":"Song","year":"2023","journal-title":"J Biomech"},{"key":"B13","article-title":"Data from: Stereolabs documentation (2025)","year":""},{"key":"B14","doi-asserted-by":"publisher","first-page":"3371","DOI":"10.3390\/s24113371","article-title":"Development of a low-cost markerless optical motion capture system for gait analysis and anthropometric parameter quantification","volume":"24","author":"Espitia-Mora","year":"2024","journal-title":"Sensors"},{"key":"B15","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s40798-018-0139-y","article-title":"A review of the evolution of vision-based motion analysis and the integration of advanced computer vision methods towards developing a markerless system","volume":"4","author":"Colyer","year":"2018","journal-title":"Sports Med Open"},{"key":"B16","doi-asserted-by":"publisher","first-page":"112049","DOI":"10.1016\/j.jbiomech.2024.112049","article-title":"Inter-trial variability is higher in 3D markerless compared to marker-based motion capture: implications for data post-processing and analysis","volume":"166","author":"Horsak","year":"2024","journal-title":"J Biomech"},{"key":"B17","doi-asserted-by":"publisher","first-page":"110665","DOI":"10.1016\/j.jbiomech.2021.110665","article-title":"Concurrent assessment of gait kinematics using marker-based and markerless motion capture","volume":"127","author":"Kanko","year":"2021","journal-title":"J Biomech"},{"key":"B18","doi-asserted-by":"publisher","first-page":"111793","DOI":"10.1016\/j.jbiomech.2023.111793","article-title":"A comparison of three-dimensional kinematics between markerless and marker-based motion capture in overground gait","volume":"159","author":"Ripic","year":"2023","journal-title":"J Biomech"},{"key":"B19","doi-asserted-by":"publisher","first-page":"e0293917","DOI":"10.1371\/journal.pone.0293917","article-title":"Examination of 2d frontal and sagittal markerless motion capture: implications for markerless applications","volume":"18","author":"Wade","year":"2023","journal-title":"PLoS One"},{"key":"B20","doi-asserted-by":"publisher","first-page":"100128","DOI":"10.1016\/j.bea.2024.100128","article-title":"Validation of upper extremity kinematics using markerless motion capture","volume":"7","author":"Hansen","year":"2024","journal-title":"Biomed Eng Adv"},{"key":"B21","doi-asserted-by":"publisher","first-page":"2049","DOI":"10.1016\/j.jse.2022.04.007","article-title":"Reliability and agreement of azure kinect and kinect v2 depth sensors in the shoulder joint range of motion estimation","volume":"31","author":"\u00d6zsoy","year":"2022","journal-title":"J Shoulder Elb Surg"},{"key":"B22","doi-asserted-by":"publisher","first-page":"112018","DOI":"10.1016\/j.jbiomech.2024.112018","article-title":"Agreement between a markerless and a marker-based motion capture systems for balance related quantities","volume":"165","author":"Chaumeil","year":"2024","journal-title":"J Biomech"},{"key":"B23","doi-asserted-by":"publisher","first-page":"114857","DOI":"10.1016\/j.measurement.2024.114857","article-title":"Improved markerless gait kinematics measurement using a biomechanically-aware algorithm with subject-specific geometric modeling","volume":"234","author":"Hatamzadeh","year":"2024","journal-title":"Measurement"},{"key":"B24","doi-asserted-by":"publisher","first-page":"6186","DOI":"10.1109\/JBHI.2024.3424869","article-title":"Anatomical-marker-driven 3D markerless human motion capture","volume":"29","author":"Jatesiktat","year":"2024","journal-title":"IEEE J Biomed Health Inform"},{"key":"B25","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/J.CLINBIOMECH.2011.01.015","article-title":"Multi-segment trunk kinematics during locomotion and elementary exercises","volume":"26","author":"Leardini","year":"2011","journal-title":"Clin Biomech"},{"key":"B26","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/J.GAITPOST.2006.12.018","article-title":"A new anatomically based protocol for gait analysis in children","volume":"26","author":"Leardini","year":"2007","journal-title":"Gait Posture"},{"key":"B27","article-title":"Optitrack documentation (2025)","year":""},{"key":"B28","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/J.JCM.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.21105\/JOSS.01026","article-title":"Pingouin: statistics in python","volume":"3","author":"Vallat","year":"2018","journal-title":"J Open Source Softw"},{"key":"B30","first-page":"231","article-title":"Quantifying test-retest reliability using the intraclass correlation coefficient and the sem","volume":"19","author":"Weir","year":"2005","journal-title":"J Strength Cond Res"},{"key":"B31","doi-asserted-by":"publisher","first-page":"110519","DOI":"10.1016\/j.ijmecsci.2025.110519","article-title":"Data-driven deep learning for predicting ligament fatigue failure risk mechanisms","volume":"301","author":"Xu","year":"2025","journal-title":"Int J Mech Sci"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1712332\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T08:20:40Z","timestamp":1768206040000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2025.1712332\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,12]]},"references-count":31,"alternative-id":["10.3389\/fspor.2025.1712332"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2025.1712332","relation":{"has-part":[{"id-type":"doi","id":"https:\/\/doi.org\/10.3389\/fspor.2025.1712332.s001","asserted-by":"subject"}]},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,12]]},"article-number":"1712332"}}