{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T22:30:34Z","timestamp":1778279434996,"version":"3.51.4"},"reference-count":47,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Vet. Sci."],"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>This study aimed to evaluate lung overinflation at different airway inspiratory pressure levels using computed tomography in cats undergoing general anesthesia.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design<\/jats:title><jats:p>Prospective laboratory study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Animals<\/jats:title><jats:p>A group of 17 healthy male cats, aged 1.9\u20134.5 years and weighing 3.5 \u00b1 0.5 kg.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Seventeen adult male cats were ventilated in pressure-controlled mode with airway pressure stepwise increased from 5 to 15 cmH<jats:sub>2<\/jats:sub>O in 2 cmH<jats:sub>2<\/jats:sub>O steps every 5 min and then stepwise decreased. The respiratory rate was set at 15 movements per min and end-expiratory pressure at zero (ZEEP). After 5 min in each inspiratory pressure step, a 4 s inspiratory pause was performed to obtain a thoracic juxta-diaphragmatic single slice helical CT image and to collect respiratory mechanics data and an arterial blood sample. Lung parenchyma aeration was defined as overinflated, normally-aerated, poorly-aerated, and non-aerated according to the CT attenuation number (\u22121,000 to \u2212900 HU, \u2212900 to \u2212500 HU, \u2212500 to \u2212100 HU, and \u2212100 to +100 HU, respectively).<\/jats:p><\/jats:sec><jats:sec><jats:title>Result<\/jats:title><jats:p>At 5 cmH<jats:sub>2<\/jats:sub>O airway pressure, tidal volume was 6.7\u00b1 2.2 ml kg<jats:sup>\u22121<\/jats:sup>, 2.1% (0.3\u20136.3%) of the pulmonary parenchyma was overinflated and 84.9% (77.6%\u221287.6%) was normally inflated. Increases in airway pressure were associated with progressive distention of the lung parenchyma. At 15 cmH<jats:sub>2<\/jats:sub>O airway pressure, tidal volume increased to 31.5\u00b1 9.9 ml kg<jats:sup>\u22121<\/jats:sup>(<jats:italic>p<\/jats:italic>&amp;lt; 0.001), overinflated pulmonary parenchyma increased to 28.4% (21.2\u201330.6%) (<jats:italic>p<\/jats:italic>&amp;lt; 0.001), while normally inflated parenchyma decreased 57.9% (53.4\u201362.8%) (<jats:italic>p<\/jats:italic>&amp;lt; 0.001). Tidal volume and overinflated lung fraction returned to baseline when airway pressure was decreased. A progressive decrease was observed in arterial carbon dioxide partial pressure (PaCO<jats:sub>2<\/jats:sub>) and end-tidal carbon dioxide (ETCO<jats:sub>2<\/jats:sub>) when the airway pressures were increased above 9 cmH<jats:sub>2<\/jats:sub>O (<jats:italic>p<\/jats:italic>&amp;lt; 0.001). The increase in airway pressure promoted an elevation in pH (<jats:italic>p<\/jats:italic>&amp;lt; 0.001).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions and Clinical Relevance<\/jats:title><jats:p>Ventilation with 5 and 7 cmH<jats:sub>2<\/jats:sub>O of airway pressure prevents overinflation in healthy cats with highly compliant chest walls, despite presenting acidemia by respiratory acidosis. This fact can be controlled by increasing or decreasing respiratory rate and inspiratory time.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fvets.2022.842528","type":"journal-article","created":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T10:38:27Z","timestamp":1648809507000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Computed Tomography Assessment of Tidal Lung Overinflation in Domestic Cats Undergoing Pressure-Controlled Mechanical Ventilation During General Anesthesia"],"prefix":"10.3389","volume":"9","author":[{"given":"Alessandro R. C.","family":"Martins","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aline M.","family":"Ambr\u00f3sio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denise T.","family":"Fantoni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana Carolina B. C. F.","family":"Pinto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lenin Arturo","family":"Villamizar-Martinez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jo\u00e3o H. N.","family":"Soares","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denise A.","family":"Otsuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luiz Marcelo S.","family":"Malbouisson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,4,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"985923","DOI":"10.1100\/2012\/985923","article-title":"Alveolar overdistension as a cause of lung injury: differences among three animal species","volume":"2012","author":"Garc\u00eda-Delgado","year":"2012","journal-title":"Sci World J."