{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T08:34:21Z","timestamp":1773995661631,"version":"3.50.1"},"reference-count":26,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T00:00:00Z","timestamp":1773964800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Vet. Sci."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To develop and report the accuracy and safety of a technique for percutaneous pedicle screw-rod fixation of the thoracolumbar and lumbosacral regions using fluoroscopic guidance in dog cadavers, comparing two levels of surgical experience.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Cadaveric methods comparative study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Animals<\/jats:title>\n                    <jats:p>\n                      Cadaveric vertebral columns of dogs (\n                      <jats:italic>n<\/jats:italic>\n                      \u202f=\u202f3).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Pre-operative computed tomography (CT) scans facilitated in-silico surgical planning. Ideal implant insertion points and trajectory were recorded, and the image was subsequently reconstructed to mimic the appearance of intra-operative fluoroscopy. After surgical preparation from T8 to S2, the study was divided in two parts: part one to evaluate safety and accuracy of percutaneous \u201cend-on\u201d fluoroscopic drill hole position technique (EOFG); and part two to determinate the feasibility of thoracolumbar (T13-L1) and lumbosacral (L7-S1) percutaneous cannulated pedicle screw and rod fixation (PC-PSRF). The procedures were performed by one of two experienced ECVN diplomates, and one ECVN neurology resident (inexperienced in spinal fixation surgery). Following post-operative CT imaging, drill-hole safety was established using a modified Zdichavsky classification and optimal placement was compared between surgeons. Drill-hole accuracy was calculated based on the deviation from planned angle and bone purchase, between the two levels of surgeon experience. Data sets were analysed at both univariable and multivariable levels with logistic regression analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No unsafe holes (0\/34) were drilled by experienced surgeons, whereas the inexperienced surgeon drilled 4\/34 (11.8%) unsafe holes. Optimal drill-hole placement was significantly associated with surgeon experience (\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001, OR\u202f=\u202f9.66), whereas cadaver number and spinal region did not reach significance. Drill-hole angle and bone depth deviations were significantly different between experienced and inexperienced surgeons (\n                      <jats:italic>p<\/jats:italic>\n                      \u202f=\u202f0.04 and\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001, respectively). Angle deviations were not significantly different between experience levels by region, whereas mean bone purchase deviations were significantly lower for experienced surgeons in the thoracic region (\n                      <jats:italic>p<\/jats:italic>\n                      \u202f=\u202f0.002), but differences were not significant in the lumbar and sacral regions. The mean time taken to drill the hole was significantly longer for the inexperienced surgeon (\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001). PC-PSRF using EOFG was successfully demonstrated at T13-L1 and L7-S1.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The technique was feasible and allowed for percutaneous fixation of the thoracolumbar and lumbosacral segments. Previous experience in open instrumented spinal surgery is beneficial for safe and accurate application.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical significance<\/jats:title>\n                    <jats:p>The PC-PSRF technique using EOFG guidance warrants future clinical studies to investigation a potential role in reducing pain, hospitalisation length, muscle injury and need for surgical revision.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fvets.2026.1789511","type":"journal-article","created":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T05:22:30Z","timestamp":1773984150000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Minimally invasive percutaneous cannulated polyaxial screw and rod fixation thoracolumbar and lumbosacral vertebrae: cadaveric evaluation of accuracy and safety of a fluoroscopic-guided technique, in large breed dogs"],"prefix":"10.3389","volume":"13","author":[{"given":"Francisca","family":"Couto","sequence":"first","affiliation":[{"name":"Lumbry Park Veterinary Specialists","place":["Alton, United Kingdom"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeremy","family":"Rose","sequence":"additional","affiliation":[{"name":"Lumbry Park Veterinary Specialists","place":["Alton, United Kingdom"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victor","family":"Nores","sequence":"additional","affiliation":[{"name":"AURA Veterinary","place":["Guilford, United Kingdom"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Colin J.","family":"Driver","sequence":"additional","affiliation":[{"name":"Lumbry Park Veterinary Specialists","place":["Alton, United Kingdom"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,3,20]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"O5","DOI":"10.1111\/vsu.13685","article-title":"A review of minimally invasive fracture stabilization in dogs and cats","volume":"50","author":"Pozzi","year":"2021","journal-title":"Vet Surg"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.cvsm.2017.08.008","article-title":"Minimally invasive spine surgery in small animals","volume":"48","author":"Hettlich","year":"2018","journal-title":"Vet Clin North Am Small Anim Pract"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1055\/s-0041-1736219","article-title":"Minimal invasive fluoroscopic percutaneous lateral stabilization of thoracolumbar spinal fractures and luxations using unilateral uniplanar external skeletal fixators in dogs and cats","volume":"35","author":"Bitterli","year":"2022","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1111\/j.1532-950X.2012.00989.x","article-title":"Pedicle screw-rod fixation of the canine lumbosacral