{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T16:46:12Z","timestamp":1764002772176,"version":"3.41.2"},"reference-count":12,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T00:00:00Z","timestamp":1736208000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:p>We report a case of a patient with dilated cardiomyopathy who experienced recurrent ventricular tachycardia (VT) and multiple defibrillations following CRT-D implantation. Due to worsening cardiac function, the patient required surgical implantation of a left ventricular assist device (LVAD) as a bridge to heart transplantation. During the procedure, we used the Ensite three-dimensional mapping system to perform activation and substrate mapping of the VT targets, followed by endocardial and epicardial cryoballoon ablation of clinical VT. Subsequently, during LVAD implantation, dual cryoballoon ablation was applied around the surgical incision site to prevent VT associated with the surgical wound and the implanted device. At the 1-year follow-up, the patient had no recurrence of the original clinical VT and no new ventricular arrhythmias were observed.<\/jats:p>","DOI":"10.3389\/fsurg.2024.1449007","type":"journal-article","created":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T06:43:47Z","timestamp":1736232227000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Case Report: Left ventricular assist device implantation combined with cryoballoon ablation for ventricular tachycardia"],"prefix":"10.3389","volume":"11","author":[{"given":"Shuang","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianming","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changming","family":"Tan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingxian","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hanze","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liyi","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuping","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2025,1,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1016\/j.ahj.2012.06.018","article-title":"Epidemiology, management, and outcomes of sustained ventricular arrhythmias after continuous-flow left ventricular assist device implantation","volume":"164","author":"Raasch","year":"2012","journal-title":"Am Heart J"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1016\/j.healun.2015.05.018","article-title":"Early post-operative ventricular arrhythmias in patients with continuous-flow left ventricular assist devices","volume":"34","author":"Garan","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"B3","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1097\/mat.0000000000000349","article-title":"Arrhythmias in patients with cardiac implantable electrical devices after implantation of a left ventricular assist device","volume":"62","author":"Rosenbaum","year":"2016","journal-title":"Asaio J"},{"key":"B4","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1016\/j.jacep.2018.04.014","article-title":"Management of arrhythmias and cardiac implantable electronic devices in patients with left ventricular assist devices","volume":"4","author":"Ho","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"B5","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1093\/eurjhf\/hfs062","article-title":"Use of implantable cardioverter defibrillators in patients with left ventricular assist devices","volume":"14","author":"Pettit","year":"2012","journal-title":"Eur J Heart Fail"},{"key":"B6","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1111\/j.1540-8167.2011.02223.x","article-title":"Risk of mortality for ventricular arrhythmia in ambulatory LVAD patients","volume":"23","author":"Brenyo","year":"","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B7","doi-asserted-by":"publisher","first-page":"2542","DOI":"10.1016\/j.jacc.2013.04.020","article-title":"Ventricular arrhythmias and implantable cardioverter-defibrillator therapy in patients with continuous-flow left ventricular assist devices: need for primary prevention?","volume":"61","author":"Garan","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1016\/j.cardfail.2014.12.006","article-title":"Impact of cardiac resynchronization therapy on clinical outcomes in patients with continuous-flow left ventricular assist devices","volume":"21","author":"Gopinathannair","year":"2015","journal-title":"J Card Fail"},{"key":"B9","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1161\/circep.114.002394","article-title":"Characteristics of ventricular tachycardia ablation in patients with continuous flow left ventricular assist devices","volume":"8","author":"Sacher","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.3390\/s24041124","article-title":"Ventricular arrhythmias in left ventricular assist device patients-current diagnostic and therapeutic considerations","volume":"24","author":"Za\u0142ucka","year":"2024","journal-title":"Sensors (Basel)"},{"key":"B11","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.hrthm.2012.01.018","article-title":"Electrophysiologic characteristics and catheter ablation of ventricular tachyarrhythmias among patients with heart failure on ventricular assist device support","volume":"9","author":"Cantillon","year":"2012","journal-title":"Heart Rhythm"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1016\/j.jtcvs.2012.03.061","article-title":"Cryoablation during left ventricular assist device implantation reduces postoperative ventricular tachyarrhythmias","volume":"145","author":"Mulloy","year":"2013","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2024.1449007\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T06:43:51Z","timestamp":1736232231000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2024.1449007\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,7]]},"references-count":12,"alternative-id":["10.3389\/fsurg.2024.1449007"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2024.1449007","relation":{},"ISSN":["2296-875X"],"issn-type":[{"type":"electronic","value":"2296-875X"}],"subject":[],"published":{"date-parts":[[2025,1,7]]},"article-number":"1449007"}}