{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T05:38:34Z","timestamp":1787809114326,"version":"build-2784847793"},"reference-count":31,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Vet. Sci."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>This study aimed to assess the effectiveness of capsule endoscopy in detecting gastric foreign bodies in normal dogs, considering variations in the number of foreign bodies and the gastric environment.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Five healthy male beagles were administered virtual, non-harmful foreign objects that maintained their shape in the stomach. Capsule endoscopy was performed and the images were evaluated by veterinarians and non-veterinarians.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The overall sensitivity and specificity of capsule endoscopy were 99.1 and 90.4%, respectively. Sensitivity and specificity were comparable between veterinarians and non-veterinarians. Sensitivity and specificity in the veterinarian group were 98.7 and 91.2%, respectively, whereas those in the non-veterinarian group were 100 and 88.5%, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>Capsule endoscopy is a valuable alternative diagnostic tool for identifying foreign bodies in the stomach, particularly in challenging cases in which conventional imaging or invasive approaches have limitations.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fvets.2024.1440831","type":"journal-article","created":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T05:00:55Z","timestamp":1723006855000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Detection of foreign bodies in the canine stomach using capsule endoscopy: a randomized trial"],"prefix":"10.3389","volume":"11","author":[{"given":"Ui-Yeon","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Joo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joon Woo","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Munso","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyomi","family":"Jang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong-In","family":"Jung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,8,7]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1038\/35013140","article-title":"Wireless capsule endoscopy","volume":"405","author":"Iddan","year":"2000","journal-title":"Nature"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1053\/gast.2000.20844","article-title":"A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small-bowel lesions","volume":"119","author":"Appleyard","year":"2000","journal-title":"Gastroenterology"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1097\/MPG.0000000000001413","article-title":"NASPGHAN capsule endoscopy clinical report","volume":"64","author":"Friedlander","year":"2017","journal-title":"J Pediatr Gastroenterol Nutr"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1053\/j.gastro.2003.11.057","article-title":"Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases","volume":"126","author":"Pennazio","year":"2004","journal-title":"Gastroenterology"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1053\/j.gastro.2010.01.047","article-title":"Does capsule endoscopy improve outcomes in obscure gastrointestinal bleeding? Randomized trial versus dedicated small bowel radiography","volume":"138","author":"Laine","year":"2010","journal-title":"Gastroenterology"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1053\/j.gastro.2016.12.032","article-title":"Clinical practice guidelines for the use of video capsule endoscopy","volume":"152","author":"Enns","year":"2017","journal-title":"Gastroenterology"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"6140","DOI":"10.3748\/wjg.v13.i46.6140","article-title":"Small bowel capsule endoscopy in 2007: indications, risks and limitations","volume":"13","author":"Rondonotti","year":"2007","journal-title":"World J Gastroenterol"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1016\/j.ijpara.2011.09.005","article-title":"Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs","volume":"41","author":"Lee","year":"2011","journal-title":"Int J Parasitol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.vetpar.2015.08.013","article-title":"Determination of anthelmintic efficacy against Toxocara canis in dogs by use of capsule endoscopy","volume":"212","author":"Lee","year":"2015","journal-title":"Vet Parasitol"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1111\/jsap.12442","article-title":"Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs","volume":"57","author":"Davignon","year":"2016","journal-title":"J Small Anim Pract"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"926","DOI":"10.2460\/javma.249.8.926","article-title":"Multiple gastric erosions diagnosed by means of capsule endoscopy in a dog","volume":"249","author":"Hardy","year":"2016","journal-title":"J Am Vet Med Assoc"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.1111\/jvim.15584","article-title":"Use of video capsule endoscopy to identify gastrointestinal lesions in dogs with microcytosis or gastrointestinal hemorrhage","volume":"33","author":"Mabry","year":"2019","journal-title":"J Vet Intern Med"},{"key":"ref13","first-page":"830","article-title":"Intestinal foreign bodies in dogs and cats","volume":"25","author":"Papazoglou","year":"2003","journal-title":"Compend Contin Educ Pract