{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T03:32:46Z","timestamp":1792985566825,"version":"4.5.0"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T00:00:00Z","timestamp":1662595200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:p>This paper summarizes and analyzes the clinical research progress of the speaking valve in recent years, including the structure and function of the speaking valve, the impact of the speaking valve on the patient\u2019s vocalization or speech, the impact on ventilator weaning and tracheal intubation and extubation, and the effect on aspiration and swallowing function, the impact on patient mobility and quality of life. Related issues in clinical use are also described.<\/jats:p>","DOI":"10.3389\/fsurg.2022.913147","type":"journal-article","created":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T01:43:22Z","timestamp":1662601402000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":17,"title":["Clinical utility and future direction of speaking valve: A review"],"prefix":"10.3389","volume":"9","author":[{"given":"Suna","family":"Lian","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liying","family":"Teng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi","family":"Mao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongying","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,9,8]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"Br Med J"},{"key":"B2","doi-asserted-by":"publisher","first-page":"2177","DOI":"10.1288\/00005537-196812000-00011","article-title":"A tracheotomy speech valve","volume":"78","author":"Toremalm","year":"1968","journal-title":"Laryngoscope"},{"key":"B3","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1007\/s00455-015-9649-7","article-title":"A biomechanical study of hyoid bone and laryngeal movements during swallowing comparing the blom low profile voice inner cannula and Passy-Muir one way tracheotomy tube speaking valves","volume":"30","author":"Srinet","year":"2015","journal-title":"Dysphagia"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1016\/j.jcrc.2015.06.015","article-title":"Speaking valves as part of standard care with tracheostomized mechanically ventilated patients in intensive care unit","volume":"30","author":"Sutt","year":"2015","journal-title":"J Crit Care"},{"key":"B5","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s13054-016-1588-7","article-title":"Patients want to be heard-loud and clear!","volume":"21","author":"Sutt","year":"2017","journal-title":"Crit Care"},{"key":"B6","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1177\/019459988609500224","article-title":"Passy-Muir tracheostomy speaking valve","volume":"95","author":"Passy","year":"1986","journal-title":"Otolaryngol Head Neck Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1288\/00005537-199306000-00013","article-title":"Passy-Muir tracheostomy speaking valve on ventilator-dependent patients","volume":"103","author":"Passy","year":"1993","journal-title":"Laryngoscope"},{"key":"B8","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1097\/00003465-199611000-00003","article-title":"Passy-Muir speaking valve","volume":"15","author":"Kaut","year":"1996","journal-title":"Dimens Crit Care Nurs"},{"key":"B9","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1177\/000348940311200207","article-title":"Physiologic effects of open and closed tracheostomy tubes on the pharyngeal swallow","volume":"112","author":"Gross","year":"2003","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1075","DOI":"10.1097\/CCM.0000000000001610","article-title":"Return of voice for ventilated tracheostomy patients in ICU: a randomized controlled trial of early-targeted intervention","volume":"44","author":"Freeman-Sanderson","year":"2016","journal-title":"Crit Care Med"},{"key":"B11","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1016\/j.jcrc.2014.12.017","article-title":"The use of tracheostomy speaking valves in mechanically ventilated patients results in improved communication and does not prolong ventilation time in cardiothoracic intensive care unit patients","volume":"30","author":"Sutt","year":"2015","journal-title":"J Crit Care"},{"key":"B12","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1097\/00003246-199304000-00009","article-title":"Verbal communication of ventilator-dependent patients","volume":"21","author":"Manzano","year":"1993","journal-title":"Crit Care Med"},{"key":"B13","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jcrc.2017.04.001","article-title":"Ventilation distribution and lung recruitment with speaking valve use in tracheostomised patient weaning from mechanical ventilation in intensive care","volume":"40","author":"Sutt","year":"2017","journal-title":"J Crit Care"},{"key":"B14","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1186\/s13054-016-1249-x","article-title":"Speaking valves in tracheostomised ICU patients weaning off mechanical ventilation\u2013do they facilitate lung recruitment?","volume":"20","author":"Sutt","year":"2016","journal-title":"Crit