},{"key":"B2","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1097\/00000542-200504000-00021","article-title":"Pulmonary atelectasis: a pathogenic perioperative entity","volume":"102","author":"Duggan","year":"2005","journal-title":"Anesthesiology."},{"key":"B3","first-page":"315","article-title":"Atelectasis formation and gas exchange impairment during anaesthesia","volume":"49","author":"Hedenstierna","year":"1994","journal-title":"Monaldi Arch Chest Dis."},{"key":"B4","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1111\/j.1399-6576.1992.tb03516.x","article-title":"Atelectasis and lung function in the postoperative period","volume":"36","author":"Lindberg","year":"1992","journal-title":"Acta Anaesthesiol Scand."},{"key":"B5","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/2110-5820-1-28","article-title":"Ventilator-induced lung injury: historical perspectives and clinical implications","volume":"1","author":"De Proste","year":"2011","journal-title":"Ann Intensive Care."},{"key":"B6","doi-asserted-by":"publisher","first-page":"2126","DOI":"10.1056\/NEJMra1208707","article-title":"Ventilator-induced lung injury.","volume":"369","author":"Slutsky","year":"2013","journal-title":"N Engl J Med."},{"key":"B7","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1056\/NEJMoa1301082","article-title":"A trial of intraoperative low-tidal-volume ventilation in abdominal surgery","volume":"369","author":"Futier","year":"2013","journal-title":"N Engl J Med."},{"key":"B8","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1007\/s001340100860","article-title":"Validation of a software designed for computed tomographic (CT) measurement of lung water","volume":"27","author":"Malbouisson","year":"2001","journal-title":"Intensive Care Med."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1164\/ajrccm.158.5.9802101","article-title":"A lung computed tomographic assessment of positive end-expiratory pressure-induced lung overdistension","volume":"158","author":"Vieira","year":"1998","journal-title":"Am J Respir Crit Care Med."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1496","DOI":"10.1097\/01.CCM.0000130170.88512.07","article-title":"Incidence and regional distribution of lung overinflation during mechanical ventilation with positive end-expiratory pressure","volume":"32","author":"Nieszkowska","year":"2004","journal-title":"Crit Care Med."},{"key":"B11","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1164\/ajrccm.149.1.8111603","article-title":"Vertical gradient of regional lung inflation in adult respiratory distress syndrome","volume":"149","author":"Pelosi","year":"1994","journal-title":"Am J Respir Crit Care Med."},{"key":"B12","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1164\/rccm.200607-915OC","article-title":"Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome","volume":"175","author":"Terragni","year":"2007","journal-title":"Am J Respir Crit Care Med."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.2214\/ajr.143.5.1101","article-title":"Mass estimates by computed tomography: physical density from CT numbers","volume":"143","author":"Mull","year":"1984","journal-title":"Am J Roentgenol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1164\/ajrccm\/137.2.380","article-title":"CT measurements of lung density in life can quantitate distal airspace enlargement\u2013an essential defining feature of human emphysema","volume":"137","author":"Gould","year":"1988","journal-title":"Am Rev Respir Dis."},{"key":"B15","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1164\/ajrccm.154.1.8680679","article-title":"Comparison of computed density and microscopic morphometry in pulmonary emphysema","volume":"154","author":"Gevenois","year":"1996","journal-title":"Am J Respir Crit Care Med."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1164\/ajrccm.158.5.9802003","article-title":"computed tomography scan assessment of regional lung volume in acute lung injury. The CT scan ARDS study group","volume":"158","author":"Puybasset","year":"1998","journal-title":"Am J Respir Crit Care Med."},{"key":"B17","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1183\/09031936.93.02060528","article-title":"Pulmonary densities during anaesthesia. An experimental study on lung morphology and gas exchange","volume":"2","author":"Hedenstierna","year":"1989","journal-title":"Eur Respir J."},{"key":"B18","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1164\/ajrccm.157.1.9604014","article-title":"Ventilator-induced lung injury: lessons from experimental studies","volume":"157","author":"Dreyfuss","year":"1998","journal-title":"Am J Respir Crit Care Med."