{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T05:38:17Z","timestamp":1793165897239,"version":"4.5.0"},"reference-count":29,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The aim of this study was to investigate the safety and feasibility of 3D-printed puncture guides assisting in unilateral-approach percutaneous vertebroplasty (PVP) for the treatment of osteoporotic vertebral compression fractures (OVCFs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We retrospectively analyzed the medical records of 106 patients admitted to the Department of Spine Surgery of the Affiliated Hospital of Yan'an University who underwent PVP with a unilateral approach from June 2020 to June 2022, and divided them into 2 groups based on the use of 3D-printed perforation guides during the operation: 52 patients in the 3D-printed perforation guide-assisted PVP group (Observation group), and 54 patients in the traditional PVP group (Control group). The general information, operation time, puncture time, number of intraoperative C-arm fluoroscopies, amount of bone cement injected, postoperative complications, pedicle wall breaches by the puncture needle trajectory, and the degree of compression of the anterior margin of the vertebral body and the Cobb's angle, which were measured on the lateral views of the injured vertebrae preoperatively and postoperatively, were recorded and compared between the two groups. A visual analogue scale (VAS) was used to evaluate the degree of pain in the injured vertebral region, and the Oswestry Disability Index (ODI) was used to assess the degree of functional disability of the patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      (1) There were no statistically significant differences between the two groups regarding gender, age, body mass index (BMI), bone mineral density (BMD), injured segment, and other baseline characteristics (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;gt;\u20090.05). (2) The operation time, intraoperative puncture time, and cement leakage rate in the observation group were lower than those in the control group (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05). Furthermore, the incidence of nerve root injury, whole-cement displacement, contralateral diffusion, and puncture paths breaching the pedicle walls was significantly lower in the observation group compared to the control group (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05). (3) The degree of vertebral anterior compression in the observation group at 1 day postoperatively [(21.01\u2009\u00b1\u20091.98)%] was significantly lower than that in the control group [(23.21\u2009\u00b1\u20092.47)%] (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05). (4) There were no statistically significant differences in the amount of bone cement injected or the incidence of adjacent vertebral fractures between the two groups (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;gt;\u20090.05). (5) There was no statistically significant difference in the comparison of the VAS scores and ODI scores of the two groups in the postoperative period and during the postoperative follow-up period (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;gt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>3D-printed puncture guide-assisted unilateral approach PVP for the treatment of single-segment OVCFs has significant clinical advantages compared with the traditional unarmed puncture group. Specifically, it improves the ratio of overall to contralateral bone cement dispersion volume, significantly enhances puncture accuracy, and reduces the incidence of surgical complications. It also reduces the number of fluoroscopies, shortens the operative time, and comprehensively improves surgical safety and operational efficiency.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fsurg.2026.1800908","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T04:59:39Z","timestamp":1779944379000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Enhancing precision in percutaneous vertebroplasty: a study on patient-specific 3D-printed guides for osteoporotic vertebral compression fractures"],"prefix":"10.3389","volume":"13","author":[{"given":"Jia-Wen","family":"Liang","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Affiliated Hospital of Yan'an University","place":["Yan'an, Shaanxi Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Na","family":"Qiao","sequence":"additional","affiliation":[{"name":"Department of Pathology, Affiliated Hospital of Yan'an University","place":["Yan'an, Shaanxi Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying-Ao","family":"Jia","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Affiliated Hospital of Yan'an University","place":["Yan'an, Shaanxi Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liang","family":"Xue","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Affiliated Hospital