{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,7]],"date-time":"2025-08-07T20:32:26Z","timestamp":1754598746989,"version":"3.41.2"},"reference-count":27,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T00:00:00Z","timestamp":1711065600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Bicortical screw fixation, which penetrates and fixes the near and far cortex of bone, has been conventionally used to achieve compressive fixation for fracture using screws. Open reduction and internal fixation using the locking plate are widely used for treating proximal humerus fractures. However, minimal contact between the bone and the locking plate can lead to an insufficient reduction. Theoretically, a dual-lead locking screw with different leads for the screw head and body could enhance the reduction and fixation stability of fragments in proximal humeral fractures without bicortical fixation, and achieve additional compression at the bone-plate-screw interface. This study assessed the insertion mechanics of the lead ratio of the dual-lead locking screw and its effect on the fixation stability of the proximal humerus fracture.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A Multi-Fix\u00ae locking plating system composed of <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM1\"><mml:mi mathvariant=\"normal\">\u2205<\/mml:mi><\/mml:math><\/jats:inline-formula> 3.5\u2005mm locking screws and a locking plate was used to make a locked plating for Sawbone bone blocks and fourth-generation composite humeri. Two different types of Sawbone bone blocks were used to simulate the osteoporotic (10 PCF) and normal cancellous (20 PCF) bones. The lead of the screw head thread (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM2\"><mml:msub><mml:mi>L<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">head<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><\/mml:math><\/jats:inline-formula>) was 0.8\u2005mm, and that of the screw body (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM3\"><mml:msub><mml:mi>L<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">body<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><\/mml:math><\/jats:inline-formula>) was 0.8, 1.25, 1.6, 2.0, and 2.4\u2005mm, whose lead ratios (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM4\"><mml:msub><mml:mi>R<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">lead<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mo>=<\/mml:mo><mml:msub><mml:mi>L<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">body<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mrow><mml:mo>\/<\/mml:mo><\/mml:mrow><mml:msub><mml:mi>L<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">head<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><\/mml:math><\/jats:inline-formula>) were 1.0, 1.56, 2.0, 2.5, and 3.0, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The dual-lead locking screw elevated the compression between the locking plate and the bone. The elevation in the compression due to the dual-lead thread became weaker for the cancellous bone when the lead of the screw body was more than twice that of the screw head. The plate\/humerus compression with strong bone quality withstood higher dual-lead-driven compression.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>A dual-lead locking screw of <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM5\"><mml:msub><mml:mi>L<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">body<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mo>=<\/mml:mo><mml:mn>1.25<\/mml:mn><mml:mspace width=\"thinmathspace\"\/><mml:mrow><mml:mi mathvariant=\"normal\">mm<\/mml:mi><\/mml:mrow><\/mml:math><\/jats:inline-formula> (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM6\"><mml:msub><mml:mi>R<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">lead<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mo>=<\/mml:mo><mml:mn>1.56<\/mml:mn><\/mml:math><\/jats:inline-formula>) is recommended for maximum rotational stability for the locked humerus plating. The screws with over <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM7\"><mml:msub><mml:mi>L<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">body<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mo>=<\/mml:mo><mml:mn>1.6<\/mml:mn><mml:mspace width=\"thinmathspace\"\/><mml:mrow><mml:mi mathvariant=\"normal\">mm<\/mml:mi><\/mml:mrow><\/mml:math><\/jats:inline-formula> (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM8\"><mml:msub><mml:mi>R<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">lead<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mo>=<\/mml:mo><mml:mn>2<\/mml:mn><\/mml:math><\/jats:inline-formula>) have no advantage in terms of the failure torque and maximum torsional deformation. Any locking dual-lead screw with a body thread lead of &amp;lt;1.6\u2005mm (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM9\"><mml:msub><mml:mi>R<\/mml:mi><mml:mrow><mml:mrow><mml:mi mathvariant=\"normal\">lead<\/mml:mi><\/mml:mrow><\/mml:mrow><\/mml:msub><mml:mo>=<\/mml:mo><mml:mn>2<\/mml:mn><\/mml:math><\/jats:inline-formula>) can be used without the risk of bone crush when surgeons require additional compression to the locked cancellous bone plating.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fsurg.2024.1333670","type":"journal-article","created":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T04:38:48Z","timestamp":1711082328000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["The application of a dual-lead locking screw could enhance the reduction and fixation stability of the proximal humerus fractures: a biomechanical evaluation"],"prefix":"10.3389","volume":"11","author":[{"given":"Eunju","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyeon Jang","family":"Jeong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yeon Soo","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joo Han","family":"Oh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2024,3,22]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"448","DOI":"10.4055\/jkoa.2010.45.6.448","article-title":"Minimally invasive plate osteosynthesis of proximal, middle and distal humerus fractures","volume":"45","author":"Shin","year":"2010","journal-title":"J Korean Orthop Assoc"},{"key":"B2","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/00003086-200402000-00008","article-title":"Nonunions of the humerus","volume":"419","author":"Volgas","year":"2004","journal-title":"Clin Orthop Relat Res"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1327","DOI":"10.1016\/j.injury.2013.05.008","article-title":"Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures","volume":"44","author":"R\u00f6derer","year":"2013","journal-title":"Injury"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1931","DOI":"10.1016\/j.jse.2017.05.003","article-title":"Defining optimal calcar