},{"key":"B19","first-page":"556","article-title":"Experimental pulmonary edema due to intermittent positive pressure ventilation with high inflation pressures. Protection by positive end-expiratory pressure","volume":"110","author":"Webb","year":"1974","journal-title":"Am Rev Respir Dis."},{"key":"B20","first-page":"880","article-title":"Intermittent positive-pressure hyperventilation with high inflation pressures produces pulmonary microvascular injury in rats","volume":"132","author":"Dreyfuss","year":"1985","journal-title":"Am Rev Respir Dis."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1164\/ajrccm\/137.5.1159","article-title":"High inflation pressure pulmonary edema. Respective effects of high airway pressure, high tidal volume, and positive end-expiratory pressure","volume":"137","author":"Dreyfuss","year":"1988","journal-title":"Am Rev Respir Dis."},{"key":"B22","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1152\/jappl.1990.69.2.577","article-title":"Lung overexpansion increases pulmonary microvascular protein permeability in young lambs","volume":"69","author":"Carlton","year":"1990","journal-title":"J Appl Physiol."},{"key":"B23","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.3389\/fimmu.2018.01477","article-title":"High tidal volume induces mitochondria damage and releases mitochondrial DNA to aggravate the ventilator-induced lung injury","volume":"9","author":"Lin","year":"2018","journal-title":"Front Immunol."},{"key":"B24","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1007\/s00134-007-0964-9","article-title":"Effects of mechanical ventilation on the extracellular matrix","volume":"34","author":"Pelosi","year":"2008","journal-title":"Intensive Care Med."},{"key":"B25","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1097\/ALN.0000000000000706","article-title":"Protective versus conventional ventilation for surgery: a systematic review and individual patient data meta-analysis","volume":"123","author":"Serpa Neto","year":"2015","journal-title":"Anesthesiology."},{"key":"B26","doi-asserted-by":"publisher","first-page":"CD011151","DOI":"10.1002\/14651858.CD011151.pub3","article-title":"Intraoperative use of low volume ventilation to decrease postoperative mortality, mechanical ventilation, lengths of stay and lung injury in adults without acute lung injury","volume":"7","author":"Guay","year":"2018","journal-title":"Cochrane Database Syst Rev."},{"key":"B27","first-page":"1149","article-title":"It does not matter whether you are an elephant or a shrew all mammals' tidal volumes are similarly scaled","volume":"80","author":"Villar","year":"2014","journal-title":"Minerva Anesthesiol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1111\/vaa.12276","article-title":"Indexing cardiovascular and respiratory variables: allometric scaling principles","volume":"42","author":"Pypendop","year":"2015","journal-title":"Vet Anaesth Analg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1016\/j.cvsm.2013.03.009","article-title":"Basics of mechanical ventilation for dogs and cats","volume":"43","author":"Hopper","year":"2013","journal-title":"Vet Clin North Am Small Anim Pract."},{"key":"B30","doi-asserted-by":"publisher","first-page":"144","DOI":"10.5935\/0103-507X.20180028","article-title":"Sizing the lung in dogs: the inspiratory capacity defines the tidal volume","volume":"30","author":"Donati","year":"2018","journal-title":"Rev Bras Ter Intensiva."},{"key":"B31","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.vetpar.2012.12.045","article-title":"Lung histopathology, radiography, high-resolution computed tomography, and bronchio-alveolar lavage cytology are altered by Toxocara cati infection in cats and is independent of development of adult intestinal parasites","volume":"193","author":"Dillon","year":"2013","journal-title":"Vet Parasitol."},{"key":"B32","doi-asserted-by":"publisher","first-page":"874","DOI":"10.2460\/ajvr.79.8.874","article-title":"Effect of body position and time on quantitative computed tomographic measurements of lung volume and attenuation in healthy anesthetized cats","volume":"79","author":"Foo","year":"2018","journal-title":"Am J Vet Res."},{"key":"B33","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/S2213-2600(16)00057-6","article-title":"Association between driving pressure and development of postoperative pulmonary complications in patients undergoing mechanical ventilation for general anaesthesia: a meta-analysis of individual patient data","volume":"4","author":"Neto","year":"2016","journal-title":"Lancet Respir Med."