{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T06:41:57Z","timestamp":1776235317803,"version":"3.50.1"},"reference-count":42,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T00:00:00Z","timestamp":1776211200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Zero-P VA device is a unique zero-profile device comprising only two integrated variable-angle screws which may provide inferior mechanical stability compared with other types of devices. There is a lack of comprehensive clinical and radiological evidence comparing the plate-cage construct (PCC) and the Zero-P VA device in single-level anterior cervical discectomy and fusion (ACDF).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We retrospectively reviewed consecutive patients who underwent single-level ACDF using either the Zero-P VA device (50 cases) or the PCC (51 cases). Clinical outcomes were evaluated using the Visual Analogue Scale (VAS) and Japanese Orthopaedic Association (JOA) scores. Radiological outcomes were assessed using standard lateral cervical x-ray films. Data were recorded preoperatively, immediately postoperatively, and at 3- and 12-month follow-up visits.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      VAS and JOA scores, cervical alignment, segmental angle, and surgical segment height were all significantly improved postoperatively in both groups. However, in the Zero-P VA group, the segmental angle and anterior height of the surgical segment at 3 and 12 months decreased significantly compared with immediate postoperative values and were significantly lower than those observed in the PCC group. The rate of segmental kyphosis was significantly higher in the Zero-P VA group at the 12-month follow-up (12% vs. 0%,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05), while fusion rates were comparable.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The Zero-P VA device provides short-term clinical outcomes comparable to those of the PCC for single-level ACDF. However, it is associated with inferior radiological outcomes, specifically greater loss of segmental lordosis and anterior surgical segment height. The surgeon's choice of implant therefore involves a clinical trade-off between the established surgical advantages of a zero-profile system and the superior radiological stability offered by the PCC.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fsurg.2026.1800991","type":"journal-article","created":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T05:41:49Z","timestamp":1776231709000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Outcome evaluation of the zero-profile device comprising two integrated variable angle screws used for single-level cervical degenerative disc disease: comparison with the plate-cage construct"],"prefix":"10.3389","volume":"13","author":[{"given":"Can","family":"Cao","sequence":"first","affiliation":[{"name":"Department of Spinal Surgery, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]},{"name":"Department of Orthopedics, Hebei General Hospital","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yun-Sheng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"You-bin","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, The First Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xian-Da","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xing-Zhu","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qing-Tao","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin-Feng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, Hebei, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,4,15]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1055\/s-2008-1081201","article-title":"Treatment of cervical degenerative disc disease\u2014current status and trends","volume":"69","author":"Korinth","year":"2008","journal-title":"Zentralbl Neurochir"},{"key":"B2","doi-asserted-by":"publisher","first-page":"531","DOI":"10.4184\/asj.2014.8.4.531","article-title":"Current concepts of anterior cervical discectomy and fusion: a review of literature","volume":"8","author":"Song","year":"2014","journal-title":"Asian Spine J"},{"key":"B3","doi-asserted-by":"crossref","first-page":"607","DOI":"10.2106\/00004623-195840030-00009","article-title":"The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion","volume":"40","author":"Gw","year":"1958","journal-title":"J Bone Joint Surg Am"},{"key":"B4","doi-asserted-by":"publisher","first-page":"e484","DOI":"10.1016\/j.wneu.2022.07.033","article-title":"Comparison of the postoperative motion stabilization between anterior cervical decompression and fusion with a zero-profile implant system and a plate-cage construct","volume":"166","author":"Abudouaini","year":"2022","journal-title":"World Neurosurg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"2310","DOI":"10.1097\/BRS.0b013e318154c57e","article-title":"Anterior cervical discectomy and fusion associated complications","volume":"32","author":"Fountas","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"B6","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1097\/BRS.0b013e31818ff9c4","article-title":"A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices","volume":"34","author":"Scholz","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"B7","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1097\/01.bsd.0000177211.44960.71","article-title":"Influence of anterior cervical plate design on dysphagia: a 2-year prospective longitudinal follow-up study","volume":"18","author":"Lee","year":"2005","journal-title":"J Spinal Disord Tech"},{"key":"B8","doi-asserted-by":"publisher","first-page":"2734","DOI":"10.1007\/s00586-020-06561-x","article-title":"Locking stand-alone cage versus anterior plate construct in anterior cervical discectomy and fusion: a systematic review and meta-analysis based on randomized controlled trials","volume":"29","author":"Zhao","year":"2020","journal-title":"Eur Spine