{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T20:27:30Z","timestamp":1789417650833,"version":"build-2803163510"},"reference-count":70,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006389","name":"Universit\u00e9 de Gen\u00e8ve","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100006389","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["ssph-journal.org"],"crossmark-restriction":true},"short-container-title":["Public Health Rev."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This scoping review examines evidence on ventilation and filtration strategies in schools and their association with respiratory infection incidence and proxy indicators such as CO2, particulate levels, and absenteeism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Following PRISMA-ScR guidelines, we searched PubMed, Embase, and Web of Science (19 March 2025) for studies published between 2020 and 2025 in English, French, or Italian. Eligible designs included interventional, observational, and modelling studies, as well as reviews. Screening and data extraction were performed using Rayyan, and similar publications were verified with LiteRev.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Sixty-two studies met inclusion criteria. Mechanical ventilation, especially with high-efficiency filtration, was associated with lower CO2, fewer airborne particles, and reduced infection incidence or absenteeism. Natural ventilation showed variable effectiveness influenced by climate and window use. Hybrid systems and multilayered approaches provided the greatest reductions in estimated infection risk.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Ventilation and filtration strategies reduce respiratory infection risk in schools. Mechanical and hybrid systems perform more reliably than natural ventilation. Further research should address feasibility, safety, sustainability, and implementation in low-resource settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/phrs.2026.1608923","type":"journal-article","created":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T05:10:06Z","timestamp":1784178606000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Ventilation and filtration strategies to reduce respiratory infections in schools: a scoping review"],"prefix":"10.3389","volume":"47","author":[{"given":"Elisabetta","family":"Erriu","sequence":"first","affiliation":[{"name":"Facult\u00e9 de M\u00e9decine, Institut de Sant\u00e9 Globale, Universit\u00e9 de Gen\u00e8ve","place":["Geneva, Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Hasselgard-Rowe","sequence":"additional","affiliation":[{"name":"Facult\u00e9 de M\u00e9decine, Institut de Sant\u00e9 Globale, Universit\u00e9 de Gen\u00e8ve","place":["Geneva, Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elsa","family":"Gaillard","sequence":"additional","affiliation":[{"name":"Facult\u00e9 de M\u00e9decine, Institut de Sant\u00e9 Globale, Universit\u00e9 de Gen\u00e8ve","place":["Geneva, Switzerland"]},{"name":"Service de Sante de la Jeunesse","place":["Geneva, Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoine","family":"Flahault","sequence":"additional","affiliation":[{"name":"Facult\u00e9 de M\u00e9decine, Institut de Sant\u00e9 Globale, Universit\u00e9 de Gen\u00e8ve","place":["Geneva, Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,16]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"112484","DOI":"10.1016\/j.buildenv.2024.112484","article-title":"Analysis of IAQ in classrooms during COVID-19 pandemic and the effect of window ventilation and air cleaners depending on season","volume":"270","author":"Duill","year":"2025","journal-title":"Building Environ"},{"key":"B2","volume-title":"DANS LES ECOLES FRAN\u00c7AISES-2","year":"2025"},{"key":"B3","doi-asserted-by":"publisher","first-page":"104908","DOI":"10.1016\/j.jobe.2022.104908","article-title":"Indoor air quality and health in schools: a critical review for developing the roadmap for the future school environment","volume":"57","author":"Sadrizadeh","year":"2022","journal-title":"J Building Eng"},{"key":"B4","doi-asserted-by":"publisher","first-page":"121961","DOI":"10.1016\/j.apenergy.2023.121961","article-title":"Assessing school ventilation strategies from the perspective of health, environment, and energy","volume":"353","author":"Pollozhani","year":"2024","journal-title":"Appl Energy"},{"key":"B5","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1007\/s44273-024-00033-0","article-title":"Air quality monitoring device to mitigate the spread of COVID-19 in educational