{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T21:53:10Z","timestamp":1774389190637,"version":"3.50.1"},"reference-count":42,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,8,7]],"date-time":"2023-08-07T00:00:00Z","timestamp":1691366400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec><jats:title>Research objective<\/jats:title><jats:p>To propose a technique for placing pedicle screws in the thoracic spine using the Supraspinous ligament Arc Tangent (SLAT) as a guide to increase the safety and stability of screw placement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Content and methods<\/jats:title><jats:p>A retrospective analysis of postoperative anteroposterior and lateral x-ray images was performed for 118 patients with thoracic spine diseases who received conventional freehand technique from January 2016 to May 2020 and SLAT-guided technique since June 2020 to present. The diagnoses included thoracic spinal stenosis, deformity, fractures, infections, and tumors. The angle between the screw and the upper endplate was categorized as grade 1 (0\u00b0\u20135\u00b0), grade 2 (5\u00b0\u201310\u00b0), and grade 3 (&amp;gt;10\u00b0). Three surgeons with more than 10 years of experience in spinal surgery measured the angle between the screw and the upper endplate in the lateral view. Chi-square test was used for statistical analysis, and <jats:italic>p<\/jats:italic>\u2009&amp;lt;\u20090.05 was considered statistically significant.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of 1315 pedicle screws were placed from T1 to T12 in all patients. In the conventional freehand technique group, 549 screws were grade 1, 35 screws were grade 2, and 23 screws were grade 3. In the SLAT-guided freehand technique group, 685 screws were grade 1, 15 screws were grade 2, and 8 screws were grade 3. The data of each group was <jats:italic>p<\/jats:italic>\u2009&amp;lt;\u20090.05 by Chi-squared test, which was statistically significant, indicating that the SLAT-guided freehand technique resulted in a higher rate of parallelism between the screws and the upper endplate. All patients underwent intraoperative neurophysiological monitoring, immediate postoperative neurological examination, postoperative x-ray examination, and assess the eventual recovery. The screws were safe and stable, and no complications related to pedicle screw placement were found.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The SLAT-guided freehand technique for placing pedicle screws in the thoracic spine can achieve a higher rate of screw-upper endplate parallelism, making screw placement safer and more accurate. Our method provides a convenient and reliable technique for most spinal surgeons, allowing for increased accuracy and safety with less fluoroscopic guidance.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fsurg.2023.1219816","type":"journal-article","created":{"date-parts":[[2023,8,7]],"date-time":"2023-08-07T20:50:25Z","timestamp":1691441425000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Supraspinous ligament arc tangent guided freehand thoracic pedicle screw insertion technique: high parallelism between screws and upper endplate"],"prefix":"10.3389","volume":"10","author":[{"given":"Fushuai","family":"Peng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhensong","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingtong","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yudong","family":"Lai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haoyu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xingpeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,8,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1097\/00003086-198602000-00003","article-title":"Internal fixation of the lumbar spine with pedicle screw plating","volume":"203","author":"Roy-Camille","year":"1986","journal-title":"Clin Orthop Relat Res"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.22603\/ssrr.2021-0059","article-title":"Historical note: the evolution of cortical bone trajectory and associated techniques","volume":"6","author":"Kim","year":"2022","journal-title":"Spine Surg Relat Res"},{"key":"B3","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/S0030-5898(20)30425-9","article-title":"Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates","volume":"17","author":"Roy-Camille","year":"1986","journal-title":"Orthop Clin North Am"},{"key":"B4","doi-asserted-by":"publisher","first-page":"88","DOI":"10.3171\/jns.1984.60.1.0088","article-title":"Treatment of pedicular fractures of the axis. A clinical study and screw fixation technique","volume":"60","author":"Borne","year":"1984","journal-title":"J Neurosurg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"678","DOI":"10.3892\/etm.2013.914","article-title":"Efficacy analysis of pedicle screw internal fixation of fractured vertebrae in the treatment of thoracolumbar fractures","volume":"5","author":"Huang","year":"2013","journal-title":"Exp Ther