{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T06:05:14Z","timestamp":1784009114500,"version":"3.55.0"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:00:00Z","timestamp":1783987200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Numerous surgical strategies are available for displaced patellar fractures, yet a universally accepted treatment standard remains lacking. Internal fixation constructed on the tension-band principle constitutes the primary treatment modality for such injuries. This study aimed to evaluate the clinical outcomes of two cannulated screw tension-band fixation techniques combined with cerclage fixation for displaced patellar fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective study was conducted on patients with displaced patellar fractures. The patients were divided into the group I treated with modified cross cannulated screws tension band and cerclage fixation, and the group II treated with parallel cannulated screws tension band and cerclage fixation. Baseline data, intraoperative variables, fracture healing status, complications, and B\u00f6stman scores were compared between the two groups to assess clinical efficacy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      All patients in both groups were followed up for 2 years. Two patients in Group II presented with anterior patellar discomfort, whereas no adverse events were recorded in Group I. Bony union was achieved in all cases of both groups. There were no significant differences in incision length, hospital stay, fracture healing time, or complications between the two groups (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;gt;\u20090.05). The operation time, intraoperative blood loss, and fluoroscopy times in the group I were higher than those in the group II (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05). The B\u00f6stman scores of both groups at 6 months after surgery were significantly lower than those before surgery (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05), and there was no statistically difference between the two groups at 6 months after surgery (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;gt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Both cannulated screws tension band combined with cerclage fixation can achieve good clinical efficacy in the treatment of patellar fractures. The operation time, intraoperative blood loss, and fluoroscopy times in the cross cannulated screws tension band group are higher than those in the parallel cannulated screws tension band group. In clinical practice, the cross screw insertion method can be considered when fracture comminution makes parallel screw placement difficult.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fsurg.2026.1808022","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T05:40:14Z","timestamp":1784007614000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical application of cannulated screws tension band and cerclage fixation for displaced patellar fractures based on fracture morphological classification"],"prefix":"10.3389","volume":"13","author":[{"given":"Yong-Long","family":"Qiu","sequence":"first","affiliation":[{"name":"The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University","place":["Wuhan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ya-Ping","family":"Xiao","sequence":"additional","affiliation":[{"name":"The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University","place":["Wuhan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Li","sequence":"additional","affiliation":[{"name":"The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University","place":["Wuhan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian-Zhong","family":"Chang","sequence":"additional","affiliation":[{"name":"The Department of Orthopedic Surgery, CR & WISCO General Hospital Affiliated to Wuhan University of Science and Technology","place":["Wuhan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,14]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"w20165","DOI":"10.4414\/smw.2020.20165","article-title":"Practical guidelines for the treatment of patellar fractures in adults","volume":"150","author":"Steinmetz","year":"2020","journal-title":"Swiss Med Wkly"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1633670","DOI":"10.3389\/fsurg.2025.1633670","article-title":"Comparison of the therapeutic effects of three internal fixation methods for transverse fractures of the patella","volume":"12","author":"Li","year":"2025","journal-title":"Front Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1377921","DOI":"10.3389\/fsurg.2024.1377921","article-title":"Novel technique for comminuted patellar fixation using suture tape in spiderweb configuration","volume":"11","author":"Tee","year":"2024","journal-title":"Front Surg"},{"key":"B4","doi-asserted-by":"publisher","first-page":"5997","DOI":"10.1097\/js9.0000000000001714","article-title":"Managing complications in patellar fracture surgery: tension band wiring challenges and innovations","volume":"110","author":"Peng","year":"2024","journal-title":"Int J Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1594907","DOI":"10.3389\/fsurg.2025.1594907","article-title":"Comparative clinical outcomes of dual cannulated screw-cable system vs. Kirschner wire-cable fixation in type C patellar fractures","volume":"12","author":"Yang","year":"2025","journal-title":"Front Surg"},{"key":"B6","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1016\/j.jsurg.2024.03.002","article-title":"Patellar fracture surgery performed autonomously by residents, yields similar short-term outcomes to surgery performed by fellowship-trained surgeons","volume":"81","author":"Balziano","year":"2024","journal-title":"J Surg Educ"},{"key":"B7","doi-asserted-by":"publisher","first-page":"244","DOI":"10.5435\/jaaos-d-20-00591","article-title":"Patella fractures: approach to treatment","volume":"29","author":"Hargett","year":"2021","journal-title":"J Am Acad Orthop Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3233\/thc-220133","article-title":"Observation of the effect of arthroscopically assisted percutaneous minimally invasive Kirschner wire tension band fixation on the treatment of patellar fractures","volume":"31","author":"Mei","year":"2023","journal-title":"Technol Health Care"},{"key":"B9","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1186\/s12893-023-02153-w","article-title":"Management of comminuted patellar fractures using suture reduction technique combined with the modified Kirschner-wire tension