{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T06:36:08Z","timestamp":1777358168471,"version":"3.51.4"},"reference-count":22,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:00:00Z","timestamp":1777334400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To overcome the surface marker drift issue in semi-rigid pelvic structures and establish a foundation for the binocular vision navigation targeting semi-rigid anatomical structures within the human body.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The study was conducted at Chongqing health center for women and children form April to June 2024. Surface markers were placed on 20 volunteers with semi-rigid pelvic anatomy. Respiratory and movement-induced displacement data were collected pre- and post-activity. A hybrid approach integrating a loss function and respiratory compensation algorithm was developed for spatial registration correction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>After correction through spatial registration using a mathematical model, the drift range of semi-rigid body surface markers was 0.86\u2009\u00b1\u20090.11\u2005mm. Specifically, the body surface drift ranges for the left anterior superior iliac spine marker were 0.79\u2009\u00b1\u20090.12\u2005mm, for the right anterior superior iliac spine marker were 0.85\u2009\u00b1\u20090.14\u2005mm, and for the pubic symphysis marker were 0.96\u2009\u00b1\u20090.25\u2005mm. The stability around the umbilicus was relatively poor, with an error range of 1.71\u2009\u00b1\u20090.91\u2005mm. Among the four markers, three have achieved positioning accuracy meeting the millimeter-level requirements for spatial registration in the current field of medical navigation surgery. The performance complies with the mandated sub-4-millimeter Target Registration Error (TRE) for optical tracking devices in surgical navigation applications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The first successful mitigation of surface marker drift issues by a mathematical compensation algorithm enabling binocular vision navigation in pelvic floor surgerys, and lays a foundation for future semi-rigid anatomical structure navigations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fsurg.2026.1735378","type":"journal-article","created":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T05:39:13Z","timestamp":1777354753000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Pioneering semi-rigid stability: navigating the female pelvis for enhanced precision in binocular vision guidance"],"prefix":"10.3389","volume":"13","author":[{"given":"Tieyuan","family":"Sun","sequence":"first","affiliation":[{"name":"Department of Obstetrics and Gynecology, Chongqing Health Center for Women and Children","place":["Chongqing, China"]},{"name":"Department of Obstetrics and Gynecology, Women and Children's Hospital of Chongqing Medical University","place":["Chongqing, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linna","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Chongqing Health Center for Women and Children","place":["Chongqing, China"]},{"name":"Department of Obstetrics and Gynecology, Women and Children's Hospital of Chongqing Medical University","place":["Chongqing, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pan","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Chongqing Health Center for Women and Children","place":["Chongqing, China"]},{"name":"Department of Obstetrics and Gynecology, Women and Children's Hospital of Chongqing Medical University","place":["Chongqing, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaolong","family":"You","sequence":"additional","affiliation":[{"name":"Department of Technology Development, Physoft Optical Research Group","place":["Chongqing, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lubin","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Chongqing Health Center for Women and Children","place":["Chongqing, China"]},{"name":"Department of Obstetrics and Gynecology, Women and Children's Hospital of Chongqing Medical University","place":["Chongqing, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingbo","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Chongqing Health Center for Women and Children","place":["Chongqing, China"]},{"name":"Department of Obstetrics and Gynecology, Women and Children's Hospital of Chongqing Medical University","place":["Chongqing, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,4,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1607","DOI":"10.1007\/s11548-017-1536-2","article-title":"3D Ultrasound registration-based visual servoing for neurosurgical navigation","volume":"12","author":"Zettinig","year":"2017","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"B2","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3969\/j.issn.1671-7104.2023.01.004","article-title":"[Research on the application of electromagnetic navigation technology in surgical robots]","volume":"47","author":"Shi","year":"2023","journal-title":"Zhongguo Yi Liao Qi Xie Za Zhi"},{"key":"B3","doi-asserted-by":"publisher","first-page":"10.1088\/1741-2552\/abc743","DOI":"10.1088\/1741-2552\/abc743","article-title":"A compact stereotactic system for image-guided surgical intervention","volume":"17","author":"Rusheen","year":"2020","journal-title":"J Neural Eng"},{"key":"B4","doi-asserted-by":"publisher","first-page":"27","DOI":"10.3969\/j.issn.1671-7104.2018.01.007","article-title":"[Automatic robotic puncture system for accurate liver