buildings","volume":"18","author":"Quiroga","year":"2024","journal-title":"Asian J Atmos Environ"},{"key":"B6","volume-title":"Directorate General for Health and Consumers., Regional Environmental Centre for Central and Eastern Europe. SINPHONIE: Schools Indoor Pollution and Health Observatory Network in Europe: Final Report","year":"2014"},{"key":"B7","unstructured":"More infections in poorly ventilated classrooms\n          \n          \n          2025"},{"key":"B8","doi-asserted-by":"publisher","first-page":"169","DOI":"10.34172\/hpp.2020.29","article-title":"Indoor air quality at school and students\u2019 performance: recommendations of the UNESCO chair on health education and sustainable development and the Italian society of environmental medicine (SIMA)","volume":"10","author":"Pulimeno","year":"2020","journal-title":"Health Promot Perspect"},{"key":"B9","doi-asserted-by":"publisher","first-page":"7463","DOI":"10.3390\/en14227463","article-title":"Room HVAC influences on the removal of airborne particulate matter: implications for school reopening during the COVID-19 pandemic","volume":"14","author":"Mohammadi Nafchi","year":"2021","journal-title":"Energies"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2769","DOI":"10.3390\/en17112769","article-title":"A new tailored approach to calculate the optimal number of outdoor air changes in school building HVAC systems in the Post-COVID-19 era","volume":"17","author":"D\u2019Agostino","year":"2024","journal-title":"Energies"},{"key":"B11","volume-title":"COVID-19 Infection Risk Assessment in a Kindergarten Utilizing Continuous Air Quality Monitoring Data","author":"Chen","year":"2025"},{"key":"B12","doi-asserted-by":"publisher","first-page":"6549","DOI":"10.3390\/su16156549","article-title":"Indoor environmental quality and effectiveness of portable air cleaners in reducing levels of airborne particles during schools\u2019 reopening in the COVID-19 pandemic","volume":"16","author":"Villanueva","year":"2024","journal-title":"Sustainability"},{"key":"B13","doi-asserted-by":"publisher","first-page":"e0291840","DOI":"10.1371\/journal.pone.0291840","article-title":"Ventilation during COVID-19 in a school for students with intellectual and developmental disabilities (IDD)","volume":"19","author":"Zand","year":"2024","journal-title":"PLoS ONE"},{"key":"B14","doi-asserted-by":"publisher","first-page":"em632","DOI":"10.29333\/ejgm\/15962","article-title":"Quality of indoor air in educational institutions and adverse public health in Europe: a scoping review","volume":"22","author":"Adamopoulos","year":"2025","journal-title":"ELECTRON J GEN MED"},{"key":"B15","doi-asserted-by":"publisher","first-page":"e072284","DOI":"10.1136\/bmjopen-2023-072284","article-title":"Effect of portable HEPA filters on COVID-19 period prevalence: an observational quasi-interventional study in German kindergartens","volume":"13","author":"Falkenberg","year":"2023","journal-title":"BMJ Open"},{"key":"B16","doi-asserted-by":"publisher","first-page":"ofae169","DOI":"10.1093\/ofid\/ofae169","article-title":"Air cleaners and respiratory infections in schools: a modeling study based on epidemiologic, environmental, and molecular data","volume":"11","author":"Banholzer","year":"2024","journal-title":"Open Forum Infect Dis"},{"key":"B17","doi-asserted-by":"publisher","first-page":"449","DOI":"10.29063\/ajrh2024\/v28i10s.46","article-title":"Ventilation in school and students\u2019 health after outbreak of COVID-19: a systematic literature review","volume":"28","author":"Moelyaningrum","year":"2024","journal-title":"AJRH"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1608923","DOI":"10.3389\/phrs.2023.1605803","article-title":"Indoor air quality and COVID-19: a scoping review","volume":"45","author":"Braggion","year":"2024","journal-title":"Public Health Rev"},{"key":"B19","doi-asserted-by":"publisher","first-page":"8851685","DOI":"10.1155\/2021\/8851685","article-title":"A systematic review on indoor environmental quality in naturally ventilated school classrooms: a way forward","volume":"2021","author":"Kapoor","year":"2021","journal-title":"Adv Civil Eng"},{"key":"B20","doi-asserted-by":"publisher","first-page":"110882","DOI":"10.1016\/j.enbuild.2021.110882","article-title":"High energy efficiency ventilation to limit COVID-19 contagion in school environments","volume":"240","author":"Schibuola","year":"2021","journal-title":"Energy and Buildings"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1111\/ina.12818","article-title":"Seasonal variation in airborne infection risk in schools due to changes