band","volume":"23","author":"Huang","year":"2023","journal-title":"BMC Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s43465-021-00498-z","article-title":"Comparison of functional and radiological outcomes of transverse patellar fractures fixed with tension band fixation using cannulated screws and Kirschner wires: a prospective randomized study","volume":"56","author":"Drolia","year":"2022","journal-title":"Indian J Orthop"},{"key":"B11","doi-asserted-by":"publisher","first-page":"4065978","DOI":"10.1155\/2020\/4065978","article-title":"Comparison of the therapeutic effects of tension band with cannulated screw and tension band with Kirschner wire on Patella fracture","volume":"2020","author":"Liu","year":"2020","journal-title":"Comput Math Methods Med"},{"key":"B12","doi-asserted-by":"publisher","first-page":"653","DOI":"10.2106\/jbjs.K.01549","article-title":"Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires","author":"Hoshino","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"B13","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1186\/s13018-025-05926-6","article-title":"Krackow suturing combined with the suture-bridge technique versus Kirschner-wire tension band combined with patellar cerclage for the treatment of inferior pole patella fracture: a retrospective comparative study","volume":"20","author":"Yan","year":"2025","journal-title":"J Orthop Surg Res"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.21037\/apm-22-208","article-title":"Percutaneous minimally invasive treatment of transverse patellar fracture using cannulated screws combined with high-strength sutures and nice knots: a retrospective study","volume":"11","author":"Jia","year":"2022","journal-title":"Ann Palliat Med"},{"key":"B15","doi-asserted-by":"publisher","first-page":"e1447","DOI":"10.1016\/j.eats.2021.02.008","article-title":"Patellar fracture fixation with cannulated compression screws and FiberTape cerclage","volume":"10","author":"Posner","year":"2021","journal-title":"Arthrosc Tech"},{"key":"B16","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1007\/s00402-025-05969-8","article-title":"Cannulated screws with and without tension band wiring versus tension banding wiring alone for fixation of patella fractures: a systematic review and meta-analysis","volume":"145","author":"Tijare","year":"2025","journal-title":"Arch Orthop Trauma Surg"},{"key":"B17","volume-title":"Rockwood and Green\u2019s Fractures in Adults. 6th Edn","author":"Bucholz","year":"2006"},{"key":"B18","doi-asserted-by":"publisher","first-page":"968535","DOI":"10.3389\/fsurg.2022.968535","article-title":"Clinical application of kirschner wires combined with 5-ethibond fixation for patella fractures","volume":"9","author":"Liang","year":"2022","journal-title":"Front Surg"},{"key":"B19","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.2106\/jbjs.20.01478","article-title":"Patellar fractures: anatomy, mechanics, and surgical management","volume":"103","author":"Howatt","year":"2021","journal-title":"J Bone Joint Surg Am"},{"key":"B20","doi-asserted-by":"publisher","first-page":"e70105","DOI":"10.1002\/jor.70105","article-title":"Primary stability of a new TendoClip fixation for tuberosity refixation in total shoulder arthroplasty","volume":"44","author":"Uhler","year":"2026","journal-title":"J Orthop Res"},{"key":"B21","doi-asserted-by":"publisher","first-page":"e92343","DOI":"10.7759\/cureus.92343","article-title":"Surgical outcomes following Patella fracture repair: a single-center retrospective cohort study","volume":"17","author":"Feathers","year":"2025","journal-title":"Cureus"},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-026-04689-y","article-title":"Spitler: early complications associated with fixation constructs of operatively treated patella fractures: a retrospective study","volume":"36","author":"Litten","year":"2026","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.cjtee.2021.02.009","article-title":"Comparison of the clinical efficacy of different fixation systems for the treatment of transverse patellar fractures","volume":"24","author":"Bai","year":"2021","journal-title":"Chin J Traumatol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1186\/s12891-020-03744-x","article-title":"Role of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire","volume":"21","author":"Chang","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"B25","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1186\/s12891-020-03936-5","article-title":"A retrospective cohort study on prevalence of postoperative complications in comminuted patellar fractures: comparisons among stabilized with cannulated-screw, Kirschner-wire, or ring-pin tension bands","volume":"22","author":"Zhu","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"B26","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.injury.2019.10.002","article-title":"Patella fractures treated with cannulated lag screws and fiberwire\u00ae have a high union rate and low rate of implant removal","volume":"51","author":"Busel","year":"2020","journal-title":"Injury"},{"key":"B27","doi-asserted-by":"publisher","first-page":"2309499019882140","DOI":"10.1177\/2309499019882140","article-title":"Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins","volume":"27","author":"Lee","year":"2019","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.injury.2020.03.030","article-title":"Biomechanical comparison of a 3.5\u2005mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures","volume":"51","author":"Wagner","year":"2020","journal-title":"Injury"},{"key":"B29","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s00113-025-01647-x","article-title":"Patellar fractures: modern treatment concepts in clinical routine practice","volume":"129","author":"Kylies","year":"2026","journal-title":"Unfallchirurgie (Heidelb)"},{"key":"B30","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1097\/bot.0000000000003025","article-title":"Excellent results with low reoperation rates after fixation of Patella fractures with a new anatomically contoured plating system","volume":"39","author":"Shaath","year":"2025","journal-title":"J Orthop Trauma"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1808022\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T05:40:15Z","timestamp":1784007615000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1808022\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,14]]},"references-count":30,"alternative-id":["10.3389\/fsurg.2026.1808022"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2026.1808022","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,14]]},"article-number":"1808022"}}