J"},{"key":"B9","doi-asserted-by":"publisher","first-page":"e300","DOI":"10.1016\/j.wneu.2019.11.153","article-title":"Can zero-profile cage maintain the cervical curvature similar to plate-cage construct for single-level anterior cervical diskectomy and fusion?","volume":"135","author":"Li","year":"2020","journal-title":"World Neurosurg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2258","DOI":"10.1007\/s00586-017-5015-9","article-title":"Locking stand-alone cages versus anterior plate constructs in single-level fusion for degenerative cervical disease: a systematic review and meta-analysis","volume":"26","author":"Nambiar","year":"2017","journal-title":"Eur Spine J"},{"key":"B11","doi-asserted-by":"publisher","first-page":"e551","DOI":"10.1016\/j.wneu.2018.08.128","article-title":"Zero-profile versus cage and plate in anterior cervical discectomy and fusion with a Minimum 2 years of follow-up: a meta-analysis","volume":"120","author":"Sun","year":"2018","journal-title":"World Neurosurg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1097\/BRS.0000000000003312","article-title":"Application of zero-profile spacer in the treatment of three-level cervical spondylotic myelopathy: 5-year follow-up results","volume":"45","author":"Sun","year":"2020","journal-title":"Spine (Phila Pa 1976)"},{"key":"B13","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1016\/j.wneu.2016.12.060","article-title":"A clinical comparison of anterior cervical plates versus stand-alone intervertebral fusion devices for single-level anterior cervical discectomy and fusion procedures","volume":"99","author":"Panchal","year":"2017","journal-title":"World Neurosurg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"219","DOI":"10.3171\/2020.11.SPINE201319","article-title":"Use of zero-profile device for contiguous three-level anterior cervical discectomy and fusion: comparison with cage and plate construct","volume":"35","author":"Chen","year":"2021","journal-title":"J Neurosurg Spine"},{"key":"B15","doi-asserted-by":"publisher","first-page":"215","DOI":"10.14444\/8206","article-title":"2-level anterior cervical arthrodesis with integrated spacer and plate vs. traditional anterior spacer and plate system","volume":"16","author":"Thind","year":"2022","journal-title":"Int J Spine Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/s12891-018-1950-9","article-title":"Comparison among perfect-C\u00ae, zero-P\u00ae, and plates with a cage in single-level cervical degenerative disc disease","volume":"19","author":"Noh","year":"2018","journal-title":"BMC Musculoskelet Disord"},{"key":"B17","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.wneu.2016.09.065","article-title":"Use of a zero-profile device for contiguous 2-level anterior cervical diskectomy and fusion: comparison with cage with plate construct","volume":"97","author":"Yun","year":"2017","journal-title":"World Neurosurg"},{"key":"B18","doi-asserted-by":"publisher","first-page":"e226","DOI":"10.1016\/j.wneu.2018.04.019","article-title":"Comparison of zero-profile device versus plate-and-cage implant in the treatment of symptomatic adjacent segment disease after anterior cervical discectomy and fusion: a Minimum 2-year follow-up study","volume":"115","author":"Shen","year":"2018","journal-title":"World Neurosurg"},{"key":"B19","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1007\/s00586-012-2446-1","article-title":"Biomechanical evaluation of a low profile, anchored cervical interbody spacer device in the setting of progressive flexion-distraction injury of the cervical spine","volume":"22","author":"Wojewnik","year":"2013","journal-title":"Eur Spine J"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1177\/21925682241232616","article-title":"Are patients with segmental cervical kyphosis appropriate candidates for cervical disc arthroplasty (CDA)? A clinical and radiographic analysis compared to anterior cervical discectomy and fusion (ACDF)","volume":"15","author":"Abdelmalek","year":"2025","journal-title":"Global Spine J"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1097\/01.BRS.0000065487.82469.D9","article-title":"Local kyphosis reduces surgical outcomes of expansive open-door laminoplasty for cervical spondylotic myelopathy","volume":"28","author":"Suda","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"B22","doi-asserted-by":"publisher","first-page":"E792","DOI":"10.1097\/BRS.0b013e3182913400","article-title":"Anterior interbody fusion of the cervical spine with zero-P spacer: prospective comparative study-clinical and radiological results at a minimum 2 years after surgery","volume":"38","author":"Vanek","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"B23","doi-asserted-by":"publisher","first-page":"2886","DOI":"10.1097\/BRS.0b013e3181b64f2c","article-title":"The efficacy of plate construct augmentation versus cage alone in anterior cervical fusion","volume":"34","author":"Song","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"B24","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/BRS.0000000000004465","article-title":"Comparing clinical and radiographic outcomes between the self-locking stand-alone cage and conventional cage-plate construct: a five-year retrospective cohort study","volume":"48","author":"Pan","year":"2023","journal-title":"Spine (Phila Pa 1976)"},{"key":"B25","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1186\/s40001-022-00813-w","article-title":"Clinical and radiological comparison of the zero-profile anchored cage and traditional cage-plate fixation in single-level anterior cervical discectomy and fusion","volume":"27","author":"Zhang","year":"2022","journal-title":"Eur J Med Res"},{"key":"B26","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s13018-022-02940-w","article-title":"Comparison of outcomes between zero-p implant and anterior cervical plate interbody fusion systems for anterior cervical decompression and fusion: a systematic review and meta-analysis of randomized controlled