{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T12:09:08Z","timestamp":1781093348878,"version":"3.54.1"},"reference-count":35,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T00:00:00Z","timestamp":1781049600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:p>Running-specific prostheses (RSPs) enable individuals with lower-limb amputation to compete in Paralympic running disciplines. In a high-level sports context, optimal RSP tuning based on biomechanical parameters is essential to enhance running performance. Although on-track assessment is considered the gold standard, its high financial and logistical demands make treadmill-based setups valuable alternatives. Therefore, this single-case study aimed to present a method for assessing steady-state running (SSR) and resisted acceleration running (RAR) in an amputee athlete, comparing different RSP alignments. The experimental setup combined a commercial treadmill mounted over four dynamometric platforms with an eight-camera motion capture system, enabling the kinetic, kinematic, and spatiotemporal assessment of different RSP configurations. Differences in biomechanical parameters were observed between RSP configurations during both SSR and RAR, including variations in GRFs and corresponding impulses, as well as hip, knee, and ankle kinematics. However, the sensitivity of the proposed method in detecting biomechanical differences should be interpreted with caution, as it is based on a single Paralympic athlete. In conclusion, these findings suggest that the treadmill-based protocol may serve as a functional and controlled screening tool for preliminary performance-oriented RSP tuning, enabling the identification of promising configurations prior to definitive assessments on an instrumented athletics track.<\/jats:p>","DOI":"10.3389\/fspor.2026.1817303","type":"journal-article","created":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T11:46:16Z","timestamp":1781091976000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Treadmill-based assessment of running-specific prostheses in steady and accelerated running: a case study with a Paralympic medalist"],"prefix":"10.3389","volume":"8","author":[{"given":"Samira G.","family":"Breban","sequence":"first","affiliation":[{"name":"Department of Industrial Engineering, University of Padova","place":["Padova, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Marcolin","sequence":"additional","affiliation":[{"name":"Department of Biomedical Sciences, University of Padova","place":["Padova, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Di Marco","sequence":"additional","affiliation":[{"name":"Centro Protesi, INAIL","place":["Bologna, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea G.","family":"Cutti","sequence":"additional","affiliation":[{"name":"Centro Protesi, INAIL","place":["Bologna, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gian Luca","family":"Migliore","sequence":"additional","affiliation":[{"name":"Centro Protesi, INAIL","place":["Bologna, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Petrone","sequence":"additional","affiliation":[{"name":"Department of Industrial Engineering, University of Padova","place":["Padova, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,6,10]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s40798-019-0221-0","article-title":"The training and development of elite sprint performance: an integration of scientific and best practice literature","volume":"5","author":"Haugen","year":"2019","journal-title":"Sports Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1515\/hukin-2015-0014","article-title":"Selected determinants of acceleration in the 100 m sprint","volume":"45","author":"Ma\u0107ka\u0142a","year":"2015","journal-title":"J Hum Kinet"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1784","DOI":"10.1111\/sms.13093","article-title":"Kinetic demands of sprinting shift across the acceleration phase: novel analysis of entire force waveforms","volume":"28","author":"Colyer","year":"2018","journal-title":"Scand J Med Sci Sports"},{"key":"B4","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1260\/1747-9541.6.3.479","article-title":"The science of speed: determinants of performance in the 100 m sprint","volume":"6","author":"Majumdar","year":"2011","journal-title":"Int J Sports Sci Coach"},{"key":"B5","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jbiomech.2016.11.058","article-title":"Regulation of step frequency in transtibial amputee endurance athletes using a running-specific prosthesis","volume":"51","author":"Oudenhoven","year":"2017","journal-title":"J Biomech"},{"key":"B6","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1249\/MSS.0000000000002203","article-title":"A limb-specific strategy across a range of running speeds in transfemoral amputees","volume":"52","author":"Sakata","year":"2020","journal-title":"Med Sci Sports Exercise"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1038\/s41598-019-56479-8","article-title":"Prosthetic model, but not stiffness or height, affects maximum running velocity in athletes with unilateral transtibial amputations","volume":"10","author":"Taboga","year":"2020","journal-title":"Sci Rep"},{"key":"B8","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1152\/japplphysiol.00587.2016","article-title":"Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations","volume":"122","author":"Beck","year":"2017","journal-title":"J Appl Physiol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"211691","DOI":"10.1098\/rsos.211691","article-title":"Running-specific prosthesis model, stiffness and height affect biomechanics and asymmetry of athletes with unilateral leg amputations across speeds","volume":"9","author":"Tacca","year":"2022","journal-title":"R Soc Open Sci"},{"key":"B10","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1177\/0309364620946910","article-title":"Innovative alignment of sprinting prostheses for persons with transfemoral amputation: exploratory study on a gold medal Paralympic athlete","volume":"45","author":"Migliore","year":"2021","journal-title":"Prosthet Orthot Int"},{"key":"B11","doi-asserted-by":"publisher","first-page":"89","DOI":"10.3390\/sports9070089","article-title":"How can biomechanics improve physical preparation and performance in Paralympic athletes? A narrative review","volume":"9","author":"Fletcher","year":"2021","journal-title":"Sports"},{"key":"B12","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1123\/jab.2016-0356","article-title":"Association of sprint performance with ground reaction forces during acceleration and maximal speed phases in a single sprint","volume":"34","author":"Nagahara","year":"2018","journal-title":"J