{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T04:23:08Z","timestamp":1784175788014,"version":"3.55.0"},"reference-count":19,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T00:00:00Z","timestamp":1748304000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To investigate the clinical efficacy of electromyography (EMG) in unilateral biportal endoscopy (UBE) with general anesthesia in the treatment of lumbar disc herniation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A total of 78 patients with lumbar disc herniation were enrolled. They underwent UBE discectomy under general anesthesia, with the entire procedure of EMG monitoring. Recorded potentials were displayed on the monitoring screen, and electromyographic activity was audibly relayed via speakers. Clinical treatment outcomes were assessed using Visual Analog Scale (VAS) and Oswestry Disability Index (ODI).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>All 78 patients successfully completed the procedure, with significant improvement in symptoms postoperatively. Preoperative and 3-month postoperative VAS scores were 4\u20139 (mean 6.65\u2009\u00b1\u20091.53) and 0\u20134 (mean 1.40\u2009\u00b1\u20091.23), respectively. Preoperative and 3-month postoperative ODI scores were 36\u201388 (mean 59.56\u2009\u00b1\u200913.81) and 4\u201329 (mean 14.82\u2009\u00b1\u20096.68), respectively, with statistically significant differences (<jats:italic>P<\/jats:italic>\u2009&amp;lt;\u20090.05). Abnormal EMG changes, including spike, burst, or tonic electromyographic discharges, occurred in 12 patients during surgery, with an incidence of 15.38%. Ten patients experienced radicular burning pain and abnormal lower limb sensations postoperatively, while two patients had no significant postoperative neuralgia, resulting in a false positive rate of 16.67%. Patients without abnormal EMG responses during surgery had no significant postoperative neuralgia, yielding a false negative rate of zero.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>General anesthesia combined with UBE monitord by intraoperative EMG is a safe and feasible approach for the treatment of lumbar disc herniation.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fsurg.2025.1498878","type":"journal-article","created":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T04:11:08Z","timestamp":1748319068000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["The preliminary application of electromyography in unilateral biportal endoscopy with general anesthesia for lumbar disc herniation"],"prefix":"10.3389","volume":"12","author":[{"given":"Shaolong","family":"Tang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yutian","family":"Liao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dayong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,5,27]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1055\/s-0036-1592157","article-title":"Biportal endoscopic lumbar decompression for lumbar disk herniation and spinal canal stenosis: a technical note","volume":"78","author":"Eun","year":"2017","journal-title":"J Neurol Surg A Cent Eur Neurosurg"},{"key":"B2","doi-asserted-by":"publisher","first-page":"437","DOI":"10.3390\/medicina59030437","article-title":"Comparison of outcomes between unilateral biportal endoscopic and percutaneous posterior endoscopic cervical keyhole surgeries","volume":"59","author":"Wang","year":"2023","journal-title":"Medicina (Kaunas)"},{"key":"B3","doi-asserted-by":"publisher","first-page":"79","DOI":"10.31616\/asj.2019.0025","article-title":"Clinical significance of improved intraoperative neurophysiological monitoring signal during spine surgery: a retrospective study of a single-institution prospective cohort","volume":"14","author":"Wi","year":"2020","journal-title":"Asian Spine J"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1177\/21925682231219224","article-title":"Transcranial motor evoked potentials as a predictive modality for postoperative deficit in cervical spine decompression surgery - A systematic review and meta-analysis","volume":"14","author":"Reddy","year":"2024","journal-title":"Global Spine J"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1298","DOI":"10.1111\/os.13724","article-title":"Intra-operative neurophysiological monitoring in patients with thoracic spinal stenosis: its feasibility and high-risk factors for new neurological deficit","volume":"15","author":"Liu","year":"2023","journal-title":"Orthop Surg"},{"key":"B6","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.3171\/2017.5","article-title":"Fully