screw positioning in proximal humerus fracture fixation","volume":"26","author":"Padegimas","year":"2017","journal-title":"J Shoulder Elbow Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1186\/s13287-018-0995-x","article-title":"Osteogenesis and aging: lessons from mesenchymal stem cells","volume":"9","author":"Infante","year":"2018","journal-title":"Stem Cell Res Ther"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-015-0338-x","article-title":"Meta-analysis of locking plate versus intramedullary nail for treatment of proximal humeral fractures","volume":"10","author":"Wang","year":"2015","journal-title":"J Orthop Surg Res"},{"key":"B7","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1097\/01.ta.0000195462.53525.0c","article-title":"Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques","volume":"60","author":"Fulkerson","year":"2006","journal-title":"J Trauma Acute Care Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1080\/00016470410004120","article-title":"Internal fixation of proximal humeral fractures with a locking compression plate A retrospective evaluation of 72 patients followed for a minimum of 1 year","volume":"75","author":"Bj\u00f6rkenheim","year":"2004","journal-title":"Acta Orthop Scand"},{"first-page":"S17","year":"2010","author":"Cronier","key":"B9"},{"key":"B10","doi-asserted-by":"publisher","first-page":"92","DOI":"10.12671\/jkfs.2013.26.1.92","article-title":"Selection of plate in internal fixation of fractures: locking plate and compression plate","volume":"26","author":"Park","year":"2013","journal-title":"J Korean Fract Soc"},{"key":"B11","doi-asserted-by":"publisher","first-page":"143","DOI":"10.5397\/CiSE.2008.11.2.143","article-title":"Comparison of radiologic and clinical results between locking compression plate and unlocked plate in proximal humerus fractures","volume":"11","author":"Kim","year":"2008","journal-title":"Clin Shoulder Elbow"},{"key":"B12","doi-asserted-by":"publisher","first-page":"187","DOI":"10.12671\/jkfs.2010.23.2.187","article-title":"Surgical treatment of pathologic humeral fracture","volume":"23","author":"Kang","year":"2010","journal-title":"J Korean Fract Soc"},{"key":"B13","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","article-title":"Biomechanics of locked plates and screws","volume":"18","author":"Egol","year":"2004","journal-title":"J Orthop Trauma"},{"key":"B14","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1115\/1.2796022","article-title":"Factors affecting the pullout strength of cancellous bone screws","volume":"118","author":"Chapman","year":"1996","journal-title":"J Biomech Eng"},{"key":"B15","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.injury.2009.08.015","article-title":"Holding power of variable pitch screws in osteoporotic, osteopenic and normal bone: are all screws created equal?","volume":"41","author":"Ramaswamy","year":"2010","journal-title":"Injury"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1850","DOI":"10.4103\/0366-6999.186645","article-title":"Biomechanical study of the fixation strength of anteromedial plating for humeral shaft fractures","volume":"129","author":"Zheng","year":"2016","journal-title":"Chin Med J"},{"key":"B17","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.clinbiomech.2015.12.005","article-title":"Anatomical and biomechanical evaluation of an intramedullary nail for fractures of proximal humerus fractures based on tuberosity fixation","volume":"32","author":"Clavert","year":"2016","journal-title":"Clin Biomech"},{"key":"B18","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.jse.2009.11.003","article-title":"Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation","volume":"19","author":"Schumer","year":"2010","journal-title":"J Shoulder Elbow Surg"},{"key":"B19","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/j.clinbiomech.2010.01.009","article-title":"Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: the role of implant stiffness","volume":"25","author":"Foruria","year":"2010","journal-title":"Clin Biomech"},{"key":"B20","doi-asserted-by":"publisher","first-page":"94","DOI":"10.12671\/jkfs.2012.25.1.94","article-title":"The current concepts in the treatment of proximal humerus fracture","volume":"25","author":"Oh","year":"2012","journal-title":"J Korean Fract Soc"},{"key":"B21","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s12938-018-0479-3","article-title":"Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review","volume":"17","author":"Jabran","year":"2018","journal-title":"Biomed Eng Online"},{"key":"B22","doi-asserted-by":"publisher","first-page":"109","DOI":"10.5435\/00124635-200303000-00005","article-title":"Internal fracture fixation in patients with osteoporosis","volume":"11","author":"Cornell","year":"2003","journal-title":"J Am Acad Orthop Surg"},{"key":"B23","doi-asserted-by":"publisher","first-page":"e0145949","DOI":"10.1371\/journal.pone.0145949","article-title":"Impact of different screw designs on durability of fracture fixation: in vitro study with cyclic loading of scaphoid bones","volume":"11","author":"Gruszka","year":"2016","journal-title":"PloS One"},{"key":"B24","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1016\/j.jse.2012.08.018","article-title":"Proximal humerus cortical bone thickness correlates with bone mineral density and can clinically rule out osteoporosis","volume":"22","author":"Mather","year":"2013","journal-title":"J Shoulder Elbow Surg"},{"key":"B25","doi-asserted-by":"publisher","first-page":"6140","DOI":"10.3390\/jcm11206140","article-title":"Management of proximal humerus fractures in adults\u2014a scoping review","volume":"11","author":"Baker","year":"2022","journal-title":"J Clin Med"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1016\/j.clinbiomech.2014.08.013","article-title":"Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges","volume":"29","author":"Gaudelli","year":"2014","journal-title":"Clin Biomech"},{"key":"B27","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1016\/j.jseint.2020.07.022","article-title":"Factors associated with maintaining reduction following locking plate fixation of proximal humerus fractures: a population-based retrospective cohort study","volume":"4","author":"Bouliane","year":"2020","journal-title":"JSES Intl"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2024.1333670\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T04:38:53Z","timestamp":1711082333000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2024.1333670\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,22]]},"references-count":27,"alternative-id":["10.3389\/fsurg.2024.1333670"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2024.1333670","relation":{},"ISSN":["2296-875X"],"issn-type":[{"type":"electronic","value":"2296-875X"}],"subject":[],"published":{"date-parts":[[2024,3,22]]},"article-number":"1333670"}}