{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T16:54:42Z","timestamp":1780332882285,"version":"3.54.1"},"reference-count":41,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T00:00:00Z","timestamp":1732147200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Vet. Sci."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Guided endodontics represents an effective method for achieving safe and reliable endodontic surgery in human medicine. However, it is rarely employed in small animal dentistry. This study employed finite element analysis and three-dimensional (3D) printing techniques to explore the feasibility of guided endodontics in Beagle mandibular teeth.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The methodology included the processing of Computed Tomography (CT) data, the creation of mathematical and 3D printing templates of the root canal pathways, and the evaluation of dog 3D printing guided endodontics compared with classic root canal method using radiograph.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In this experiment, the coordinates of the central point of pulp crown and apex point for each tooth were recorded. Based on the extension line of the central point of dental root canal orifice and the apex point, guided endodontic templates were designed on each root canal of 20 teeth in the Beagle mandible. Among them, the average relative deviation of guided endodontics and classic root canal method was 4.28%\u2009 \u00b1\u2009 2.75%, and the mean angular deviation was 1.90\u2009 \u00b1\u2009 0.25\u00b0.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>Our research indicated that dog 3D printing guided endodontics has accurate position, direction, and length, which may assist veterinary dentistry in root canal treatment in small animals.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fvets.2024.1481612","type":"journal-article","created":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T06:28:23Z","timestamp":1732170503000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluating the concept of three-dimensional printing guided endodontics in the dog"],"prefix":"10.3389","volume":"11","author":[{"given":"Jiahui","family":"Peng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruiyu","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haifeng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhijun","family":"Zhong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guangneng","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengli","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziyao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,11,21]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"152041","DOI":"10.1016\/j.aanat.2022.152041","article-title":"Morphological quantification of the maxillary canine tooth in the domestic dog (Canis Lupus Familiaris)","volume":"246","author":"Soukup","year":"2023","journal-title":"Ann Anat"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1111\/iej.13677","article-title":"Present status and future directions: microbiology of endodontic infections","volume":"55","author":"Siqueira","year":"2022","journal-title":"Int Endod J"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"1382645","DOI":"10.3389\/fvets.2024.1382645","article-title":"Outcomes of root canal treatments with three different sealers for 120 fractured maxillary fourth premolar teeth in small-to medium-sized dogs","volume":"11","author":"Kwon","year":"2024","journal-title":"Front Vet Sci"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1177\/08987564231201063","article-title":"Endodontic treatment outcome of 45 incisor teeth in dogs determined by intraoral radiography","volume":"40","author":"Jucan","year":"2023","journal-title":"J Vet Dent"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s12903-024-04377-5","article-title":"Application of personalized templates in minimally invasive management of coronal dens invaginatus: a report of two cases","volume":"22","author":"Li","year":"2024","journal-title":"BMC Oral Health"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"1512","DOI":"10.1016\/j.joen.2011.07.002","article-title":"Analysis of reasons for extraction of Endodontically treated teeth: a prospective study","volume":"37","author":"Tour\u00e9","year":"2011","journal-title":"J Endod"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1186\/s12917-024-04221-6","article-title":"A forecasting model for suitable dental implantation in canine mandibular premolar region based on finite element analysis","volume":"20","author":"Liu","year":"2024","journal-title":"BMC Vet Res"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"8987564241265420","DOI":"10.1177\/08987564241265420","article-title":"Biomechanics of dental implantation in the Giant panda (Ailuropoda Melanoleuca): a comparative study using finite element analysis","author":"Long","year":"2024","journal-title":"J Vet