{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T16:34:36Z","timestamp":1753893276639,"version":"3.41.2"},"reference-count":22,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,12,19]],"date-time":"2022-12-19T00:00:00Z","timestamp":1671408000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Suture passer needle, as one of commonly used instrument in the arthroscopic rotator cuff repair, often breaks at the notch of the needle, which originally was designed to facilitate suture with thread. Our study aimed to evaluate the suture failure rate and stitch success rate between intact suture needle and broken needle and explore the mechanism of the needle breakage and achieving better future designs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and methods<\/jats:title><jats:p>From 2017 to 2021, consecutive 437 shoulders (11 cases were bilateral) underwent arthroscopic repair for full-thickness rotator cuff tear at the authors\u2019 institution. The breakage of needles was recorded. Finite elements analysis and mechanical test were utilized to compare stress distribution, puncture performance, and loaded puncture performance between the broken needle and the intact needle.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>We identified 19 consecutive patients for whom the needle tip of the TruePass\u2122 suture passer was broken in the 437 shoulder surgeries. Based on the finite element analysis of Abaqus, around the tip and the notch of the intact needle was a large stress concentration. The average puncture force required by intact needle tip and the broken tip is 61.78N and 78.23N respectively. While the intact tip with notch is easier to break than the broken tip.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The notch of the needle is a weak point in mechanics. The broken needle without the notch still has good tendon piercing and thread passing ability. The notch of needle may be not necessary, and the tip of the needle should be modified.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fsurg.2022.1065666","type":"journal-article","created":{"date-parts":[[2022,12,19]],"date-time":"2022-12-19T10:27:22Z","timestamp":1671445642000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Mechanical mechanism of suture passer needle break in rotator cuff repair"],"prefix":"10.3389","volume":"9","author":[{"given":"Chunxi","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zikai","family":"Hua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bingchen","family":"An","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,12,19]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/j.jse.2020.08.022","article-title":"Determining the rate of full-thickness progression in partial-thickness rotator cuff tears: a systematic review","volume":"30","author":"Tsuchiya","year":"2021","journal-title":"J Shoulder Elbow Surg"},{"key":"B2","doi-asserted-by":"publisher","first-page":"e193","DOI":"10.5435\/JAAOS-D-19-00463","article-title":"Management of rotator cuff injuries","volume":"28","author":"Weber","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/1749-799X-2-24","article-title":"The results of arthroscopic versus mini-open repair for rotator cuff tears at mid-term follow-up","volume":"2","author":"Pearsall","year":"2007","journal-title":"J Orthop Surg Res"},{"key":"B4","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.arthro.2017.07.028","article-title":"Five-year outcomes after arthroscopic repair of partial-thickness supraspinatus tears","volume":"34","author":"Vap","year":"2018","journal-title":"Arthroscopy"},{"key":"B5","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/j.arthro.2007.01.011","article-title":"Early outcome of arthroscopic rotator cuff repair: a matched comparison with mini-open rotator cuff repair","volume":"23","author":"Kang","year":"2007","journal-title":"Arthroscopy"},{"key":"B6","doi-asserted-by":"publisher","first-page":"180091","DOI":"10.1148\/ryai.2019180091","article-title":"Fully automated diagnosis of anterior cruciate ligament tears on knee MR images by using deep learning","volume":"1","author":"Liu","year":"2019","journal-title":"Radiol Artif Intell"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1016\/j.arthro.2012.02.031","article-title":"Long-term outcome of a consecutive series of subscapularis tendon tears repaired arthroscopically","volume":"28","author":"Denard","year":"2012","journal-title":"Arthroscopy"},{"key":"B8","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.aott.2016.07.003","article-title":"The primary factor for suture configuration at rotator cuff repair: width of mattress or distance from tear edge","volume":"50","author":"Hapa","year":"2016","journal-title":"Acta Orthop Traumatol Turc"},{"key":"B9","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.aott.2018.12.006","article-title":"Factors