{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T12:42:03Z","timestamp":1789994523418,"version":"4.0.1"},"reference-count":23,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,2,3]],"date-time":"2023-02-03T00:00:00Z","timestamp":1675382400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Femoral neck fracture is a common fracture in orthopedic practice. This study aimed to compare the clinical outcomes between the femoral neck system and dynamic hip system blade for the treatment of femoral neck fracture in young patients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This retrospective study included 43 and 52 patients who underwent treatment for femoral neck fracture with the femoral neck system and dynamic hip system blade, respectively, between August 2019 and August 2020. Operative indexes, including operation duration, blood loss, incision length, postoperative complications (femoral neck shortening, non-union, screw pull-out, femoral head necrosis), and Harris scale scores were recorded and analyzed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Compared to that with the dynamic hip system blade, the femoral neck system showed significantly less operation duration (femoral neck system vs. dynamic hip system blade: 47.09\u2009\u00b1\u20099.19 vs. 52.90\u2009\u00b1\u20099.64, <jats:italic>P<\/jats:italic>\u2009=\u20090.004), less blood loss (48.53\u2009\u00b1\u200910.69 vs. 65.31\u2009\u00b1\u200917.91, <jats:italic>P<\/jats:italic>\u2009&amp;lt;\u20090.001), and shorter incision length (4.04\u2009\u00b1\u20090.43 vs. 4.93\u2009\u00b1\u20090.53, <jats:italic>P<\/jats:italic>\u2009&amp;lt;\u20090.001). Femoral neck shortening was significantly lower with the femoral neck system than with the dynamic hip system blade (3.93\u2009\u00b1\u20092.40, <jats:italic>n<\/jats:italic>\u2009=\u200939 vs. 5.22\u2009\u00b1\u20092.89, <jats:italic>n<\/jats:italic>\u2009=\u200944, <jats:italic>P<\/jats:italic>\u2009=\u20090.031). No statistical differences were observed between the two groups in nonunion, screw pull-out, and femoral head necrosis. In addition, the latest follow-up Harris scale score was significantly higher with the femoral neck system than with the dynamic hip system blade (92.3\u2009\u00b1\u20094.5 vs. 89. 9\u2009\u00b1\u20094.9, <jats:italic>P<\/jats:italic>\u2009=\u20090.015).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The femoral neck system results in less trauma, less femoral neck shortening, and better hip joint function than the dynamic hip system blade for the treatment of femoral neck fracture in young patients.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fsurg.2023.1092786","type":"journal-article","created":{"date-parts":[[2023,2,3]],"date-time":"2023-02-03T05:25:04Z","timestamp":1675401904000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of femoral neck system vs. dynamic hip system blade for the treatment of femoral neck fracture in young patients: A retrospective study"],"prefix":"10.3389","volume":"10","author":[{"given":"Zilu","family":"Ge","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunfeng","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Limin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guanglin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,2,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e448","DOI":"10.5435\/jaaos-d-17-00497","article-title":"Diagnosis and management of ipsilateral femoral neck and shaft fractures","volume":"26","author":"Jones","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"key":"B2","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1097\/bot.0000000000000014","article-title":"Fracture morphology of high shear angle \u201cvertical\u201d femoral neck fractures in young adult patients","volume":"28","author":"Collinge","year":"2014","journal-title":"J Orthop Trauma"},{"key":"B3","doi-asserted-by":"publisher","first-page":"S20","DOI":"10.1097\/bot.0000000000001367","article-title":"Technologies for young femoral neck fracture fixation","volume":"33","author":"Duffin","year":"2019","journal-title":"J Orthop Trauma"},{"key":"B4","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/bot.0000000000000291","article-title":"Femoral neck fractures: current management","volume":"29","author":"Florschutz","year":"2015","journal-title":"J Orthop Trauma"},{"key":"B5","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1097\/00005373-196411000-00001","article-title":"Trochanteric fractures treated by the sliding screw plate fixation method","volume":"4","author":"Clawson","year":"1964","journal-title":"J Trauma"},{"key":"B6","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1302\/0301-620x.93b5.25539","article-title":"Dynamic hip screw versus DHS blade: a biomechanical comparison of the fixation achieved by each implant in bone","volume":"93","author":"O'Neill","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"B7","first-page":"275","article-title":"Effect of