Vet"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"302","DOI":"10.2460\/javma.245.3.302","article-title":"Sewing needle foreign body ingestion in dogs and cats: 65 cases (2000\u20132012)","volume":"245","author":"Pratt","year":"2014","journal-title":"J Am Vet Med Assoc"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1111\/j.1939-1676.2005.tb02770.x","article-title":"Acid\u2013base and electrolyte abnormalities in dogs with gastrointestinal foreign bodies","volume":"19","author":"Boag","year":"2005","journal-title":"J Vet Intern Med"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1111\/j.1740-8261.2006.00160.x","article-title":"Survey of the use of radiography vs. ultrasonography in the investigation of gastrointestinal foreign bodies in small animals","volume":"47","author":"Tyrrell","year":"2006","journal-title":"Vet Radiol Ultrasound"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1111\/j.1748-5827.2009.00845.x","article-title":"Oesophageal and gastric endoscopic foreign body removal: complications and follow-up of 102 dogs","volume":"50","author":"Gianella","year":"2009","journal-title":"J Small Anim Pract"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1111\/j.1748-5827.2009.00783.x","article-title":"Gastrointestinal foreign bodies in dogs and cats: a retrospective study of 208 cases","volume":"50","author":"Hayes","year":"2009","journal-title":"J Small Anim Pract"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1111\/j.1740-8261.2010.01791.x","article-title":"Comparison of radiography and ultrasonography for diagnosing small-intestinal mechanical obstruction in vomiting dogs","volume":"52","author":"Sharma","year":"2011","journal-title":"Vet Radiol Ultrasound"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1111\/jsap.12271","article-title":"Linear versus non-linear gastrointestinal foreign bodies in 499 dogs: clinical presentation, management and short-term outcome","volume":"55","author":"Hobday","year":"2014","journal-title":"J Small Anim Pract"},{"key":"ref21","first-page":"35","article-title":"Sonographic diagnosis of intestinal obstruction in the dog","volume":"46","author":"Manczur","year":"1998","journal-title":"Acta Vet Hung"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1111\/j.1740-8261.2003.tb00486.x","article-title":"Sonographic signs of gastroduodenal linear foreign body in 3 dogs","volume":"44","author":"Hoffmann","year":"2003","journal-title":"Vet Radiol Ultrasound"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1002\/jcu.20016","article-title":"Sonography in the diagnosis of pediatric gastrointestinal obstruction","volume":"32","author":"Chavhan","year":"2004","journal-title":"J Clin Ultrasound"},{"key":"ref24","first-page":"13","volume-title":"Chapter 2-Abdominal radiography. In: O\u2019Brien R, Barr F, editors. BSAVA manual of canine and feline abdominal imaging. Gloucester: British Small Animal Veterinary Association","author":"McConnell","year":"2009"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"1290","DOI":"10.1016\/j.gie.2010.01.064","article-title":"Remote magnetic manipulation of a wireless capsule endoscope in the esophagus and stomach of humans (with videos)","volume":"71","author":"Swain","year":"2010","journal-title":"Gastrointest Endosc"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.gie.2010.08.053","article-title":"Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers (with videos)","volume":"73","author":"Keller","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1016\/j.gie.2011.09.030","article-title":"Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope","volume":"75","author":"Rey","year":"2012","journal-title":"Gastrointest Endosc"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"155","DOI":"10.4161\/jig.23751","article-title":"Feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human stomach: a pilot study in healthy volunteers","volume":"2","author":"Liao","year":"2012","journal-title":"J Interv Gastroenterol"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1016\/j.gie.2015.09.015","article-title":"Magnetic-assisted capsule endoscopy in the upper GI tract by using a novel navigation system (with video)","volume":"83","author":"Rahman","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.compbiomed.2015.03.014","article-title":"The role of magnetic assisted capsule endoscopy (MACE) to aid visualisation in the upper GI tract","volume":"65","author":"Rahman","year":"2015","journal-title":"Comput Biol Med"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"65","DOI":"10.12729\/jbtr.2019.20.3.065","article-title":"A study on the difference of gastrointestinal transit time with minimized capsule endoscope in dogs","volume":"20","author":"Lee","year":"2019","journal-title":"J Biomed Transl Res"}],"container-title":["Frontiers in Veterinary Science"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2024.1440831\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T05:00:58Z","timestamp":1723006858000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2024.1440831\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,7]]},"references-count":31,"alternative-id":["10.3389\/fvets.2024.1440831"],"URL":"https:\/\/doi.org\/10.3389\/fvets.2024.1440831","relation":{},"ISSN":["2297-1769"],"issn-type":[{"value":"2297-1769","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,7]]},"article-number":"1440831"}}