{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T15:47:10Z","timestamp":1783180030745,"version":"3.54.6"},"reference-count":11,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2020,12,16]],"date-time":"2020-12-16T00:00:00Z","timestamp":1608076800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004772","name":"Natural Science Foundation of Ningxia Province","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004772","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004179","name":"Ningxia Medical University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004179","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:p><jats:bold>Objective:<\/jats:bold> To investigate whether tendon reconstruction during mitral valve repair can be effectively guided by transesophageal echocardiography (TEE), using the mid-esophageal bi-commissure view, bicaval view and the aortic valve\u2013mitral valve transition short-axis view.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> A total of 40 patients that underwent mitral valve repair with artificial tendineae were recruited. Before the operation, conventional transthoracic echocardiography was used to determine whether mitral valve repair would be possible. Following intraoperative anesthesia, two-dimensional and three-dimensional TEE reconstructions were used to assess the state of the valve and tendon and to make a repair plan.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> TEE accurately diagnosed single functional tendon rupture and predicted single artificial tendon implantation in 88% of cases (23\/26). TEE accurately diagnosed single functional tendon rupture and predicted the implantation of two artificial tendons in 100% of cases (4\/4). TEE accurately diagnosed two or more functional tendon ruptures and predicted the implantation of two artificial tendons in 100% of cases (5\/5). The length of the tendon cord predicted by TEE (2.45 \u00b1 0.15 mm) was not significantly different (<jats:italic>P<\/jats:italic> &amp;gt; 0.05) from the length of the cord that was actually implanted (2.31 \u00b1 0.11 mm). TEE also accurately predicted the size of the annuloplasty ring in 86% of cases (33\/38), with differences of 2 mm or less compared to the size of the ring that was actually implanted.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Both the mid-esophageal bi-commissure view, bicaval view and the short-axis view of the aortic valve\u2013mitral valve transition can reduce the difficulty of tendon reconstruction by helping to determine what length of tendon and what size of artificial annulus are required.<\/jats:p>","DOI":"10.3389\/fsurg.2020.599746","type":"journal-article","created":{"date-parts":[[2021,1,10]],"date-time":"2021-01-10T10:42:42Z","timestamp":1610275362000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["The Application of Transesophageal Echocardiography in Mitral Valve Repair With Tendon Reconstruction"],"prefix":"10.3389","volume":"7","author":[{"given":"Li","family":"Zhou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji-wei","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing-jing","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting-ting","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-sha","family":"Na","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2020,12,16]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"352","DOI":"10.3348\/kjr.2018.0350","article-title":"Utility of cardiac CT for preoperative evaluation of mitral regurgitation: morphological evaluation of mitral valve and prediction of valve replacement","volume":"20","author":"Suh","year":"2019","journal-title":"Korean J Radiol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"AA22","DOI":"10.4244\/EIJ-D-17-00505","article-title":"Mitral valve: repair\/clips\/cinching\/chordae","volume":"13","author":"Vahanian","year":"2017","journal-title":"EuroIntervention."},{"key":"B3","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1007\/s10396-019-00971-1","article-title":"Echocardiographic assessment of mitral regurgitation","volume":"47","author":"Kagiyama","year":"2020","journal-title":"J Med Ultrason (2001)."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1016\/j.athoracsur.2011.03.111","article-title":"Measured tube technique for ensuring the correct length of slippery artificial chordae in mitral valvuloplasty","volume":"92","author":"Matsui","year":"2011","journal-title":"Ann Thorac Surg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1016\/S0002-9149(84)80222-2","article-title":"Clinical applications of a new type of real-time two-dimensional Doppler flow imaging system","volume":"54","author":"Miyatake","year":"1984","journal-title":"Am J Cardiol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1093\/ejechocard\/jep173","article-title":"The routine use of live three-dimensional transesophageal echocardiography IM mitral valve surgery: clinical experience","volume":"11","author":"Wei","year":"2010","journal-title":"Eur J Echocardiogr."},{"key":"B7","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1007\/s12574-015-0255-3","article-title":"Impact of real-time three-dimensional transesophageal echocardiography on procedural success for mitral valve repair","volume":"13","author":"Mori","year":"2015","journal-title":"J Echocardiogr."},{"key":"B8","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1186\/1749-8090-8-137","article-title":"Real-time three-dimensional transesophageal echocardiography to predict artificial chordae length for mitral valve repair","volume":"8","author":"Huang","year":"2013","journal-title":"J Cardiothorac Surg."},{"key":"B9","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/0002-8703(94)90492-8","article-title":"Clinical application of three-dimensional transesophageal echocardiography","volume":"128","author":"Wang","year":"1994","journal-title":"Am Heart J."},{"key":"B10","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1097\/00000539-199910000-00010","article-title":"ASE\/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for certification in perioperative transesophageal echocardiography","volume":"89","author":"Shanewise","year":"1999","journal-title":"Anesth Analg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1007\/s10554-006-9181-9","article-title":"True mitral annulus diameter is underestimated by two-dimensional echocardiography as evidenced by real-time three-dimensional echocardiography and magnetic resonance imaging","volume":"23","author":"Anwar","year":"2007","journal-title":"Int J Cardiovasc Imaging."}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2020.599746\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,10]],"date-time":"2021-01-10T10:42:45Z","timestamp":1610275365000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2020.599746\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,16]]},"references-count":11,"alternative-id":["10.3389\/fsurg.2020.599746"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2020.599746","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,16]]},"article-number":"599746"}}