{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T06:03:16Z","timestamp":1780984996641,"version":"3.54.1"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T00:00:00Z","timestamp":1780963200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:p>\n                    Emergency management of post-dissection thoracoabdominal aortic aneurysm (pd-TAAA) in patients with complex anatomy, multiple comorbidities, and severely compromised physiological reserve presents a formidable challenge. Achieving accurate and safe endovascular rescue is extremely difficult, particularly in resource-limited environments where custom-made devices are not available. A 56-year-old male was admitted emergently with a giant Crawford extent II pd-TAAA measuring 71\u2005mm in maximum diameter, complicated by a concomitant left renal artery aneurysm and reduced physiological reserve, including renal and hepatic insufficiency. Due to urgent symptoms and unavailability of off-the-shelf branched stent grafts, total endovascular repair was performed using a 3D-printed model-guided physician-modified stent graft system (PMSGS). This technique utilizes\n                    <jats:italic>in vitro<\/jats:italic>\n                    replication of the patient's anatomy to achieve accurate alignment between stent fenestrations and visceral artery ostia. Intraoperatively, a stent-assisted coil embolization strategy was applied to exclude the renal artery aneurysm, achieving \u201czero warm ischemia\u201d protection for the kidney. Concurrently, a multimodal neuroprotective strategy, including the use of an iliac branch endoprosthesis and cerebrospinal fluid drainage, was utilized. Postoperative imaging confirmed complete aneurysm exclusion, patent visceral branches, and absence of spinal cord ischemia or renal function deterioration. This case elucidates that for pd-TAAA patients with complex anatomy and multiple high-risk factors in emergency settings, the 3D-printed model-guided PMSGS technique provides an accurate and effective alternative treatment strategy. Integration of this technique with comprehensive perioperative management efficiently solves anatomical matching difficulties and maximizes organ protection in the absence of custom-made devices.\n                  <\/jats:p>","DOI":"10.3389\/fsurg.2026.1802270","type":"journal-article","created":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T05:42:43Z","timestamp":1780983763000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Total endovascular repair of a post-TEVAR Crawford extent II thoracoabdominal aortic aneurysm with concomitant renal artery aneurysm: a case report"],"prefix":"10.3389","volume":"13","author":[{"given":"Xingbo","family":"Cao","sequence":"first","affiliation":[{"name":"North Sichuan Medical College","place":["Nanchong, China"]},{"name":"Center of Vascular and Interventional Surgery, Department of General Surgery, The Third People's Hospital of Chengdu, Affiliated Hospital of Southwest Jiaotong University & The Second Affiliated Hospital of Chengdu, Chongqing Medical University","place":["Chengdu, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Liu","sequence":"additional","affiliation":[{"name":"Center of Vascular and Interventional Surgery, Department of General Surgery, The Third People's Hospital of Chengdu, Affiliated Hospital of Southwest Jiaotong University & The Second Affiliated Hospital of Chengdu, Chongqing Medical University","place":["Chengdu, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miao","family":"Chen","sequence":"additional","affiliation":[{"name":"Center of Vascular and Interventional Surgery, Department of General Surgery, The Third People's Hospital of Chengdu, Affiliated Hospital of Southwest Jiaotong University & The Second Affiliated Hospital of Chengdu, Chongqing Medical University","place":["Chengdu, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chi","family":"Cui","sequence":"additional","affiliation":[{"name":"Center of Vascular and Interventional Surgery, Department of General Surgery, The Third People's Hospital of Chengdu, Affiliated Hospital of Southwest Jiaotong University & The Second Affiliated Hospital of Chengdu, Chongqing Medical University","place":["Chengdu, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,6,9]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e334","DOI":"10.1161\/CIR.0000000000001106","article-title":"2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association\/American College of Cardiology joint committee on clinical practice guidelines","volume":"146","author":"Isselbacher","year":"2022","journal-title":"Circulation"},{"key":"B2","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1161\/CIRCINTERVENTIONS.113.000463","article-title":"Endovascular repair of type B aortic dissection: long-term results of the randomized investigation of stent grafts in aortic dissection trial","volume":"6","author":"Nienaber","year":"2013","journal-title":"Circ Cardiovasc Interv"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.jtcvs.2015.12.050","article-title":"Outcomes of 3309 thoracoabdominal aortic aneurysm repairs","volume":"151","author":"Coselli","year":"2016","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B4","doi-asserted-by":"publisher","first-page":"6998","DOI":"10.3390\/jcm14196998","article-title":"Staging strategies during complex endovascular aortic procedures to minimize spinal cord ischemia rates: a narrative review","volume":"14","author":"Grandi","year":"2025","journal-title":"J Clin Med"},{"key":"B5","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1007\/s11748-016-0658-8","article-title":"Open aortic surgery after thoracic endovascular aortic repair","volume":"64","author":"Coselli","year":"2016","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"B6","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1016\/j.jvs.2019.10.091","article-title":"Outcomes of endovascular repair of chronic postdissection compared with degenerative thoracoabdominal aortic aneurysms using fenestrated-branched stent grafts","volume":"72","author":"Tenorio","year":"2020","journal-title":"J Vasc Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/j.jvs.2012.02.011","article-title":"Physician-modified endovascular grafts for the treatment of elective, symptomatic, or ruptured juxtarenal aortic aneurysms","volume":"56","author":"Starnes","year":"2012","journal-title":"J Vasc Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1007\/s00270-020-02424-2","article-title":"Use of 3D printing to guide creation of fenestrations in physician-modified stent-grafts for total endovascular repair of thoracoabdominal aortic disease","volume":"43","author":"Tong","year":"2020","journal-title":"Cardiovasc Intervent Radiol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"3S","DOI":"10.1016\/j.jvs.2020.01.039","article-title":"The society for vascular surgery clinical practice guidelines on the management of visceral aneurysms","volume":"72","author":"Chaer","year":"2020","journal-title":"J Vasc Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.eururo.2010.05.047","article-title":"Every minute counts when the renal hilum is clamped during partial nephrectomy","volume":"58","author":"Thompson","year":"2010","journal-title":"Eur Urol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1016\/j.jvs.2015.10.095","article-title":"Fenestrated and branched endovascular aneurysm repair outcomes for type II and III thoracoabdominal aortic aneurysms","volume":"63","author":"Eagleton","year":"2016","journal-title":"J Vasc Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.jvs.2016.12.111","article-title":"Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms","volume":"66","author":"Schanzer","year":"2017","journal-title":"J Vasc Surg"},{"key":"B13","first-page":"351","article-title":"The mechanism of paraplegia after temporary thoracic aortic occlusion and its relationship to spinal fluid pressure","volume":"51","author":"Blaisdell","year":"1962","journal-title":"Surgery"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.1016\/j.jvs.2023.01.188","article-title":"Comparison of single- and multistage strategies during fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms","volume":"77","author":"Dias-Neto","year":"2023","journal-title":"J Vasc Surg"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1802270\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T05:42:48Z","timestamp":1780983768000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1802270\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,9]]},"references-count":14,"alternative-id":["10.3389\/fsurg.2026.1802270"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2026.1802270","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,9]]},"article-number":"1802270"}}