associated with needle breakage of antegrade suture passer and effect of intratendinous remnant needle tip on clinical outcomes after arthroscopic rotator cuff repair","volume":"53","author":"Chung","year":"2019","journal-title":"Acta Orthop Traumatol Turc"},{"key":"B10","doi-asserted-by":"publisher","first-page":"e1263","DOI":"10.1016\/j.asmr.2021.04.005","article-title":"A weaving rip-stop technique leads to a significantly increased load to failure and reduction in suture-tendon cut-through in a biomechanical model of rotator cuff repair","volume":"3","author":"Neeley","year":"2021","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1430","DOI":"10.1016\/j.arthro.2007.10.010","article-title":"Suture passing needle breakage during arthroscopic rotator cuff repair: a complication report","volume":"24","author":"Song","year":"2008","journal-title":"Arthroscopy"},{"key":"B12","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1177\/0363546508314793","article-title":"Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff","volume":"36","author":"Bisson","year":"2008","journal-title":"Am J Sports Med"},{"key":"B13","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1302\/2046-3758.62.BJR-2016-0225.R1","article-title":"Mechanical properties of all-suture anchors for rotator cuff repair","volume":"6","author":"Nagra","year":"2017","journal-title":"Bone Joint Res"},{"key":"B14","doi-asserted-by":"publisher","first-page":"47","DOI":"10.4103\/0973-6042.154760","article-title":"Performance of antegrade suture passers according to tendon thickness","volume":"9","author":"Kim","year":"2015","journal-title":"Int J Shoulder Surg"},{"key":"B15","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1016\/j.tripleo.2008.02.017","article-title":"Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: an evaluation of file flexibility","volume":"105","author":"Gambarini","year":"2008","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"B16","doi-asserted-by":"publisher","first-page":"e99","DOI":"10.1016\/j.eats.2021.09.007","article-title":"Arthroscopic subscapularis repair using 18-gauge spinal needle as a suture passer to eliminate iatrogenic tendon damage from modern suturing devices","volume":"11","author":"Promsang","year":"2022","journal-title":"Arthrosc Tech"},{"key":"B17","doi-asserted-by":"publisher","first-page":"e57","DOI":"10.1016\/j.eats.2019.09.004","article-title":"Arthroscopic, needle-based, transosseous rotator cuff repair","volume":"9","author":"Atoun","year":"2020","journal-title":"Arthrosc Tech"},{"key":"B18","doi-asserted-by":"publisher","first-page":"e7","DOI":"10.1016\/j.eats.2014.09.009","article-title":"Circumferential rotator cuff repair with the n+4 portal, subclavian portal, and high posteromedial portal","volume":"4","author":"Nord","year":"2015","journal-title":"Arthrosc Tech"},{"key":"B19","doi-asserted-by":"publisher","first-page":"457","DOI":"10.5152\/j.aott.2021.21096","article-title":"Comment on \u201cSubacromial space volume in patients with rotator cuff tear: the effect of surgical repair\u201d by Pepe et al","volume":"55","author":"Turan","year":"2021","journal-title":"Acta Orthop Traumatol Turc"},{"key":"B20","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.aott.2018.08.003","article-title":"Subacromial space volume in patients with rotator cuff tear: the effect of surgical repair","volume":"52","author":"Pepe","year":"2018","journal-title":"Acta Orthop Traumatol Turc"},{"key":"B21","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1016\/j.jsams.2016.03.011","article-title":"Reduction of the subacromial space in athletes with and without rotator cuff tendinopathy and its association with the strength of scapular muscles","volume":"19","author":"Leong","year":"2016","journal-title":"J Sci Med Sport"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1977","DOI":"10.1016\/j.jse.2021.05.012","article-title":"Consensus statement on the treatment of massive irreparable rotator cuff tears: a Delphi approach by the Neer Circle of the American Shoulder and Elbow Surgeons","volume":"30","author":"St Pierre","year":"2021","journal-title":"J Shoulder Elbow Surg."}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2022.1065666\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,17]],"date-time":"2023-03-17T16:00:11Z","timestamp":1679068811000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2022.1065666\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,19]]},"references-count":22,"alternative-id":["10.3389\/fsurg.2022.1065666"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2022.1065666","relation":{},"ISSN":["2296-875X"],"issn-type":[{"type":"electronic","value":"2296-875X"}],"subject":[],"published":{"date-parts":[[2022,12,19]]},"article-number":"1065666"}}