{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T06:49:47Z","timestamp":1791355787908,"version":"4.3.1"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Surg."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aims to validate the effectiveness of this device in collecting distension fluid during hysteroscopic surgery, providing a more reliable tool for monitoring fluid outflow.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 164 patients scheduled for elective hysteroscopy were randomly assigned in a 1:1 ratio to either the precision collection group or the control group. The precision collection group utilized a precision distension fluid collection device for hysteroscopic distension fluid collection, while the control group used a conventional collection device. The primary outcome was the hysteroscopic distension fluid collection rate. Secondary outcomes included the incidence of adverse events, operating room cleaning time, and satisfaction levels of surgeons, nurses, and operating room support staff.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There were no significant differences in baseline patient characteristics or surgical types between the two groups. Compared to the conventional fluid collection device, the precision distension fluid collection device significantly improved the hysteroscopic distension fluid collection rate (95% vs. 48%,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001) and reduced the operating room turnover time for staff (4.1 min vs. 6.4 min,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001), while also substantially increasing surgical team satisfaction.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The precision distension fluid collection device effectively enhances the collection rate of hysteroscopic distension fluid, reduces risks associated with improper fluid management, shortens operating room turnover time, and improves the satisfaction of the surgical team.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Trial Registration<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link>https:\/\/www.chictr.org.cn<\/jats:ext-link>\n                      , identifier ChiCTR2500101460.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fsurg.2026.1894370","type":"journal-article","created":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T05:52:20Z","timestamp":1791352340000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of collection efficiency and safety of a precise distention fluid collection device compared to traditional devices in hysteroscopic surgery"],"prefix":"10.3389","volume":"13","author":[{"given":"Yongli","family":"Ying","sequence":"first","affiliation":[{"name":"Department of Operation Room, The First Affiliated Hospital of Lishui University, Lishui People's Hospital","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haiyan","family":"Lan","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, The First Affiliated Hospital of Lishui University, Lishui People's Hospital","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.bpobgyn.2005.10.002","article-title":"Hysteroscopic surgery","volume":"20","author":"Sutton","year":"2006","journal-title":"Best Pract Res Clin Obstet Gynaecol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1097\/00006250-200008000-00021","article-title":"Complications of hysteroscopy: a prospective, multicenter study","volume":"96","author":"Jansen","year":"2000","journal-title":"Obstet Gynecol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/S0301-2115(02)00106-9","article-title":"A multicenter survey of complications associated with 21,676 operative hysteroscopies","volume":"104","author":"Aydeniz","year":"2002","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1053\/bean.2002.0206","article-title":"Anaesthetic considerations for hysteroscopic surgery","volume":"16","author":"Mushambi","year":"2002","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"B5","first-page":"373","article-title":"Hypotonic and isotonic fluid overload as a complication of hysteroscopic procedures: two case reports","volume":"76","author":"Van Kruchten","year":"2010","journal-title":"Minerva Anestesiol"},{"key":"B6","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.jmig.2012.08.778","article-title":"Operative hysteroscopy in an office-based surgical setting: review of patient safety and satisfaction in 414 cases","volume":"20","author":"Wortman","year":"2013","journal-title":"J Minim Invasive Gynecol"},{"key":"B7","doi-asserted-by":"publisher","first-page":"S44","DOI":"10.4097\/kjae.2013.65.6S.S44","article-title":"Operative hysteroscopy intravascular absorption syndrome caused by massive absorption of 0.9% saline as the distention\/irrigation medium","volume":"65","author":"Kim","year":"2013","journal-title":"Korean J Anesthesiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"451","DOI":"10.12891\/ceog17502014","article-title":"Experience of hysteroscopy indications and complications in 5,474 cases","volume":"41","author":"Kayatas","year":"2014","journal-title":"Clin Exp Obstet Gynecol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"387","DOI":"10.4097\/kja.d.18.00374","article-title":"Complications of fluid overload during hysteroscopic surgery","volume":"72","author":"Hoffman","year":"2019","journal-title":"Korean J Anesthesiol"},{"key":"B10","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.jmig.2012.12.002","article-title":"AAGL practice report: practice guidelines for the management of