{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T06:11:00Z","timestamp":1783923060424,"version":"3.55.0"},"reference-count":25,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T00:00:00Z","timestamp":1783900800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Sports Act. Living"],"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>This study examined how camera geometry influences the agreement of two-camera markerless joint-angle estimates with an eight-camera markerless reference system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Twenty-three female soccer athletes completed pre-season Y-balance, L-hop, countermovement jump, broad jump, and bodyweight squat tasks. Movements were recorded using an eight-camera Theia3D markerless system as the reference. All 28 two-camera combinations were processed using a custom Pose2Sim-based pipeline to estimate lower-limb joint angles. Camera geometry was quantified from calibration data, including camera height, distance to origin, azimuth, field of view, and horizontal angular separation. Agreement with the reference system and consistency among two-camera configurations were assessed using root mean square error (RMSE), mean absolute error (MAE), bias, limits of agreement, and coefficient of multiple correlation (CMC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Agreement varied by camera geometry, anatomical plane, and task. Front and Back configurations, with moderate horizontal angular separation values of 68.59\u2009\u00b1\u200917.68\u00b0 and 80.95\u2009\u00b1\u200922.35\u00b0, generally showed more favorable agreement, particularly for sagittal-plane hip and knee kinematics (RMSE\u2009&amp;lt;\u20098\u00b0, CMC\u2009\u2248\u20091.00). Same Quadrant configurations had the smallest angular separation (28.24\u2009\u00b1\u20093.81\u00b0) and poorer agreement, especially for frontal- and transverse-plane angles (RMSE\u2009&amp;gt;\u200910\u00b0, CMC\u2009&amp;lt;\u20090.60). Diagonal configurations had the largest angular separation (160.56\u2009\u00b1\u200913.40\u00b0) but did not consistently improve agreement. Y-balance and L-hop showed reduced agreement and higher dropout due to self-occlusion and participants moving outside the field of view.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Camera geometry influenced two-camera markerless motion capture agreement. Front and Back configurations with moderate angular separation were most suitable for sagittal-dominant bilateral tasks, whereas Same Quadrant configurations should be avoided. For Y-balance and L-hop, camera placement should prioritize foot\/ankle visibility and full movement-path coverage rather than angular separation alone.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fspor.2026.1850018","type":"journal-article","created":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T05:34:57Z","timestamp":1783920897000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Influence of camera geometry on 3D joint angle estimation in markerless motion capture"],"prefix":"10.3389","volume":"8","author":[{"given":"Xiong","family":"Zhao","sequence":"first","affiliation":[{"name":"School of Human Kinetics, Faculty of Health Sciences, University of Ottawa","place":["Ottawa, Ontario, Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Google LLC","place":["Mountain View, California, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan B.","family":"Graham","sequence":"additional","affiliation":[{"name":"School of Human Kinetics, Faculty of Health Sciences, University of Ottawa","place":["Ottawa, Ontario, Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,13]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1017\/CBO9780511811685.014","article-title":"Epipolar geometry and the fundamental matrix","author":"Hartley","year":"2004","journal-title":"Multiple View Geometry in Computer Vision"},{"key":"B2","doi-asserted-by":"publisher","first-page":"109730","DOI":"10.1016\/j.celrep.2021.109730","article-title":"Anipose: a toolkit for robust markerless 3D pose estimation","volume":"36","author":"Karashchuk","year":"2021","journal-title":"Cell Rep"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-021-00212-x","article-title":"The accuracy of several pose estimation methods for 3D joint centre localisation","volume":"11","author":"Needham","year":"2021","journal-title":"Sci Rep"},{"key":"B4","doi-asserted-by":"publisher","first-page":"110665","DOI":"10.1016\/j.jbiomech.2021.110665","article-title":"Concurrent assessment of gait kinematics using marker-based and markerless motion capture","volume":"127","author":"Kanko","year":"2021","journal-title":"J Biomech"},{"key":"B5","doi-asserted-by":"publisher","first-page":"e1011462","DOI":"10.1371\/journal.pcbi.1011462","article-title":"Opencap: human movement dynamics from smartphone videos","volume":"19","author":"Uhlrich","year":"2023","journal-title":"PLoS Comput Biol"},{"key":"B6","doi-asserted-by":"publisher","first-page":"111801","DOI":"10.1016\/j.jbiomech.2023.111801","article-title":"Concurrent validity of smartphone-based markerless motion capturing to quantify lower-limb joint kinematics in healthy and pathological gait","volume":"159","author":"Horsak","year":"2023","journal-title":"J Biomech"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1847","DOI":"10.1080\/02640414.2024.2415233","article-title":"Validity and