Care"},{"key":"B15","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1007\/s00455-011-9389-2","article-title":"Deglutitive subglottic air pressure and respiratory system recoil","volume":"27","author":"Gross","year":"2012","journal-title":"Dysphagia"},{"key":"B16","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1177\/000348949610500401","article-title":"Subglottic air pressure: a key component of swallowing efficiency","volume":"105","author":"Eibling","year":"1996","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1177\/0310057X9902700604","article-title":"Pulmonary mechanics in patients with prolonged mechanical ventilation requiring tracheostomy","volume":"27","author":"Lin","year":"1999","journal-title":"Anaesth Intensive Care"},{"key":"B18","doi-asserted-by":"publisher","first-page":"2554","DOI":"10.1044\/2021_AJSLP-20-00377","article-title":"Predictors of aspiration and silent aspiration in patients with new tracheostomy","volume":"30","author":"Marvin","year":"2021","journal-title":"Am J Speech Lang Pathol"},{"key":"B19","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1002\/hed.2880170405","article-title":"Effect of the Passy-Muir Valve on aspiration in patients with tracheostomy","volume":"17","author":"Dettelbach","year":"1995","journal-title":"Head Neck"},{"key":"B20","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1044\/jshr.3803.549","article-title":"Effect of a tracheostomy speaking valve on secretions, arterial oxygenation, and olfaction: a quantitative evaluation","volume":"38","author":"Lichtman","year":"1995","journal-title":"J Speech Hear Res"},{"key":"B21","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1067\/mhl.2000.106941","article-title":"Effect of the Passy-Muir tracheostomy speaking valve on pulmonary aspiration in adults","volume":"29","author":"Elpern","year":"2000","journal-title":"Heart Lung"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1874","DOI":"10.1016\/S0140-6736(09)60658-9","article-title":"Early physical and occupational therapy in mechanically ventilated, critically ill patients: a randomised controlled trial","volume":"373","author":"Schweickert","year":"2009","journal-title":"Lancet"},{"key":"B23","doi-asserted-by":"publisher","first-page":"CD010754","DOI":"10.1002\/14651858.CD010754.pub2","article-title":"Early intervention (mobilization or active exercise) for critically ill adults in the intensive care unit","volume":"3","author":"Doiron","year":"2018","journal-title":"Cochrane Database Syst Rev"},{"key":"B24","doi-asserted-by":"publisher","first-page":"144","DOI":"10.4187\/respcare.06768","article-title":"The effect of speaking valves on ICU mobility of individuals with tracheostomy","volume":"65","author":"Ceron","year":"2020","journal-title":"Respir Care"},{"key":"B25","doi-asserted-by":"publisher","first-page":"216 e1","DOI":"10.1016\/j.jcrc.2012.05.005","article-title":"Tracheostomy teams reduce total tracheostomy time and increase speaking valve use: a systematic review and meta-analysis","volume":"28","author":"Speed","year":"2013","journal-title":"J Crit Care"},{"key":"B26","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1097\/HTR.0b013e3181cd67ea","article-title":"Outcomes of patients with spinal cord injury before and after introduction of an interdisciplinary tracheostomy team","volume":"11","author":"Cameron","year":"2009","journal-title":"Crit Care Resusc"},{"key":"B27","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1097\/HTR.0b013e3181cd67ea","article-title":"Outcome in tracheostomized patients with severe traumatic brain injury following implementation of a specialized multidisciplinary tracheostomy team","volume":"25","author":"LeBlanc","year":"2010","journal-title":"J Head Trauma Rehabil"},{"key":"B28","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1503\/cjs.043209","article-title":"Impact of a specialized multidisciplinary tracheostomy team on tracheostomy care in critically ill patients","volume":"54","author":"de Mestral","year":"2011","journal-title":"Can J Surg"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1693","DOI":"10.1513\/AnnalsATS.202010-1282OC","article-title":"Standard versus accelerated speaking valve placement after percutaneous tracheostomy: a randomized controlled feasibility study","volume":"18","author":"Martin","year":"2021","journal-title":"Ann Am Thorac Soc"},{"key":"B30","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.aucc.2020.09.003","article-title":"The safety and efficacy of prolonged use of one-way speaking valves","volume":"34","author":"O\u2019Connor","year":"2021","journal-title":"Aust Crit Care"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2022.913147\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T01:43:25Z","timestamp":1662601405000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2022.913147\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,8]]},"references-count":30,"alternative-id":["10.3389\/fsurg.2022.913147"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2022.913147","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,8]]},"article-number":"913147"}}