hysteroscopic distending media: (replaces hysteroscopic fluid monitoring guidelines","volume":"20","author":"Munro","year":"2013","journal-title":"J Minim Invasive Gynecol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1001\/jama.1993.03510100080037","article-title":"Endometrial ablation complicated by fatal hyponatremic encephalopathy","volume":"270","author":"Arieff","year":"1993","journal-title":"JAMA"},{"key":"B12","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.jogc.2021.10.015","article-title":"Hysteroscopic fluid overload: prevention, prevention, prevention","volume":"44","author":"Tulandi","year":"2022","journal-title":"J Obstet Gynaecol Can"},{"key":"B13","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s10397-016-0983-z","article-title":"BSGE\/ESGE guideline on management of fluid distension media in operative hysteroscopy","volume":"13","author":"Umranikar","year":"2016","journal-title":"Gynecol Surg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1016\/j.bpobgyn.2015.03.009","article-title":"Complications of hysteroscopy and how to avoid them","volume":"29","author":"McGurgan","year":"2015","journal-title":"Best Pract Res Clin Obstet Gynaecol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1016\/j.fertnstert.2008.01.083","article-title":"A randomized trial comparing monopolar electrodes using glycine 1.5% with two different types of bipolar electrodes (TCRis, versapoint) using saline, in hysteroscopic surgery","volume":"91","author":"Berg","year":"2009","journal-title":"Fertil Steril"},{"key":"B16","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1016\/S0015-0282(16)56268-2","article-title":"Complications associated with the absorption of hysteroscopic fluid media","volume":"60","author":"Witz","year":"1993","journal-title":"Fertil Steril"},{"key":"B17","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1016\/S0001-2092(06)63267-5","article-title":"Preventing intravasation in women undergoing hysteroscopic procedures","volume":"64","author":"Bennettw","year":"1996","journal-title":"AORN J"},{"key":"B18","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1016\/j.jclinane.2008.05.026","article-title":"Acute pulmonary edema from unrecognized high irrigation pressure in hysteroscopy: a report of two cases","volume":"20","author":"Hsieh","year":"2008","journal-title":"J Clin Anesth"},{"key":"B19","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1002\/ijgo.15860","article-title":"Good practice with fluid management in operative hysteroscopy","volume":"168","author":"Vilos","year":"2025","journal-title":"Int J Gynaecol Obstet"},{"key":"B20","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1093\/bja\/aei279","article-title":"Fluid absorption in endoscopic surgery","volume":"96","author":"Hahn","year":"2006","journal-title":"Br J Anaesth"},{"key":"B21","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/S1074-3804(05)60359-3","article-title":"Sources of error when tracking irrigation fluids during hysteroscopic procedures","volume":"7","author":"Boyd","year":"2000","journal-title":"J Am Assoc Gynecol Laparosc"},{"key":"B22","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.jmig.2007.03.007","article-title":"Investigation of often-reported ten percent hysteroscopy fluid overfill: is this accurate?","volume":"14","author":"Nezhat","year":"2007","journal-title":"J Minim Invasive Gynecol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1097\/AOG.0000000000004604","article-title":"A fluid-management drape for hysteroscopy","volume":"138","author":"Marshburn","year":"2021","journal-title":"Obstet Gynecol"},{"key":"B24","first-page":"590","article-title":"American association of gynecologic laparoscopists\u2019 1988 membership survey on operative hysteroscopy","volume":"35","author":"Peterson","year":"1990","journal-title":"J Reprod Med"},{"key":"B25","first-page":"572","article-title":"Operative hysteroscopy. American association of gynecologic laparoscopists 1991 membership survey","volume":"38","author":"Hulka","year":"1993","journal-title":"J Reprod Med"},{"key":"B26","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1196\/annals.1365.019","article-title":"Safety issues of hysteroscopic surgery","volume":"1092","author":"Paschopoulos","year":"2006","journal-title":"Ann N Y Acad Sci."},{"key":"B27","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1016\/j.juro.2007.07.038","article-title":"Bipolar transurethral resection in saline--an alternative surgical treatment for bladder outlet obstruction?","volume":"178","author":"Michielsen","year":"2007","journal-title":"J Urol"},{"key":"B28","doi-asserted-by":"publisher","first-page":"228","DOI":"10.3109\/00365591003720275","article-title":"Bipolar transurethral resection in saline: the solution to avoid hyponatraemia and transurethral resection syndrome","volume":"44","author":"Michielsen","year":"2010","journal-title":"Scand J Urol Nephrol"}],"container-title":["Frontiers in Surgery"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1894370\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T05:52:21Z","timestamp":1791352341000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fsurg.2026.1894370\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,7]]},"references-count":28,"alternative-id":["10.3389\/fsurg.2026.1894370"],"URL":"https:\/\/doi.org\/10.3389\/fsurg.2026.1894370","relation":{},"ISSN":["2296-875X"],"issn-type":[{"value":"2296-875X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,7]]},"article-number":"1894370"}}