reliability of trunk and lower-limb kinematics during squatting, hopping, jumping and side-stepping using OpenCap markerless motion capture application","volume":"42","author":"Lima","year":"2024","journal-title":"J Sports Sci"},{"key":"B8","doi-asserted-by":"publisher","first-page":"112200","DOI":"10.1016\/j.jbiomech.2024.112200","article-title":"Validation of OpenCap: a low-cost markerless motion capture system for lower-extremity kinematics during return-to-sport tasks","volume":"171","author":"Turner","year":"2024","journal-title":"J Biomech"},{"key":"B9","doi-asserted-by":"publisher","first-page":"112602","DOI":"10.1016\/j.jbiomech.2025.112602","article-title":"Validation of OpenCap on lower extremity kinematics during functional tasks","volume":"183","author":"Svetek","year":"2025","journal-title":"J Biomech"},{"key":"B10","doi-asserted-by":"publisher","first-page":"108101","DOI":"10.1016\/j.compbiomed.2024.108101","article-title":"On the reliability of single-camera markerless systems for overground gait monitoring","volume":"171","author":"Boldo","year":"2024","journal-title":"Comput Biol Med"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1298003","DOI":"10.3389\/fspor.2023.1298003","article-title":"Feasibility of OpenPose markerless motion analysis in a real athletics competition","volume":"5","author":"Cronin","year":"2023","journal-title":"Front Sports Act Living"},{"key":"B12","doi-asserted-by":"publisher","first-page":"6849","DOI":"10.21105\/joss.06849","article-title":"Sports2D: compute 2D human pose and angles from a video or a webcam","volume":"9","author":"Pagnon","year":"2024","journal-title":"Journal of Open Source Software"},{"key":"B13","author":"Jiang","year":"2023"},{"key":"B14","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1109\/TBME.2025.3530848","article-title":"Marker data enhancement for markerless motion capture","volume":"72","author":"Falisse","year":"2025","journal-title":"IEEE Trans Biomed Eng"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","article-title":"Opensim: open-source software to create and analyze dynamic simulations of movement","volume":"54","author":"Delp","year":"2007","journal-title":"IEEE Trans Biomed Eng"},{"key":"B16","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.gaitpost.2008.09.003","article-title":"The reliability of three-dimensional kinematic gait measurements: a systematic review","volume":"29","author":"McGinley","year":"2009","journal-title":"Gait Posture"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation","volume":"126","author":"Schober","year":"2018","journal-title":"Anesth Analg"},{"key":"B18","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.gaitpost.2023.05.029","article-title":"Comparison of kinematics between theia markerless and conventional marker-based gait analysis in clinical patients","volume":"104","author":"Wren","year":"2023","journal-title":"Gait Posture"},{"key":"B19","doi-asserted-by":"publisher","first-page":"110422","DOI":"10.1016\/j.jbiomech.2021.110422","article-title":"Inter-session repeatability of markerless motion capture gait kinematics","volume":"121","author":"Kanko","year":"2021","journal-title":"J Biomech"},{"key":"B20","doi-asserted-by":"publisher","first-page":"111751","DOI":"10.1016\/j.jbiomech.2023.111751","article-title":"Markerless motion capture estimates of lower extremity kinematics and kinetics are comparable to marker-based across 8 movements","volume":"157","author":"Song","year":"2023","journal-title":"J Biomech"},{"key":"B21","doi-asserted-by":"publisher","first-page":"3412","DOI":"10.1016\/j.jbiomech.2007.05.019","article-title":"Foot kinematics during walking measured using bone and surface mounted markers","volume":"40","author":"Nester","year":"2007","journal-title":"J Biomech"},{"key":"B22","doi-asserted-by":"publisher","first-page":"113065","DOI":"10.1016\/j.jbiomech.2025.113065","article-title":"Assessing agreement and usability of kinematic measures between markerless and marker-based motion capture systems during jumping activities","volume":"194","author":"Kwak","year":"2026","journal-title":"J Biomech"},{"key":"B23","author":"Darapaneni","year":"2022"},{"key":"B24","doi-asserted-by":"publisher","first-page":"281","DOI":"10.3390\/biomechanics2020022","article-title":"Biomechanical risk factors of injury-related single-leg movements in male elite youth soccer players","volume":"2","author":"Kolodziej","year":"2022","journal-title":"Biomechanics"},{"key":"B25","doi-asserted-by":"publisher","first-page":"3091","DOI":"10.3390\/s24103091","article-title":"A step forward understanding directional limitations in markerless smartphone-based gait analysis: a pilot study","volume":"24","author":"Marti\u0161","year":"2024","journal-title":"Sensors"}],"container-title":["Frontiers in Sports and Active Living"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2026.1850018\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T05:34:58Z","timestamp":1783920898000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fspor.2026.1850018\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,13]]},"references-count":25,"alternative-id":["10.3389\/fspor.2026.1850018"],"URL":"https:\/\/doi.org\/10.3389\/fspor.2026.1850018","relation":{},"ISSN":["2624-9367"],"issn-type":[{"value":"2624-9367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,13]]},"article-number":"1850018"}}