endoscopic lumbar interbody fusion using a percutaneous unilateral biportal endoscopic technique: technical note and preliminary clinical results","volume":"43","author":"Heo","year":"2017","journal-title":"Neurosurg Focus"},{"key":"B7","doi-asserted-by":"publisher","first-page":"602","DOI":"10.3171\/2015.7","article-title":"Percutaneous biportalendoscopic decompression for lumbar spinal stenosis: a technical note and preliminary clinical results","volume":"24","author":"Euni","year":"2016","journal-title":"J Neurosurg Spine"},{"key":"B8","doi-asserted-by":"publisher","first-page":"335","DOI":"10.4184\/asj.2016.10.2.335","article-title":"Two portal percutaneous endoscopic decompression for lumbar spinal stenosis: preliminary study","volume":"10","author":"Torudom","year":"2016","journal-title":"Asian Spine J"},{"key":"B9","doi-asserted-by":"publisher","first-page":"2075","DOI":"10.1016\/j.clinph.2018.07.005","article-title":"A new criterion for detection of radiculopathy based on motor evoked potentials and intraoperative nerve root monitoring","volume":"129","author":"Traba","year":"2018","journal-title":"Clin Neurophysiol"},{"key":"B10","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1097\/ACO.0000000000001044","article-title":"Anesthesia and intraoperative neurophysiological spinal cord monitoring","volume":"34","author":"Sahinovic","year":"2021","journal-title":"Curr Opin Anaesthesiol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/978-3-031-36084-8_9","article-title":"Methods and principles of the intraoperative neurophysiologic monitoring in neurosurgery","volume":"135","author":"Di Domenico","year":"2023","journal-title":"Acta Neurochir Suppl"},{"key":"B12","doi-asserted-by":"crossref","first-page":"167","DOI":"10.21037\/jss.2016.09.09","article-title":"Can intraoperative neurophysiologic monitoring during cervical spinede compression predict post-operative segmental C5 palsy","volume":"2","author":"Haghighi","year":"2016","journal-title":"J Spine Surg"},{"key":"B13","volume-title":"Spinal Cord Compression. in: StatPearls","author":"Singleton","year":"2025"},{"key":"B14","doi-asserted-by":"crossref","first-page":"100236","DOI":"10.1016\/j.bjao.2023.100236","article-title":"Validation of a convolutional neural network that reliably identifies electromyographic compound motor action potentials following train-of-four stimulation: an algorithm development experimental study","volume":"8","author":"Epstein","year":"2023","journal-title":"BJA Open"},{"key":"B15","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/B978-0-12-819826-1.00020-X","article-title":"Monitoring surgery around the cranial nerves","volume":"186","author":"L\u00f3pez","year":"2022","journal-title":"Handb Clin Neurol"},{"key":"B16","doi-asserted-by":"crossref","first-page":"379","DOI":"10.3171\/2016.2.JNS151384","article-title":"Analysis of facial motor evoked potentials for assessing a central mechanism in hemifacial spasm","volume":"126","author":"Wilkinson","year":"2017","journal-title":"J Neurosurg"},{"key":"B17","doi-asserted-by":"crossref","first-page":"1920","DOI":"10.1016\/j.spinee.2023.08.002","article-title":"Utility of intraoperative neurophysiological monitoring in detecting motor and sensory nerve injuries in pediatric high-grade spondylolisthesis","volume":"23","author":"Iorio","year":"2023","journal-title":"Spine J"},{"key":"B18","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1177\/0194599820912030","article-title":"Influence of sevoflurane-based anesthesia versus total intravenous anesthesia on intraoperative neuromonitoring during thyroidectomy","volume":"162","author":"Li","year":"2020","journal-title":"Otolaryngol Head Neck Surg"},{"key":"B19","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1097\/WNP.0000000000000111","article-title":"Train-of-four test in intraoperative neurophysiologic monitoring: differences between hand and foot train-of-four","volume":"31","author":"Gavrancic","year":"2014","journal-title":"J Clin Neurophysiol"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2025.1498878\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T04:11:10Z","timestamp":1748319070000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2025.1498878\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,27]]},"references-count":19,"alternative-id":["10.3389\/fsurg.2025.1498878"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2025.1498878","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,27]]},"article-number":"1498878"}}