{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T21:08:10Z","timestamp":1770325690915,"version":"3.49.0"},"reference-count":34,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T00:00:00Z","timestamp":1729728000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:p>Percutaneous vertebroplasty (PVP), a minimally invasive surgery technique, has become the common treatment for osteoporotic vertebral compression fractures (OVCF). The complications of PVP will lead to severe damage to spinal neuro systems due to bone cement leakage. A patient tailored preoperative assessment approach was developed to reduce the risks of complications in this study. The porcine OVCF model was fabricated to mimic the patient vertebral fracture <jats:italic>in vitro<\/jats:italic> using decalcification process. The 3D reconstructed model based on the imagological examination data acquired from the porcine vertebral bone was implemented for finite element (FE) simulation. The vertebral body with bone cement injected was scanned using CT for comparison with the finite element simulation results. This study showed a practical method for predicting the flow of bone cement in OVCF, which enabled the surgeons to evaluate the bone cement flow during preoperative assessment to reduce the cement leakage risks.<\/jats:p>","DOI":"10.3389\/fsurg.2024.1444817","type":"journal-article","created":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T05:10:26Z","timestamp":1729746626000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Development of patient-tailored preoperative assessment of percutaneous vertebroplasty"],"prefix":"10.3389","volume":"11","author":[{"given":"Yian","family":"Lu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qunhua","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2024,10,24]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.jocn.2013.05.017","article-title":"Percutaneous vertebroplasty compared with conservative treatment in patients with chronic painful osteoporotic spinal fractures","volume":"21","author":"Chen","year":"2014","journal-title":"J Clin Neurosci"},{"key":"B2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.3969\/j.issn.1672-2957.2020.03.010","article-title":"Influence of different kinds of surgical procedures on postoperative outcome and cervical sagittal parameters of patients with cervical spondylotic myelopathy complicated with spinal stenosis","volume":"18","author":"Guo","year":"2020","journal-title":"J Spine Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1097\/BRS.0b013e3181a4e628","article-title":"Percutaneous vertebroplasty compared to conservative treatment in patients with painful acute or subacute osteoporotic vertebral fractures: three-months follow-up in a clinical randomized study","volume":"34","author":"Rousing","year":"2009","journal-title":"Spine"},{"key":"B4","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1007\/s00330-004-2549-0","article-title":"Percutaneous vertebroplasty immediately relieves pain of osteoporotic vertebral compression fractures and prevents prolonged immobilization of patients","volume":"15","author":"Kobayashi","year":"2005","journal-title":"Eur Radiol"},{"key":"B5","doi-asserted-by":"publisher","first-page":"642","DOI":"10.3174\/ajnr.A0918","article-title":"Vertebroplasty in multiple myeloma: outcomes in a large patient series","volume":"29","author":"McDonald","year":"2008","journal-title":"Am J Neuroradiol"},{"key":"B6","doi-asserted-by":"publisher","first-page":"2309","DOI":"10.1007\/s00264-014-2470-3","article-title":"Treatment of multiple osteoporotic vertebral compression fractures by percutaneous cement augmentation","volume":"38","author":"Saracen","year":"2014","journal-title":"Int Orthop"},{"key":"B7","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/j.crad.2004.01.001","article-title":"Percutaneous vertebroplasty: history, technique and current perspectives","volume":"59","author":"Hide","year":"2004","journal-title":"Clin Radiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1023\/B:JMSM.0000010101.45352.d1","article-title":"Thermal characterization of PMMA-based bone cement curing","volume":"15","author":"Li","year":"2004","journal-title":"J Mater Sci Mater Med"},{"key":"B9","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/j.wneu.2017.01.124","article-title":"Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence","volume":"101","author":"Zhan","year":"2017","journal-title":"World Neurosurg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"e222535","DOI":"10.1148\/radiol.222535","article-title":"Vertebroplasty versus active control intervention for chronic osteoporotic vertebral compression fractures: the VERTOS V randomized controlled trial","volume":"308","author":"Carli","year":"2023","journal-title":"Radiology"},{"key":"B11","doi-asserted-by":"publisher","first-page":"E419","DOI":"10.1097\/00007632-200210010-00022","article-title":"Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report","volume":"27","author":"Lee","year":"2002","journal-title":"Spine"},{"key":"B12","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1186\/s13018-019-1459-4","article-title":"Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty","volume":"14","author":"Hsieh","year":"2019","journal-title":"J Orthop Surg"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1728","DOI":"10.1097\/BRS.0b013e3180dc9c36","article-title":"Neurologic deficit following percutaneous vertebral stabilization","volume":"32","author":"Patel","year":"2007","journal-title":"Spine"},{"key":"B14","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1016\/j.ejcts.2007.12.012","article-title":"Multiple cardiac perforations and pulmonary embolism caused by cement leakage after percutaneous vertebroplasty","volume":"33","author":"Lim","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"key":"B15","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1097\/BRS.0000000000003773","article-title":"Risk factors for cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: an analysis