in ventilation inferred from monitored carbon dioxide","volume":"31","author":"Vouriot","year":"2021","journal-title":"Indoor Air"},{"key":"B22","doi-asserted-by":"publisher","first-page":"110805","DOI":"10.1016\/j.envres.2021.110805","article-title":"Estimating aerosol transmission risk of SARS-CoV-2 in New York city public schools during reopening","volume":"195","author":"Pavilonis","year":"2021","journal-title":"Environ Res"},{"key":"B23","doi-asserted-by":"publisher","first-page":"107926","DOI":"10.1016\/j.buildenv.2021.107926","article-title":"A systematic approach to estimating the effectiveness of multi-scale IAQ strategies for reducing the risk of airborne infection of SARS-CoV-2","volume":"200","author":"Shen","year":"2021","journal-title":"Building Environ"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1080\/23744731.2021.1977693","article-title":"Airborne transmission of SARS-CoV-2 in indoor environments: a comprehensive review","volume":"27","author":"Shen","year":"2021","journal-title":"Sci Technology Built Environ"},{"key":"B25","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1186\/s12879-020-05200-6","article-title":"Estimating the nationwide transmission risk of measles in US schools and impacts of vaccination and supplemental infection control strategies","volume":"20","author":"Azimi","year":"2020","journal-title":"BMC Infect Dis"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1087087","DOI":"10.3389\/fpubh.2022.1087087\/full","article-title":"Increasing ventilation reduces SARS-CoV-2 airborne transmission in schools: a retrospective cohort study in Italy\u2019s Marche region","volume":"10","author":"Buonanno","year":"2022","journal-title":"Front Public Health"},{"key":"B27","doi-asserted-by":"publisher","first-page":"210232","DOI":"10.4209\/aaqr.210232","article-title":"Study on droplet dispersion influenced by ventilation and source configuration in classroom settings using low-cost sensor network","volume":"21","author":"Chen","year":"2021","journal-title":"Aerosol Air Qual Res"},{"key":"B28","doi-asserted-by":"publisher","first-page":"107944","DOI":"10.1016\/j.envint.2023.107944","article-title":"Associations between illness-related absences and ventilation and indoor PM2.5 in elementary schools of the midwestern United States","volume":"176","author":"Deng","year":"2023","journal-title":"Environ Int"},{"key":"B29","doi-asserted-by":"publisher","first-page":"106044","DOI":"10.1016\/j.jobe.2023.106044","article-title":"The impact of retrofitted ventilation approaches on long-range airborne infection risk for lecture room environments: design stage methodology and application","volume":"68","author":"O\u2019 Donovan","year":"2023","journal-title":"J Building Eng"},{"key":"B30","article-title":"Energy performance and infection risk evaluation of retrofitted ventilation systems in times of COVID","volume-title":"Paper Presented at 9th Conference of IBPSA-germany and Austria","author":"Pollozhani","year":"2022"},{"key":"B31","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.3390\/buildings13071743","article-title":"Window opening or mechanical ventilation systems for Italian schools? Energetic aspects, CO2 concentration and infection risk assessment based on the SARS-CoV-2 data","volume":"13","author":"Busato","year":"2023","journal-title":"Buildings"},{"key":"B32","doi-asserted-by":"publisher","first-page":"pgad429","DOI":"10.1093\/pnasnexus\/pgad429\/7485353","article-title":"The effect of post-COVID-19 ventilation measures on indoor air quality in primary schools","volume":"3","author":"Eichholtz","year":"2023","journal-title":"PNAS Nexus"},{"key":"B33","doi-asserted-by":"publisher","first-page":"109717","DOI":"10.1016\/j.buildenv.2022.109717","article-title":"Assessment of indoor air quality and risk of COVID-19 infection in Spanish secondary school and university classrooms","volume":"226","author":"Rodr\u00edguez","year":"2022","journal-title":"Building Environ"},{"key":"B34","doi-asserted-by":"publisher","first-page":"3746","DOI":"10.3390\/ijerph20043746","article-title":"The influence of ventilation measures on the airborne risk of infection in schools: a scoping review","volume":"20","author":"Jendrossek","year":"2023","journal-title":"Int J Environ Res Public Health"},{"key":"B35","doi-asserted-by":"publisher","first-page":"10792","DOI":"10.3390\/su162310792","article-title":"Effect of infectious disease risk management on indoor environmental quality in lecture rooms: current performance and future