junction","volume":"41","author":"Smolders","year":"2012","journal-title":"Vet Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"1208593","DOI":"10.3389\/fvets.2023.1208593","article-title":"Instrumented cervical fusion using patient-specific end-plate conforming interbody devices with a micro-porous structure in nine dogs with disk-associated cervical spondylomyelopathy","volume":"10","author":"Driver","year":"2023","journal-title":"Front Vet Sci"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3171\/spi.2002.97.1.0007","article-title":"Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results","volume":"97","author":"Foley","year":"2002","journal-title":"J Neurosurg"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1097\/BRS.0b013e31823c80d8","article-title":"Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates","volume":"37","author":"Raley","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1055\/s-0042-1750056","article-title":"Accuracy and safety of neuronavigation for minimally invasive stabilization in the thoracolumbar spine using polyaxial screws-rod: a canine cadaveric proof of concept","volume":"35","author":"Guevar","year":"2022","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1419521","DOI":"10.3389\/fvets.2024.1419521","article-title":"Accuracy and safety of freehand vs. end-on fluoroscopic guided drill-hole placement in canine cadaveric thoracic, lumbar and sacral vertebrae","volume":"11","author":"Driver","year":"2024","journal-title":"Front Vet Sci."},{"key":"ref10","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1055\/a-2479-5742","article-title":"First experience using a new minimally invasive screw-rod system for completely percutaneous pedicle screw fixation of the cervical spine","volume":"86","author":"Scholz","year":"2025","journal-title":"J Neurol Surg A Cent Eur Neurosurg"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1097\/00007632-199805010-00021","article-title":"Anatomic considerations of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open-lamina technique","volume":"23","author":"Xu","year":"1998","journal-title":"Spine"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"982560","DOI":"10.3389\/fvets.2022.982560","article-title":"Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs","volume":"9","author":"Goffart","year":"2022","journal-title":"Front Vet Sci"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1111\/j.1748-5827.2006.00070.x","article-title":"Computed tomography study of implantation corridors in canine vertebrae","volume":"47","author":"Watine","year":"2006","journal-title":"J Small Anim Pract"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1007\/s00068-004-1422-9","article-title":"Accuracy of pedicle screw placement in thoracic spine fractures","volume":"30","author":"Zdichavsky","year":"2004","journal-title":"Eur J Trauma"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1007\/s00586-012-2476-8","article-title":"Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures: a prospective trial","volume":"22","author":"Heintel","year":"2013","journal-title":"Eur Spine J"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1016\/j.jocn.2010.09.019","article-title":"Technique, challenges and indications for percutaneous pedicle screw fixation","volume":"18","author":"Mobbs","year":"2011","journal-title":"J Clin Neurosci"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.spinee.2006.02.030","article-title":"Automated intraoperative EMG testing during percutaneous pedicle screw placement","volume":"6","author":"Dickerman","year":"2006","journal-title":"Spine J"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"3053","DOI":"10.1242\/jeb.204.17.3053","article-title":"Epaxial muscle function in trotting dogs","volume":"204","author":"Ritter","year":"2001","journal-title":"J Exp Biol"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1242\/jeb.020248","article-title":"Function of the epaxial muscles during trotting","volume":"212","author":"Schilling","year":"2009","journal-title":"J Exp Biol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1111\/j.1532-950X.2007.00290.x","article-title":"Closed fluoroscopic-assisted spinal arch external skeletal fixation for the stabilization of vertebral column injuries in five dogs","volume":"36","author":"Wheeler","year":"2007","journal-title":"Vet Surg"},{"key":"ref21","article-title":"Use of an external skeletal fixator to correct spinal fracture\/luxation and instability in three dogs","volume":"2","author":"Lanz","year":"2000","journal-title":"Vet Neurol Neurosurg"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1111\/j.1532-950x.2000.00070.x","article-title":"Surgical treatment of lumbosacral instability caused by discospondylitis in four dogs","volume":"29","author":"Auger","year":"2000","journal-title":"Vet Surg"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1111\/j.1748-5827.2008.00582.x","article-title":"Vertebral stabilisation and selective decompression for the management of triple thoracolumbar disc protrusions","volume":"49","author":"McKee","year":"2008","journal-title":"J Small Anim Pract"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1111\/vsu.14311","article-title":"Dynamic magnetic resonance imaging of the lumbosacral spine in neutral and flexed position for presurgical assessment of clinically affected dogs with degenerative lumbosacral stenosis","volume":"55","author":"Baldo Clemot","year":"2025","journal-title":"Vet Surg"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1055\/s-0041-1735647","article-title":"Distraction stabilization of degenerative lumbosacral stenosis: technique and mid- to long-term outcome in 30 cases","volume":"34","author":"Inness","year":"2021","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis","year":"2012","journal-title":"Eur Spine J"}],"container-title":["Frontiers in Veterinary Science"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2026.1789511\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T05:22:32Z","timestamp":1773984152000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fvets.2026.1789511\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,20]]},"references-count":26,"alternative-id":["10.3389\/fvets.2026.1789511"],"URL":"https:\/\/doi.org\/10.3389\/fvets.2026.1789511","relation":{},"ISSN":["2297-1769"],"issn-type":[{"value":"2297-1769","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,20]]},"article-number":"1789511"}}