Dent"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"e15317","DOI":"10.1016\/j.heliyon.2023.e15317","article-title":"An in vivo evaluation of clear aligners for optimal orthodontic force and movement to determine high-efficacy and periodontal-friendly aligner staging","volume":"9","author":"Wang","year":"2023","journal-title":"Heliyon"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1111\/iej.13687","article-title":"Present status and future directions - guided endodontics","author":"Connert","year":"2022","journal-title":"Int Endod J"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"221","DOI":"10.23736\/s2724-5691.21.08927-9","article-title":"Application of mimics medical 21.0 software in Thoracoscopic anatomical sublobectomy","volume":"77","author":"You","year":"2022","journal-title":"Minerva Surg"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2023.01.033","article-title":"Influence of print orientation on the accuracy (trueness and precision) of diagnostic casts manufactured with a daylight polymer printer","author":"Maneiro Lojo","year":"2023","journal-title":"J Prosthet Dent"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"698","DOI":"10.18517\/ijaseit.1.6.140","article-title":"Applications of computer aided design (cad) in medical image technology","volume":"1","author":"Shapi'I","year":"2011","journal-title":"Int J Adv Sci Eng Inform Technol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1111\/jerd.12614","article-title":"3d computer-aided treatment planning in periodontology: a novel approach for evaluation and visualization of soft tissue thickness","volume":"32","author":"Kuralt","year":"2020","journal-title":"J Esthet Restor Dent"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"493","DOI":"10.4012\/dmj.2017-064","article-title":"Influence of restorative procedures on Endodontically treated premolars: finite element analysis of a Ct-scan based three-dimensional model","volume":"37","author":"Maravi\u0107","year":"2018","journal-title":"Dent Mater J"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1177\/09544119241232282","article-title":"The comparison between various methods of mandibular reconstruction based on finite element analysis","volume":"238","author":"Parvan","year":"2024","journal-title":"Proc Inst Mech Eng H"},{"key":"ref17","doi-asserted-by":"crossref","DOI":"10.1016\/S0010-4485(00)00078-6","article-title":"From on-line sketching to 2D and 3D geometry: a system based on fuzzy knowledge[J]","volume-title":"Computer-Aided Design","author":"Qin","year":"2000"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1177\/2050168420963306","article-title":"Complications in endodontics","volume":"9","author":"Bhuva","year":"2020","journal-title":"Prim Dent J"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"535","DOI":"10.2460\/javma.21.03.0127","article-title":"Radiographic outcome of root canal treatment in dogs: 281 teeth in 204 dogs (2001-2018)","volume":"260","author":"Lee","year":"2022","journal-title":"J Am Vet Med Assoc"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"775","DOI":"10.2460\/javma.2002.220.775","article-title":"Results of root canal treatment in dogs: 127 cases (1995-2000)","volume":"220","author":"Kuntsi-Vaattovaara","year":"2002","journal-title":"J Am Vet Med Assoc"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.joen.2017.08.029","article-title":"Evaluation of related factors in the failure of Endodontically treated teeth: a cross-sectional study","volume":"44","author":"Olcay","year":"2018","journal-title":"J Endod"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1111\/aej.12240","article-title":"Diagnosis of vertical root fractures in Endodontically treated teeth Utilising digital subtraction radiography: a case series report","volume":"44","author":"Mikrogeorgis","year":"2018","journal-title":"Aust Endod J"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1111\/iej.12544","article-title":"Guided endodontics: accuracy of a novel method for guided access cavity preparation and root canal location","volume":"49","author":"Zehnder","year":"2016","journal-title":"Int Endod J"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1016\/j.joen.2019.03.010","article-title":"Guided endodontics modified for treating molars by using an Intracoronal guide technique","volume":"45","author":"Buchgreitz","year":"2019","journal-title":"J Endod"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1111\/iej.12809","article-title":"Microguided endodontics: a method to achieve minimally invasive access cavity preparation and root canal location in mandibular incisors using a novel computer-guided technique","volume":"51","author":"Connert","year":"2018","journal-title":"Int Endod J"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"e66424","DOI":"10.7759\/cureus.66424","article-title":"Comparative evaluation of three access cavity preparation techniques on root canal instrumentation