considerations","volume":"16","author":"O\u2019Donovan","year":"2024","journal-title":"Sustainability"},{"key":"B36","doi-asserted-by":"publisher","first-page":"115487","DOI":"10.1016\/j.ecoenv.2023.115487","article-title":"Efficient trapping and destruction of SARS-CoV-2 using PECO-assisted molekule air purifiers in the laboratory and real-world settings","volume":"264","author":"Acharya","year":"2023","journal-title":"Ecotoxicology Environ Saf"},{"key":"B37","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1080\/02786826.2022.2147414","article-title":"Long-term filter efficiency of mobile air purifiers in schools","volume":"57","author":"Granzin","year":"2023","journal-title":"Aerosol Sci Technology"},{"key":"B38","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1080\/02786826.2021.1877257","article-title":"Testing mobile air purifiers in a school classroom: reducing the airborne transmission risk for SARS-CoV-2","volume":"55","author":"Curtius","year":"2021","journal-title":"Aerosol Sci Technology"},{"key":"B39","doi-asserted-by":"publisher","first-page":"779","DOI":"10.15585\/mmwr.mm7021e1","article-title":"Mask use and ventilation improvements to reduce COVID-19 incidence in elementary schools \u2014 georgia, November 16\u2013December 11, 2020","volume":"70","author":"Gettings","year":"2021","journal-title":"MMWR Morb Mortal Wkly Rep"},{"key":"B40","doi-asserted-by":"publisher","first-page":"103188","DOI":"10.1016\/j.scs.2021.103188","article-title":"Airborne infection risks of SARS-CoV-2 in U.S. schools and impacts of different intervention strategies","volume":"74","author":"Xu","year":"2021","journal-title":"Sustainable Cities Soc"},{"key":"B41","doi-asserted-by":"publisher","first-page":"104840","DOI":"10.1016\/j.jobe.2022.104840","article-title":"Modeling impacts of ventilation and filtration methods on energy use and airborne disease transmission in classrooms","volume":"57","author":"Pistochini","year":"2022","journal-title":"J Building Eng"},{"key":"B42","doi-asserted-by":"publisher","first-page":"110636","DOI":"10.1016\/j.buildenv.2023.110636","article-title":"Evaluating the impact of air purifiers and window operation upon indoor air quality - UK nurseries during Covid-19","volume":"243","author":"Zhang","year":"2023","journal-title":"Building Environ"},{"key":"B43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/ijerph2004010001","article-title":"Environmental research and public health","volume":"1","author":"Tchounwou","year":"2004","journal-title":"IJERPH"},{"key":"B44","doi-asserted-by":"publisher","first-page":"6172","DOI":"10.3390\/en14196172","article-title":"Implementation of a ventilation protocol for SARS-CoV-2 in a higher educational centre","volume":"14","author":"Meiss","year":"2021","journal-title":"Energies"},{"key":"B45","doi-asserted-by":"publisher","first-page":"147764","DOI":"10.1016\/j.scitotenv.2021.147764","article-title":"Natural ventilation strategy and related issues to prevent coronavirus disease 2019 (COVID-19) airborne transmission in a school building","volume":"789","author":"Park","year":"2021","journal-title":"Sci The Total Environ"},{"key":"B46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2023\/9977685","article-title":"A monte carlo assessment of the effect of different ventilation strategies to mitigate the COVID-19 contagion risk in educational buildings","volume":"2023","author":"Albertin","year":"2023","journal-title":"Indoor Air"},{"key":"B47","doi-asserted-by":"publisher","first-page":"2699","DOI":"10.3390\/su13052699","article-title":"Effects of the COVID-19 pandemic on indoor air quality and thermal comfort of primary schools in winter in a mediterranean climate","volume":"13","author":"Alonso","year":"2021","journal-title":"Sustainability"},{"key":"B48","doi-asserted-by":"publisher","first-page":"742","DOI":"10.3390\/buildings13030742","article-title":"Assessing indoor air quality and ventilation to limit aerosol dispersion\u2014Literature review","volume":"13","author":"Hobeika","year":"2023","journal-title":"Buildings"},{"key":"B49","doi-asserted-by":"publisher","first-page":"106369","DOI":"10.1016\/j.jobe.2023.106369","article-title":"Assessment of respiratory disease infection risk and natural ventilation intervention countermeasures in teaching spaces: a campus case study","volume":"70","author":"Li","year":"2023","journal-title":"J Building Eng"},{"key":"B50","doi-asserted-by":"publisher","first-page":"110575","DOI":"10.1016\/j.buildenv.2023.110575","article-title":"Ventilation strategy for simultaneous management of indoor particulate matter and airborne transmission risks \u2013 a case study for urban schools