of Yan'an University","place":["Yan'an, Shaanxi Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Yang","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Affiliated Hospital of Yan'an University","place":["Yan'an, Shaanxi Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Affiliated Hospital of Yan'an University","place":["Yan'an, Shaanxi Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1007\/s00586-018-5605-1","article-title":"Osteoporotic thoracolumbar compression fractures: long-term retrospective comparison between vertebroplasty and conservative treatment","volume":"27","author":"Martikos","year":"2018","journal-title":"Eur Spine J"},{"key":"B2","first-page":"E113","article-title":"Treatment of osteoporotic vertebral compression fractures: applicability of appropriateness criteria in clinical practice","volume":"19","author":"Schupfner","year":"2016","journal-title":"Pain Physician"},{"key":"B3","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.injury.2017.11.008","article-title":"Surgical options for osteoporotic vertebral compression fractures complicated with spinal deformity and neurologic deficit","volume":"49","author":"Alpantaki","year":"2018","journal-title":"Injury"},{"key":"B4","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1097\/00007632-200101150-00008","article-title":"An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture","volume":"26","author":"Belkoff","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.2147\/CIA.S54613","article-title":"Epidemiology and management of osteoporosis in the people\u2019s republic of China: current perspectives","volume":"10","author":"Lin","year":"2015","journal-title":"Clin Interv Aging"},{"key":"B6","doi-asserted-by":"publisher","first-page":"3947368","DOI":"10.1155\/2020\/3947368","article-title":"Advances in vertebral augmentation systems for osteoporotic vertebral compression fractures","volume":"2020","author":"Long","year":"2020","journal-title":"Pain Res Manag"},{"key":"B7","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1007\/s00264-022-05654-0","article-title":"Robot-assisted percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a retrospective matched-cohort study","volume":"47","author":"Tan","year":"2023","journal-title":"Int Orthop"},{"key":"B8","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1186\/s13018-021-02471-w","article-title":"A novel \u201cthree-dimensional-printed individual guide template-assisted percutaneous vertebroplasty\u201d for osteoporotic vertebral compression fracture: a prospective, controlled study","volume":"16","author":"Hu","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"B9","doi-asserted-by":"publisher","first-page":"250","DOI":"10.5137\/1019-5149.JTN.43052-22.2","article-title":"Evaluation of percutaneous unilateral kyphoplasty results in osteoporotic vertebral compression fractures using individual 3D printed guide template support","volume":"34","author":"Cingoz","year":"2024","journal-title":"Turk Neurosurg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"e20770","DOI":"10.1097\/MD.0000000000020770","article-title":"Therapeutic effect of percutaneous vertebroplasty and nonoperative treatment on osteoporotic vertebral compression fracture: a randomized controlled trial protocol","volume":"99","author":"Wang","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"B11","doi-asserted-by":"publisher","first-page":"E143","DOI":"10.36076\/ppj.2023.26.E143","article-title":"Efficacy and safety of a 3D-printed guide device during percutaneous kyphoplasty for the treatment of osteoporotic vertebral compression fractures","volume":"26","author":"Wang","year":"2023","journal-title":"Pain Physician"},{"key":"B12","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.amjmed.2022.02.035","article-title":"Diagnosis and management of vertebral compression fracture","volume":"135","author":"Alsoof","year":"2022","journal-title":"Am J Med"},{"key":"B13","first-page":"555","article-title":"Percutaneous vertebroplasty compared with optimal pain medication treatment: short-term clinical outcome of patients with subacute or chronic painful osteoporotic vertebral compression fractures. The VERTOS study","volume":"28","author":"Voormolen","year":"2007","journal-title":"AJNR Am J Neuroradiol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/s13018-016-0479-6","article-title":"Comparison of unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a systematic review and meta-analysis","volume":"11","author":"Sun","year":"2016","journal-title":"J Orthop Surg Res"},{"key":"B15","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1186\/s12891-023-06997-4","article-title":"Effect of different cement distribution in bilateral and unilateral percutaneous vertebro plasty on the clinical efficacy of vertebral compression fractures","volume":"24","author":"Haibier","year":"2023","journal-title":"BMC Musculoskelet