dynamic hip system blade on the treatment of femoral neck fractures in elderly patients with osteoporosis","volume":"17","author":"Zhao","year":"2014","journal-title":"Chin J Traumatol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/bot.0000000000000739","article-title":"Biomechanical evaluation of the femoral neck system in unstable pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws","volume":"31","author":"Stoffel","year":"2017","journal-title":"J Orthop Trauma"},{"key":"B9","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1186\/s13018-021-02517-z","article-title":"Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients","volume":"16","author":"Hu","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"B10","doi-asserted-by":"publisher","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","article-title":"Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation","volume":"51","author":"Harris","year":"1969","journal-title":"J Bone Joint Surg Am"},{"key":"B11","doi-asserted-by":"publisher","first-page":"297","DOI":"10.5435\/jaaos-d-15-00661","article-title":"Femoral neck fractures in adults treated with internal fixation: a prospective multicenter Chinese cohort","volume":"25","author":"Slobogean","year":"2017","journal-title":"J Am Acad Orthop Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1302\/0301-620x.90b11.20582","article-title":"The effect of shortening and varus collapse of the femoral neck on function after fixation of intracapsular fracture of the hip: a multi-centre cohort study","volume":"90","author":"Zlowodzki","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"B13","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/01.ta.0000241143.71274.63","article-title":"Femoral neck shortening after fracture fixation with multiple cancellous screws: incidence and effect on function","volume":"64","author":"Zlowodzki","year":"2008","journal-title":"J Trauma"},{"key":"B14","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1016\/j.injury.2014.11.015","article-title":"Gaps and opportunities in the management of the young femoral neck fracture","volume":"46","author":"Della Rocca","year":"2015","journal-title":"Injury"},{"key":"B15","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s13018-019-1097-x","article-title":"Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis","volume":"14","author":"Li","year":"2019","journal-title":"J Orthop Surg Res."},{"key":"B16","doi-asserted-by":"publisher","first-page":"2081","DOI":"10.1016\/j.injury.2016.07.030","article-title":"Augmentation by cerclage wire improves fixation of vertical shear femoral neck fractures-A biomechanical analysis","volume":"47","author":"Kuan","year":"2016","journal-title":"Injury"},{"key":"B17","doi-asserted-by":"publisher","first-page":"681","DOI":"10.21037\/atm-19-3344","article-title":"Comparative study of Pauwels type III femoral neck fractures managed by short dynamic hip screw with fibula bone graft or cannulated screws in young adults","volume":"8","author":"Li","year":"2020","journal-title":"Ann Transl Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/j.aott.2017.07.006","article-title":"Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: a retrospective study","volume":"51","author":"Chen","year":"2017","journal-title":"Acta Orthop Traumatol Turc"},{"key":"B19","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","article-title":"Complications following young femoral neck fractures","volume":"46","author":"Slobogean","year":"2015","journal-title":"Injury"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.2106\/jbjs.g.01353","article-title":"Results of internal fixation of pauwels type-3 vertical femoral neck fractures","volume":"90","author":"Liporace","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"B21","doi-asserted-by":"publisher","first-page":"e293","DOI":"10.1097\/bot.0000000000000351","article-title":"Incidence, magnitude, and predictors of shortening in young femoral neck fractures","volume":"29","author":"Stockton","year":"2015","journal-title":"J Orthop Trauma"},{"key":"B22","first-page":"2254","article-title":"Treatment of femoral neck fractures in young adults","volume":"90","author":"Ly","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"B23","first-page":"300","article-title":"Vertical shear fractures of the femoral neck. A biomechanical study","author":"Baitner","year":"1999","journal-title":"Clin Orthop Relat Res"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2023.1092786\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,3]],"date-time":"2023-02-03T05:25:08Z","timestamp":1675401908000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2023.1092786\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,3]]},"references-count":23,"alternative-id":["10.3389\/fsurg.2023.1092786"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2023.1092786","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,3]]},"article-number":"1092786"}}