trials","volume":"17","author":"Zhang","year":"2022","journal-title":"J Orthop Surg Res"},{"key":"B27","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s13018-022-02917-9","article-title":"Application of a new integrated low-profile anterior plate and cage system in single-level cervical spondylosis: a preliminary retrospective study","volume":"17","author":"Wei","year":"2022","journal-title":"J Orthop Surg Res"},{"key":"B28","doi-asserted-by":"publisher","first-page":"899","DOI":"10.14444\/8115","article-title":"The impact of single-level anterior cervical discectomy and fusion on cervical sagittal parameters and its correlation with pain and functional outcome of patients with neck pain","volume":"15","author":"Rostami","year":"2021","journal-title":"Int J Spine Surg"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1227\/NEU.0b013e31820b51f3","article-title":"Prospective, randomized, double-blind clinical study evaluating the correlation of clinical outcomes and cervical sagittal alignment","volume":"68","author":"Villavicencio","year":"2011","journal-title":"Neurosurgery"},{"key":"B30","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1007\/s005860000243","article-title":"Kyphotic malalignment after anterior cervical fusion is one of the factors promoting the degenerative process in adjacent intervertebral levels","volume":"10","author":"Katsuura","year":"2001","journal-title":"Eur Spine J"},{"key":"B31","doi-asserted-by":"publisher","first-page":"E17","DOI":"10.1097\/BSD.0000000000000137","article-title":"Segmental kyphosis after cervical interbody fusion with stand-alone polyetheretherketone (PEEK) cages: a comparative study on 2 different PEEK cages","volume":"28","author":"Kim","year":"2015","journal-title":"J Spinal Disord Tech"},{"key":"B32","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1227\/NEU.0000000000000351","article-title":"Biomechanical assessment of anchored cervical interbody cages: comparison of 2-screw and 4-screw designs","volume":"10","author":"Reis","year":"2014","journal-title":"Neurosurgery"},{"key":"B33","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1016\/j.wneu.2017.06.051","article-title":"Multilevel anterior cervical diskectomy and fusion with zero-profile devices: analysis of safety and feasibility, with focus on sagittal alignment and impact on clinical outcome: single-institution experience and review of literature","volume":"106","author":"Albanese","year":"2017","journal-title":"World Neurosurg"},{"key":"B34","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1177\/2192568219834252","article-title":"A biomechanical evaluation of a next-generation integrated and modular ACDF device possessing full-plate, half-plate, and no-profile fixation iterations","volume":"9","author":"Panchal","year":"2019","journal-title":"Global Spine J"},{"key":"B35","doi-asserted-by":"publisher","first-page":"247","DOI":"10.14444\/8224","article-title":"Anterior cervical discectomy and fusion with a no-profile integrated fixation allograft device: an in vitro biomechanical analysis and clinical case series","volume":"16","author":"Salari","year":"2022","journal-title":"Int J Spine Surg"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1852","DOI":"10.1097\/BRS.0b013e31811ece5a","article-title":"Loss of cervical endplate integrity following minimal surface preparation","volume":"32","author":"Cheng","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"B37","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1177\/21925682211050325","article-title":"Computed tomography osteoabsorptiometry evaluation of cervical endplate subchondral bone mineral density","volume":"13","author":"Zavras","year":"2023","journal-title":"Global Spine J"},{"key":"B38","doi-asserted-by":"publisher","first-page":"S127","DOI":"10.1007\/s00590-014-1547-4","article-title":"Stand-alone anchored cage versus cage with plating for single-level anterior cervical discectomy and fusion: a prospective, randomized, controlled study with a 2-year follow-up","volume":"25","author":"Nemoto","year":"2015","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"B39","doi-asserted-by":"publisher","first-page":"123474","DOI":"10.1016\/j.wneu.2024.11.057","article-title":"Does bone preservation at the anterior edge of the vertebral body affect the subsidence of zero-profile cages after anterior cervical discectomy and fusion?","volume":"194","author":"Zhang","year":"2024","journal-title":"World Neurosurg"},{"key":"B40","doi-asserted-by":"publisher","first-page":"2641","DOI":"10.1097\/CM9.0000000000001129","article-title":"Space between the titanium plate of zero-profile cage and endplate of the vertebral body might affect the fusion process in anterior cervical discectomy and fusion","volume":"133","author":"Deng","year":"2020","journal-title":"Chin Med J (Engl"},{"key":"B41","doi-asserted-by":"publisher","first-page":"264","DOI":"10.4184\/asj.2017.11.2.264","article-title":"A prospective study of clinical and radiological outcomes of zero-profile cage screw implants for single-level anterior cervical discectomy and fusion: is segmental lordosis maintained at 2 years?","volume":"11","author":"Basu","year":"2017","journal-title":"Asian Spine J"},{"key":"B42","doi-asserted-by":"publisher","first-page":"2355","DOI":"10.1111\/os.14139","article-title":"Does screw number of zero-profile implants in fusion segment influence intervertebral stability?","volume":"16","author":"Peng","year":"2024","journal-title":"Orthop Surg"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1800991\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T05:41:50Z","timestamp":1776231710000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1800991\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,15]]},"references-count":42,"alternative-id":["10.3389\/fsurg.2026.1800991"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2026.1800991","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,15]]},"article-number":"1800991"}}