cancer ablation based on optical surgical navigation]","volume":"42","author":"Hou","year":"2018","journal-title":"Zhongguo Yi Liao Qi Xie Za Zhi"},{"key":"B5","doi-asserted-by":"publisher","first-page":"066003","DOI":"10.1088\/1741-2552\/aadb49","article-title":"A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model","volume":"15","author":"Edwards","year":"2018","journal-title":"J Neural Eng"},{"key":"B6","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s00464-014-3655-y","article-title":"Stereotactic navigation for TAMIS-TME: opening the gateway to frameless, image-guided abdominal and pelvic surgery","volume":"29","author":"Atallah","year":"2015","journal-title":"Surg Endosc"},{"key":"B7","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s00345-024-04870-0","article-title":"Feasibility of stereotactic optical navigation for needle positioning in percutaneous nephrolithotomy","volume":"42","author":"Spenkelink","year":"2024","journal-title":"World J Urol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1007\/s10151-015-1329-y","article-title":"Image-guided real-time navigation for transanal total mesorectal excision: a pilot study","volume":"19","author":"Atallah","year":"2015","journal-title":"Tech Coloproctol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1007\/s11701-022-01504-8","article-title":"A comparison between robot-guided and stereotactic frame-based stereoelectroencephalography (SEEG) electrode implantation for drug-resistant epilepsy","volume":"17","author":"Yao","year":"2023","journal-title":"J Robot Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s00264-009-0903-1","article-title":"Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand","volume":"35","author":"Manzotti","year":"2011","journal-title":"Int Orthop"},{"key":"B11","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.coms.2019.06.001","article-title":"Surgical Navigation for Oral and Maxillofacial Surgery","volume":"31","author":"Demian","year":"2019","journal-title":".Oral Maxillofac Surg Clin North Am"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1007\/s11548-017-1629-y","article-title":"Translatory hip kinematics measured with optoelectronic surgical navigation","volume":"12","author":"Zakani","year":"2017","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"B13","doi-asserted-by":"publisher","first-page":"167","DOI":"10.3988\/jcn.2010.6.4.167","article-title":"Deep brain stimulation: technology at the cutting edge","volume":"6","author":"Shah","year":"2010","journal-title":"J Clin Neurol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1180907","DOI":"10.3389\/fpubh.2023.1180907","article-title":"Influence of pelvic floor disorders on quality of life in women","volume":"11","author":"Peinado Molina","year":"2023","journal-title":"Front Public Health"},{"key":"B15","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1007\/s10151-022-02643-8","article-title":"Stereotactic navigation using registration based on intra-abdominal landmarks in robotic-assisted lateral pelvic lymph node dissection","volume":"26","author":"Ochiai","year":"2022","journal-title":"Tech Coloproctol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/s13534-024-00434-8","article-title":"Expansion of stereotactic work envelope using transformation matrices and geometric algebra for neurosurgery","volume":"15","author":"Sharaf","year":"2025","journal-title":"Biomed Eng Lett"},{"key":"B17","doi-asserted-by":"publisher","first-page":"2713","DOI":"10.1007\/s00464-017-5968-0","article-title":"Advances in stereotactic navigation for pelvic surgery","volume":"32","author":"Wijsmuller","year":"2018","journal-title":"Surg Endosc"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1007\/s11548-019-02035-8","article-title":"Co-localized augmented human and x-ray observers in collaborative surgical ecosystem","volume":"14","author":"Fotouhi","year":"2019","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"B19","doi-asserted-by":"publisher","first-page":"e422","DOI":"10.1016\/j.wneu.2018.06.208","article-title":"Clinical feasibility of a wearable mixed-reality device in neurosurgery","volume":"118","author":"Incekara","year":"2018","journal-title":"World Neurosurg"},{"key":"B20","doi-asserted-by":"publisher","first-page":"e1137","DOI":"10.1097\/mao.0000000000001995","article-title":"Development of a mixed reality platform for lateral skull base anatomy","volume":"39","author":"McJunkin","year":"2018","journal-title":"Otol Neurotol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/2193-1801-2-90","article-title":"Technical accuracy of optical and the electromagnetic tracking systems","volume":"2","author":"Koivukangas","year":"2013","journal-title":"Springerplus"},{"key":"B22","doi-asserted-by":"publisher","first-page":"676","DOI":"10.7518\/hxkq.2022.06.008","article-title":"Application of mixed reality-based surgical navigation system in craniomaxillofacial trauma bone reconstruction","volume":"40","author":"Lin","year":"2022","journal-title":"Hua Xi Kou Qiang Yi Xue Za Zhi"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1735378\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T05:39:15Z","timestamp":1777354755000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1735378\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,28]]},"references-count":22,"alternative-id":["10.3389\/fsurg.2026.1735378"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2026.1735378","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,28]]},"article-number":"1735378"}}