Med"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1558","DOI":"10.1097\/00007632-200207150-00015","article-title":"Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities","volume":"27","author":"Belmont","year":"2002","journal-title":"Spine"},{"key":"B7","doi-asserted-by":"publisher","first-page":"2040","DOI":"10.1097\/01.brs.0000138268.12324.1a","article-title":"Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis","volume":"29","author":"Kim","year":"2004","journal-title":"Spine"},{"key":"B8","first-page":"157","article-title":"Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine","volume":"67","author":"Liljenqvist","year":"2001","journal-title":"Acta Orthop Belg"},{"key":"B9","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1007\/s00586-002-0415-9","article-title":"Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis","volume":"11","author":"Liljenqvist","year":"2002","journal-title":"Eur Spine J"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2239","DOI":"10.1097\/00007632-199710010-00008","article-title":"Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis","volume":"22","author":"Liljenqvist","year":"1997","journal-title":"Spine"},{"key":"B11","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/BF02107905","article-title":"Morphometric analysis of the thoracolumbar and lumbar pedicles, anatomo-radiologic study","volume":"10","author":"Marchesi","year":"1988","journal-title":"Surg Radiol Anat"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1390","DOI":"10.1097\/00007632-199406000-00014","article-title":"Morphometric study of the pedicles of thoracic and lumbar vertebrae in Koreans","volume":"19","author":"Kim","year":"1994","journal-title":"Spine"},{"key":"B13","doi-asserted-by":"publisher","first-page":"778","DOI":"10.3171\/2014.7.SPINE1489","article-title":"Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: preliminary clinical experience","volume":"21","author":"Fennell","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"B14","doi-asserted-by":"publisher","first-page":"522","DOI":"10.3944\/AOTT.2009.522","article-title":"The safety of pedicle screw fixation in the thoracic spine","volume":"43","author":"Yalniz","year":"2009","journal-title":"Acta Orthop Traumatol Turc"},{"key":"B15","doi-asserted-by":"publisher","first-page":"e11560","DOI":"10.1097\/MD.0000000000011560","article-title":"Complications of percutaneous pedicle screw fixation in treating thoracolumbar and lumbar fracture","volume":"97","author":"Zhao","year":"2018","journal-title":"Medicine"},{"key":"B16","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1097\/00007632-199702010-00001","article-title":"Projection of the thoracic pedicle and its morphometric analysis","volume":"22","author":"Ebraheim","year":"1997","journal-title":"Spine"},{"key":"B17","doi-asserted-by":"publisher","first-page":"2491","DOI":"10.1007\/s00586-020-06479-4","article-title":"Pedicle screw fixation of thoracolumbar fractures: conventional short segment versus short segment with intermediate screws at the fracture level-a systematic review and meta-analysis","volume":"29","author":"Kapoen","year":"2020","journal-title":"Eur Spine J"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1007\/s00586-015-3768-6","article-title":"Pedicle screw loosening: a clinically relevant complication?","volume":"24","author":"Galbusera","year":"2015","journal-title":"Eur Spine J"},{"key":"B19","doi-asserted-by":"publisher","first-page":"S80","DOI":"10.1097\/BPO.0000000000001828","article-title":"Screw malposition: are there long-term repercussions to malposition of pedicle screws?","volume":"41","author":"Amaral","year":"2021","journal-title":"J Pediatr Orthop"},{"key":"B20","doi-asserted-by":"publisher","first-page":"2995","DOI":"10.1111\/os.13513","article-title":"SAP Principle guided free hand technique: a secret for T1 to S1 pedicle screw placement","volume":"14","author":"He","year":"2022","journal-title":"Orthop Surg"},{"key":"B21","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.ijsu.2018.01.006","article-title":"Sagittal orientation and uniform entry for thoracic pedicle screw placement with free-hand technique: a retrospective study on 382 pedicle screws","volume":"51","author":"Gokcen","year":"2018","journal-title":"Int J Surg"},{"key":"B22","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s13018-015-0225-5","article-title":"Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device","volume":"10","author":"Yoshii","year":"2015","journal-title":"J Orthop Surg Res"},{"key":"B23","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3171\/2013.11.SPINE13413","article-title":"The accuracy of pedicle screw placement using intraoperative image guidance systems","volume":"20","author":"Mason","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"B24","doi-asserted-by":"publisher","first-page":"726","DOI":"10.7507\/1002-1892.20160148","article-title":"Short-term effectiveness of percutaneous pedicle screw guided with photoelectric navigation for thoracolumbar fractures","volume":"30","author":"Cao","year":"2016","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"B25","doi-asserted-by":"publisher","first-page":"E348","DOI":"10.1097\/BRS.0000000000002341","article-title":"Preparation and assessment of an individualized navigation template for lower cervical anterior transpedicular screw insertion using a three-dimensional printing technique","volume":"43","author":"Li","year":"2018","journal-title":"Spine"},{"key":"B26","doi-asserted-by":"publisher","first-page":"e24636","DOI":"10.1097\/MD.0000000000024636","article-title":"Application of 