using Micro-Ct: an in vitro study","volume":"16","author":"Khare","year":"2024","journal-title":"Cureus"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1016\/j.joen.2020.03.014","article-title":"3-dimensional accuracy of dynamic navigation Technology in Locating Calcified Canals","volume":"46","author":"Jain","year":"2020","journal-title":"J Endod"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3290\/j.qi.a41921","article-title":"Computer-aided dynamic navigation: a novel method for guided endodontics","volume":"50","author":"Chong","year":"2019","journal-title":"Quintessence Int"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1111\/iej.13563","article-title":"Dynamic navigation: a laboratory study on the accuracy and potential use of guided root canal treatment","volume":"54","author":"Torres","year":"2021","journal-title":"Int Endod J"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1016\/j.proeng.2011.08.1153","article-title":"Design and simulation based on pro\/E for a hydraulic lift platform in scissors type","volume":"16","author":"Hongyu","year":"2011","journal-title":"Proc Eng"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"169","DOI":"10.11607\/ijp.4148","article-title":"The combination of digital surface scanners and cone beam computed tomography Technology for Guided Implant Surgery Using 3shape implant studio software: a case history report","volume":"28","author":"Lanis","year":"2015","journal-title":"Int J Prosthodont"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1038\/s41746-024-01178-6","article-title":"Accuracy of dental implant placement using different dynamic navigation and robotic systems: an in vitro study","volume":"7","author":"Xu","year":"2024","journal-title":"NPJ Digit Med"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.recot.2020.06.014","article-title":"Role of the Orthopaedic surgeon in 3d printing: current applications and legal issues for a personalized medicine","volume":"65","author":"Andr\u00e9s-Cano","year":"2021","journal-title":"Rev Esp Cir Ortop Traumatol (Engl Ed)"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1016\/j.joen.2013.12.012","article-title":"Impacts of conservative endodontic cavity on root canal instrumentation efficacy and resistance to fracture assessed in incisors, premolars, and molars","volume":"40","author":"Krishan","year":"2014","journal-title":"J Endod"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.joen.2017.01.022","article-title":"Fracture strength of Endodontically treated teeth with different access cavity designs","volume":"43","author":"Plotino","year":"2017","journal-title":"J Endod"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.joen.2018.11.006","article-title":"Guided endodontics versus conventional access cavity preparation: a comparative study on substance loss using 3-dimensional-printed teeth","volume":"45","author":"Connert","year":"2019","journal-title":"J Endod"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1111\/iej.13300","article-title":"Price 2020 guidelines for reporting case reports in endodontics: explanation and elaboration","volume":"53","author":"Nagendrababu","year":"2020","journal-title":"Int Endod J"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1590\/0103-6440202104537","article-title":"Guided endodontics in root canals with complex access: two case reports","volume":"32","author":"Gon\u00e7alves","year":"2021","journal-title":"Braz Dent J"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"e66728","DOI":"10.7759\/cureus.66728","article-title":"The management of a C1-shaped canal configuration in a mandibular second molar","volume":"16","author":"Jidewar","year":"2024","journal-title":"Cureus"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.actbio.2019.03.041","article-title":"Fabrication and mechanical characterization of 3d printed vertical uniform and gradient scaffolds for bone and Osteochondral tissue engineering","volume":"90","author":"Bittner","year":"2019","journal-title":"Acta Biomater"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"S1977","DOI":"10.4103\/jpbs.jpbs_393_24","article-title":"Applications of finite element analysis in endodontics: a systematic review and Meta-analysis","volume":"16","author":"Abdelhafeez","year":"2024","journal-title":"J Pharm Bioallied Sci"}],"container-title":["Frontiers in Veterinary Science"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2024.1481612\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T06:28:28Z","timestamp":1732170508000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2024.1481612\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,21]]},"references-count":41,"alternative-id":["10.3389\/fvets.2024.1481612"],"URL":"https:\/\/doi.org\/10.3389\/fvets.2024.1481612","relation":{},"ISSN":["2297-1769"],"issn-type":[{"value":"2297-1769","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,21]]},"article-number":"1481612"}}