Disord"},{"key":"B16","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1007\/s00590-025-04241-4","article-title":"Comparison of near- and midterm outcomes of two unilateral percutaneous translaminar vertebral kyphoplasty procedures for the treatment of single-segment OVCF: a single-center randomized controlled study","volume":"35","author":"Fuguo","year":"2025","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2147\/CIA.S438036","article-title":"Percutaneous curved vertebroplasty decrease the risk of cemented vertebra refracture compared with bilateral percutaneous kyphoplasty in the treatment of osteoporotic vertebral compression fractures","volume":"19","author":"Zhou","year":"2024","journal-title":"Clin Interv Aging"},{"key":"B18","doi-asserted-by":"publisher","first-page":"e0276930","DOI":"10.1371\/journal.pone.0276930","article-title":"Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures","volume":"17","author":"Chen","year":"2022","journal-title":"PLoS One"},{"key":"B19","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.jocn.2018.03.012","article-title":"3-dimensional printing guide template assisted percutaneous vertebroplasty: technical note","volume":"52","author":"Li","year":"2018","journal-title":"J Clin Neurosci"},{"key":"B20","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1177\/1553350619853134","article-title":"\u201cTargeted percutaneous vertebroplasty\u201d versus traditional percutaneous vertebroplasty for osteoporotic vertebral compression fracture","volume":"26","author":"Xu","year":"2019","journal-title":"Surg Innov"},{"key":"B21","first-page":"E33","article-title":"Risk factors for the occurrence of insufficient cement distribution in the fractured area after percutaneous vertebroplasty in osteoporotic vertebral compression fractures","volume":"21","author":"Ye","year":"2018","journal-title":"Pain Physician"},{"key":"B22","doi-asserted-by":"publisher","first-page":"5271","DOI":"10.12659\/msm.907364","article-title":"Risk factors associated with adjacent vertebral compression fracture following percutaneous vertebroplasty after menopause: a retrospective study","volume":"23","author":"Li","year":"2017","journal-title":"Med Sci Monit"},{"key":"B23","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1186\/s13018-025-05868-z","article-title":"Bone cement distribution patterns in vertebral augmentation for osteoporotic vertebral compression fractures: a systematic review","volume":"20","author":"Yang","year":"2025","journal-title":"J Orthop Surg Res"},{"key":"B24","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1186\/s12891-020-03568-9","article-title":"The effect of bone cement distribution on the outcome of percutaneous vertebroplasty: a case cohort study","volume":"21","author":"Tan","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"B25","doi-asserted-by":"publisher","first-page":"978917","DOI":"10.3389\/fbioe.2022.978917","article-title":"Biomechanical comparison between unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a finite element analysis","volume":"10","author":"Dai","year":"2022","journal-title":"Front Bioeng Biotechnol"},{"key":"B26","doi-asserted-by":"publisher","first-page":"2778","DOI":"10.12998\/wjcc.v9.i12.2778","article-title":"Predictive risk factors for recollapse of cemented vertebrae after percutaneous vertebroplasty: a meta-analysis","volume":"9","author":"Ma","year":"2021","journal-title":"World J Clin Cases"},{"key":"B27","doi-asserted-by":"publisher","first-page":"732","DOI":"10.12200\/j.issn.1003-0034.2021.08.008","article-title":"Biomechanical effects of different bone cement diffusion patterns after vertebroplasty: finite element analysis","volume":"34","author":"Yao","year":"2021","journal-title":"Zhongguo Gu Shang"},{"key":"B28","doi-asserted-by":"publisher","first-page":"4609","DOI":"10.12998\/wjcc.v12.i21.4609","article-title":"Factors influencing further vertebral height loss following percutaneous vertebroplasty in osteoporotic vertebral compression fractures: a 1-year follow-up study","volume":"12","author":"Tang","year":"2024","journal-title":"World J Clin Cases"},{"key":"B29","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1186\/s13018-022-03087-4","article-title":"Association between bone turnover markers, BMD and height loss of cemented vertebrae after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures","volume":"17","author":"Lin","year":"2022","journal-title":"J Orthop Surg Res"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1800908\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T04:59:49Z","timestamp":1779944389000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1800908\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":29,"alternative-id":["10.3389\/fsurg.2026.1800908"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2026.1800908","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"article-number":"1800908"}}