3-dimensional printing technology combined with guide plates for thoracic spinal tuberculosis","volume":"100","author":"Wang","year":"2021","journal-title":"Medicine"},{"key":"B27","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1111\/os.12453","article-title":"Guideline for thoracolumbar pedicle screw placement assisted by orthopaedic surgical robot","volume":"11","author":"Tian","year":"2019","journal-title":"Orthop Surg"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1882","DOI":"10.1097\/BRS.0000000000001099","article-title":"Accuracy of pedicle screw placement with robotic guidance system: a cadaveric study","volume":"40","author":"Fujishiro","year":"2015","journal-title":"Spine"},{"key":"B29","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1227\/NEU.0b013e3181fdfaf4","article-title":"Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws","volume":"68","author":"Parker","year":"2011","journal-title":"Neurosurgery"},{"key":"B30","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","article-title":"Accuracy of current techniques for placement of pedicle screws in the spine: a comprehensive systematic review and meta-analysis of 51,161 screws","volume":"126","author":"Perdomo-Pantoja","year":"2019","journal-title":"World Neurosurg"},{"key":"B31","doi-asserted-by":"publisher","first-page":"256","DOI":"10.4103\/jnrp.jnrp_183_18","article-title":"Is freehand technique of pedicle screw insertion in thoracolumbar spine safe and accurate? Assessment of 250 screws","volume":"10","author":"Vijayeswaran","year":"2019","journal-title":"J Neurosci Rural Pract"},{"key":"B32","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1097\/01.BRS.0000109983.12113.9B","article-title":"Free hand pedicle screw placement in the thoracic spine: is it safe?","volume":"29","author":"Kim","year":"2004","journal-title":"Spine"},{"key":"B33","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1097\/BSD.0b013e3181453dc6","article-title":"Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe?","volume":"21","author":"Karapinar","year":"2008","journal-title":"J Spinal Disord Tech"},{"key":"B34","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1007\/s00264-008-0535-x","article-title":"Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique","volume":"33","author":"Modi","year":"2009","journal-title":"Int Orthop"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1830","DOI":"10.1007\/s11999-010-1280-1","article-title":"Accuracy of thoracic pedicle screw using ideal pedicle entry point in severe scoliosis","volume":"468","author":"Modi","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"B36","doi-asserted-by":"publisher","first-page":"468","DOI":"10.4103\/0028-3886.284379","article-title":"Accuracy of the freehand (fennell) technique using a uniform entry point and sagittal trajectory for insertion of thoracic pedicle screws: a computed tomography-based virtual simulation study","volume":"68","author":"Swaminathan","year":"2020","journal-title":"Neurol India"},{"key":"B37","doi-asserted-by":"publisher","first-page":"e501","DOI":"10.7759\/cureus.501","article-title":"Freehand thoracic pedicle screw placement: review of existing strategies and a step-by-step guide using uniform landmarks for all levels","volume":"8","author":"Avila","year":"2016","journal-title":"Cureus"},{"key":"B38","doi-asserted-by":"publisher","first-page":"64","DOI":"10.7555\/JBR.27.20130051","article-title":"A new free-hand pedicle screw placement technique with reference to the supraspinal ligament","volume":"28","author":"Li","year":"2014","journal-title":"J Biomed Res"},{"key":"B39","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1111\/os.12599","article-title":"Freehand pedicle screw placement using a universal entry point and sagittal and axial trajectory for all subaxial cervical, thoracic and lumbosacral spines","volume":"12","author":"Zhang","year":"2020","journal-title":"Orthop Surg"},{"key":"B40","doi-asserted-by":"publisher","first-page":"e9907","DOI":"10.1097\/MD.0000000000009907","article-title":"Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine","volume":"97","author":"Kim","year":"2018","journal-title":"Medicine"},{"key":"B41","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1186\/s12891-021-04254-0","article-title":"Comparison of three different screw trajectories in osteoporotic vertebrae: a biomechanical investigation","volume":"22","author":"Jarvers","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"B42","doi-asserted-by":"publisher","first-page":"372","DOI":"10.23736\/S0390-5616.16.03670-5","article-title":"Accuracy of plain radiographs to identify wrong positioned free hand pedicle screw in the deformed spine","volume":"63","author":"Piazzolla","year":"2019","journal-title":"J Neurosurg Sci"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2023.1219816\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,7]],"date-time":"2023-08-07T20:50:30Z","timestamp":1691441430000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2023.1219816\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,7]]},"references-count":42,"alternative-id":["10.3389\/fsurg.2023.1219816"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2023.1219816","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,7]]},"article-number":"1219816"}}