},{"key":"B34","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1097\/ALN.0000000000002731","article-title":"Driving pressure and transpulmonary pressure: how do we guide safe mechanical ventilation?","volume":"131","author":"Williams","year":"2019","journal-title":"Anesthesiology."},{"key":"B35","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1111\/jsap.12530","article-title":"Associations between respiratory signs and abnormalities reported thoracic CT scans of cats","volume":"57","author":"Lamb","year":"2016","journal-title":"J small Anim Pract."},{"key":"B36","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1111\/j.1467-2995.2010.00567.x","article-title":"Effects of two fractions of inspired oxygen lung aeration and gas exchange in cats under inhalant anaesthesia","volume":"37","author":"Stafffieri","year":"2010","journal-title":"Vet Anaesth Analg."},{"key":"B37","doi-asserted-by":"publisher","first-page":"925","DOI":"10.2460\/ajvr.68.9.925","article-title":"Computed tomography analysis of the effects of two inspired oxygen concentrations on pulmonary aeration in anesthetized and mechanically ventilated dogs","volume":"68","author":"Stafffieri","year":"2007","journal-title":"Am J Vet Res."},{"key":"B38","doi-asserted-by":"publisher","DOI":"10.1378\/chest.128.5_suppl_2.592S","article-title":"Cardiovascular issues in respiratory care","author":"Pinsky","year":"2005","journal-title":"Chest"},{"key":"B39","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.resp.2006.09.006","article-title":"Non-invasive measurement of total respiratory compliance and resistance in cats","volume":"156","author":"Epstein","year":"2007","journal-title":"Respir Physiol Neurobiol."},{"key":"B40","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.cvsm.2016.10.005","article-title":"A Quick reference on respiratory alkalosis","volume":"47","author":"Johnson","year":"2017","journal-title":"Vet Clin Small Anim."},{"key":"B41","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.cvsm.2016.10.012","article-title":"A quick reference on respiratory acidosis","volume":"47","author":"Johnson","year":"2017","journal-title":"Vet Clin Small Anim."},{"key":"B42","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.cvsm.2016.09.006","article-title":"Respiratory acid-base disorders in the critical care unit","volume":"47","author":"Hopper","year":"2017","journal-title":"Vet Clin Small Anim."},{"key":"B43","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.1007\/s001340101049","article-title":"Assessment of PEEP-induced reopening of collapsed lung regions in acute lung injury: are one or three CT sections representative of the entire lung","volume":"27","author":"Lu","year":"2001","journal-title":"Intensive Care Med."},{"key":"B44","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1001\/jamapediatrics.2013.311","article-title":"The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk","volume":"167","author":"Miglioretti","year":"2013","journal-title":"JAMA Pediatr"},{"key":"B45","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1097\/01.CCM.0000155786.53015.E7","article-title":"Low spatial resolution computed tomography underestimates lung overinflation resulting from positive pressure ventilation","volume":"33","author":"Vieira","year":"2005","journal-title":"Crit Care Med."},{"key":"B46","doi-asserted-by":"publisher","first-page":"R100","DOI":"10.1186\/cc4967","article-title":"Kempski, Markstaller K. Effect of lung recruitment maneuver by high-frequency oscillatory ventilation in experimental acute lung injury on organ blood flow in pigs","volume":"10","author":"David","year":"2006","journal-title":"Crit Care."},{"key":"B47","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1093\/bja\/ael275","article-title":"Quantification of atelectasis lung volumes in two different porcine models ARDS","volume":"97","author":"Karmrodt","year":"2006","journal-title":"B J Anaesth."}],"container-title":["Frontiers in Veterinary Science"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2022.842528\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,31]],"date-time":"2023-01-31T07:58:09Z","timestamp":1675151889000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2022.842528\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,1]]},"references-count":47,"alternative-id":["10.3389\/fvets.2022.842528"],"URL":"https:\/\/doi.org\/10.3389\/fvets.2022.842528","relation":{},"ISSN":["2297-1769"],"issn-type":[{"value":"2297-1769","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,1]]},"article-number":"842528"}}