of 1456 vertebrae augmented by low-viscosity bone cement","volume":"46","author":"Tang","year":"2021","journal-title":"Spine"},{"key":"B16","doi-asserted-by":"publisher","first-page":"812023","DOI":"10.3389\/fpubh.2021.812023","article-title":"Machine learning applications for the prediction of bone cement leakage in percutaneous vertebroplasty","volume":"9","author":"Li","year":"2021","journal-title":"Front Public Health"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1111\/papr.12561","article-title":"Failed percutaneous vertebroplasty due to insufficient correction of intravertebral instability in Kummell\u2019s disease: a case report","volume":"17","author":"Kim","year":"2017","journal-title":"Pain Pract"},{"key":"B18","doi-asserted-by":"publisher","first-page":"E33","DOI":"10.36076\/ppj.2018.1.E33","article-title":"Risk factors for the occurrence of InsufficientCement distribution in the fractured area afterPercutaneous vertebroplasty in OsteoporoticVertebral compression fractures","volume":"1","author":"Jiang","year":"2018","journal-title":"Pain Physician"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1536","DOI":"10.3390\/medicina59091536","article-title":"Complications of percutaneous vertebroplasty: a pictorial review","volume":"59","author":"Cavka","year":"2023","journal-title":"Medicina (Mex.)"},{"key":"B20","first-page":"675","article-title":"Functional anatomy of the spine","volume-title":"Handbook of Clinical Neurology","author":"Bogduk","year":"2016"},{"key":"B21","doi-asserted-by":"publisher","first-page":"115555","DOI":"10.1016\/j.bone.2020.115555","article-title":"Region-dependent bone loss in the lumbar spine following femoral fracture in mice","volume":"140","author":"Ely","year":"2020","journal-title":"Bone"},{"key":"B22","doi-asserted-by":"publisher","first-page":"CD006349","DOI":"10.1002\/14651858.CD006349.pub3","article-title":"Percutaneous vertebroplasty for osteoporotic vertebral compression fracture","volume":"4","author":"Buchbinder","year":"2018","journal-title":"Cochrane Database Syst Rev"},{"key":"B23","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.jot.2016.09.002","article-title":"Bone cement allocation analysis in artificial cancellous bone structures","volume":"8","author":"Zderic","year":"2017","journal-title":"J Orthop Transl"},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.2696","article-title":"Multiphasic modelling of bone-cement injection into vertebral cancellous bone","volume":"31","author":"Bleiler","year":"2015","journal-title":"Int J Numer Methods Biomed Eng"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/160237","article-title":"Computer simulation and analysis on flow characteristics and distribution patterns of polymethylmethacrylate in lumbar vertebral body and vertebral pedicle","volume":"2015","author":"Liu","year":"2015","journal-title":"BioMed Res Int"},{"key":"B26","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/S0021-9290(03)00246-X","article-title":"Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration","volume":"37","author":"Baroud","year":"2004","journal-title":"J Biomech"},{"key":"B27","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.1097\/BRS.0b013e3181732aa9","article-title":"Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate","volume":"33","author":"Loeffel","year":"2008","journal-title":"Spine"},{"key":"B28","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.actbio.2018.03.014","article-title":"In vivo response to a low-modulus PMMA bone cement in an ovine model","volume":"72","author":"Robo","year":"2018","journal-title":"Acta Biomater"},{"key":"B29","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.jmbbm.2018.03.016","article-title":"In vitro biocompatibility, bioactivity, and mechanical strength of PMMA-PCL polymer containing fluorapatite and graphene oxide bone cements","volume":"82","author":"Pahlevanzadeh","year":"2018","journal-title":"J Mech Behav Biomed Mater"},{"key":"B30","doi-asserted-by":"publisher","first-page":"789","DOI":"10.3171\/2010.12.SPINE10453","article-title":"A method to develop an in vitro osteoporosis model of porcine vertebrae: histological and biomechanical study: laboratory investigation","volume":"14","author":"Lee","year":"2011","journal-title":"J Neurosurg Spine"},{"key":"B31","doi-asserted-by":"publisher","first-page":"2562","DOI":"10.1097\/01.brs.0000240695.58651.62","article-title":"High-Viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage","volume":"31","author":"Baroud","year":"2006","journal-title":"Spine"},{"key":"B32","doi-asserted-by":"publisher","first-page":"e2023153","DOI":"10.23750\/abm.v94i3.14487","article-title":"Outcomes at 2 years follow-up of sacral fractures associated with unstable vertical pelvic ring injuries in obese patients: a multicentric retrospective study: sacral fractures and pelvic injuries in obese patients","volume":"94","author":"Liuzza","year":"2023","journal-title":"Acta Biomed Atenei Parm"},{"key":"B33","doi-asserted-by":"publisher","first-page":"3411","DOI":"10.1007\/s00586-015-3923-0","article-title":"Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures","volume":"25","author":"Ding","year":"2016","journal-title":"Eur Spine J"},{"key":"B34","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1186\/s12891-021-04823-3","article-title":"The role of femoral obliquity angle and T1 pelvic angle in predicting quality of life after spinal surgery in adult spinal deformities","volume":"22","author":"Perna","year":"2021","journal-title":"BMC Musculoskelet Disord"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2024.1444817\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T05:10:29Z","timestamp":1729746629000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2024.1444817\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,24]]},"references-count":34,"alternative-id":["10.3389\/fsurg.2024.1444817"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2024.1444817","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,24]]},"article-number":"1444817"}}