Appl Biomech"},{"key":"B13","first-page":"15","article-title":"Braking and propulsive impulses across a range of running speeds in unilateral transfemoral amputees","volume-title":"ISBS Proc Arch","author":"Sakata","year":"2019"},{"key":"B14","doi-asserted-by":"publisher","first-page":"110323","DOI":"10.1016\/j.jbiomech.2021.110323","article-title":"Low-pass filter cutoff frequency affects sacral-mounted inertial measurement unit estimations of peak vertical ground reaction force and contact time during treadmill running","volume":"119","author":"Day","year":"2021","journal-title":"J Biomech"},{"key":"B15","doi-asserted-by":"publisher","first-page":"e12752","DOI":"10.7717\/peerj.12752","article-title":"Predicting continuous ground reaction forces from accelerometers during uphill and downhill running: a recurrent neural network solution","volume":"10","author":"Alcantara","year":"2022","journal-title":"PeerJ"},{"key":"B16","doi-asserted-by":"publisher","first-page":"e11199","DOI":"10.7717\/peerj.11199","article-title":"Sacral acceleration can predict whole-body kinetics and stride kinematics across running speeds","volume":"9","author":"Alcantara","year":"2021","journal-title":"PeerJ"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1055\/s-0042-107248","article-title":"Comparison of 3 methods for computing loading rate during running","volume":"37","author":"Ueda","year":"2016","journal-title":"Int J Sports Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1007\/s00421-010-1804-0","article-title":"Sprint running performance: comparison between treadmill and field conditions","volume":"111","author":"Morin","year":"2011","journal-title":"Eur J Appl Physiol"},{"key":"B19","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1007\/s40279-019-01237-z","article-title":"Is motorized treadmill running biomechanically comparable to overground running? A systematic review and meta-analysis of cross-over studies","volume":"50","author":"Van Hooren","year":"2020","journal-title":"Sports Med"},{"key":"B20","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/PXR.0000000000000175","article-title":"Biomechanical determinants of top running speeds in para-athletes with unilateral transfemoral amputation","volume":"47","author":"Hobara","year":"2022","journal-title":"Prosthet Orthot Int"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1255","DOI":"10.1007\/s40279-016-0653-3","article-title":"Methods of power-force-velocity profiling during sprint running: a narrative review","volume":"47","author":"Cross","year":"2017","journal-title":"Sports Med"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1016\/j.jbiomech.2010.03.012","article-title":"Direct measurement of power during one single sprint on treadmill","volume":"43","author":"Morin","year":"2010","journal-title":"J Biomech"},{"key":"B23","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1519\/JSC.0b013e3181964a7a","article-title":"The effects of treadmill sprint training and resistance training on maximal running velocity and power","volume":"23","author":"Ross","year":"2009","journal-title":"J Strength Cond Res"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1655295","DOI":"10.3389\/fbioe.2025.1655295","article-title":"A motion capture protocol for the kinematic analysis of transfemoral and transtibial sprinters","volume":"13","author":"Di Marco","year":"2025","journal-title":"Front Bioeng Biotechnol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1109\/10.649988","article-title":"Surface-marker cluster design criteria for 3-D bone movement reconstruction","volume":"44","author":"Cappozzo","year":"1997","journal-title":"IEEE Trans Biomed Eng"},{"key":"B26","first-page":"236","article-title":"Running mechanics in unilateral transfemoral amputees across a range of speeds","volume-title":"ISBS Proc Arch","author":"Sakata","year":"2018"},{"key":"B27","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1016\/j.gaitpost.2013.08.010","article-title":"Amputee locomotion: lower extremity loading using running-specific prostheses","volume":"39","author":"Hobara","year":"2014","journal-title":"Gait Posture"},{"key":"B28","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1123\/jab.2017-0008","article-title":"Ground reaction forces during sprinting in unilateral transfemoral amputees","volume":"33","author":"Makimoto","year":"2017","journal-title":"J Appl Biomech"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1991","DOI":"10.1152\/jappl.2000.89.5.1991","article-title":"Faster top running speeds are achieved with greater ground forces not more rapid leg movements","volume":"89","author":"Weyand","year":"2000","journal-title":"In J Appl Physiol"},{"key":"B30","doi-asserted-by":"publisher","first-page":"3149","DOI":"10.1016\/j.jbiomech.2015.07.009","article-title":"Acceleration capability in elite sprinters and ground impulse: push more, brake less?","volume":"48","author":"Morin","year":"2015","journal-title":"J Biomech"},{"key":"B31","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1016\/S0003-9993(99)90189-2","article-title":"Sprint kinematics of athletes with lower-limb amputations","volume":"80","author":"Buckley","year":"1999","journal-title":"Arch Phys Med Rehabil"},{"key":"B32","first-page":"655","article-title":"Return to running following a knee disarticulation amputation: a case report","volume":"12","author":"Diebal-Lee","year":"2017","journal-title":"Int J Sports Phys Ther"},{"key":"B33","doi-asserted-by":"publisher","first-page":"15","DOI":"10.2478\/hukin-2021-0008","article-title":"of the swing-pull technique","volume":"77","author":"Mattes","year":"2021","journal-title":"J Hum Kinet"},{"key":"B34","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1519\/00126548-200608000-00006","article-title":"Resisted sprint training for the acceleration phase of sprinting","volume":"28","author":"Cronin","year":"2006","journal-title":"Strength Cond J"},{"key":"B35","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1098\/rsbl.2009.0729","article-title":"Running-specific prostheses limit ground-force during sprinting","volume":"6","author":"Grabowski","year":"2010","journal-title":"Biol Lett"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2026.1817303\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T11:46:17Z","timestamp":1781091977000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2026.1817303\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,10]]},"references-count":35,"alternative-id":["10.3389\/fspor.2026.1817303"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2026.1817303","relation":{},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,10]]},"article-number":"1817303"}}