in South Korea","volume":"242","author":"Koo","year":"2023","journal-title":"Building Environ"},{"key":"B51","doi-asserted-by":"publisher","first-page":"165113","DOI":"10.1016\/j.scitotenv.2023.165113","article-title":"The effect of natural ventilation on airborne transmission of the COVID-19 virus spread by sneezing in the classroom","volume":"896","author":"Firatoglu","year":"2023","journal-title":"Sci The Total Environ"},{"key":"B52","doi-asserted-by":"publisher","first-page":"108139","DOI":"10.1016\/j.buildenv.2021.108139","article-title":"Mitigating aerosol infection risk in school buildings: the role of natural ventilation, volume, occupancy and CO2 monitoring","volume":"204","author":"Zivelonghi","year":"2021","journal-title":"Building Environ"},{"key":"B53","doi-asserted-by":"publisher","first-page":"111560","DOI":"10.1016\/j.envres.2021.111560","article-title":"CO2 concentration monitoring inside educational buildings as a strategic tool to reduce the risk of Sars-CoV-2 airborne transmission","volume":"202","author":"Di Gilio","year":"2021","journal-title":"Environ Res"},{"key":"B54","doi-asserted-by":"publisher","first-page":"9261","DOI":"10.3390\/app12189261","article-title":"Quantitative assessment of natural ventilation in an elementary school classroom in the context of COVID-19 and its impact in airborne transmission","volume":"12","author":"Vignolo","year":"2022","journal-title":"Appl Sci"},{"key":"B55","doi-asserted-by":"publisher","first-page":"e19120","DOI":"10.1016\/j.heliyon.2023.e19120","article-title":"Air change rates and infection risk in school environments: monitoring naturally ventilated classrooms in a northern Italian urban context","volume":"9","author":"Ferrari","year":"2023","journal-title":"Heliyon"},{"key":"B56","doi-asserted-by":"publisher","first-page":"e18271","DOI":"10.1016\/j.heliyon.2023.e18271","article-title":"Assessment of natural ventilation strategy to decrease the risk of COVID 19 infection at a rural elementary school","volume":"9","author":"Rey-Hern\u00e1ndez","year":"2023","journal-title":"Heliyon"},{"key":"B57","doi-asserted-by":"publisher","first-page":"104204","DOI":"10.1016\/j.jobe.2022.104204","article-title":"Assessment of ventilation rates inside educational buildings in Southwestern Europe: analysis of implemented strategic measures","volume":"51","author":"Aguilar","year":"2022","journal-title":"J Building Eng"},{"key":"B58","doi-asserted-by":"publisher","first-page":"109922","DOI":"10.1016\/j.buildenv.2022.109922","article-title":"Ventilation and thermal conditions in secondary schools in the Netherlands: effects of COVID-19 pandemic control and prevention measures","volume":"229","author":"Ding","year":"2023","journal-title":"Building Environ"},{"key":"B59","doi-asserted-by":"publisher","first-page":"111092","DOI":"10.1016\/j.envres.2021.111092","article-title":"Assessment of CO2 and aerosol (PM2.5, PM10, UFP) concentrations during the reopening of schools in the COVID-19 pandemic: the case of a metropolitan area in central-southern Spain","volume":"197","author":"Villanueva","year":"2021","journal-title":"Environ Res"},{"key":"B60","doi-asserted-by":"publisher","first-page":"8446","DOI":"10.3390\/su13158446","article-title":"Indoor air quality in naturally ventilated classrooms. Lessons learned from a case study in a COVID-19 scenario","volume":"13","author":"Meiss","year":"2021","journal-title":"Sustainability"},{"key":"B61","volume-title":"COVID-19 Mitigation in a K-12 School Setting: A Case Study of Avenues: The World School","author":"Iyengar","year":"2025"},{"key":"B62","doi-asserted-by":"publisher","first-page":"108042","DOI":"10.1016\/j.buildenv.2021.108042","article-title":"Ventilation procedures to minimize the airborne transmission of viruses in classrooms","volume":"202","author":"Stabile","year":"2021","journal-title":"Building Environ"},{"key":"B63","doi-asserted-by":"publisher","first-page":"w30178","DOI":"10.4414\/smw.2022.w30178","article-title":"SARS-CoV-2 aerosol transmission in schools: the effectiveness of different interventions","volume":"152","author":"Villers","year":"2022","journal-title":"Swiss Med Wkly"},{"key":"B64","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/17452007.2023.2263519","article-title":"The relationship between ventilation rates in schools and the indoor airborne transmission potential of COVID-19","author":"Harrington","year":"2023","journal-title":"Architectural Eng Des Management"},{"key":"B65","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1080\/00038628.2022.2080637","article-title":"Monitoring CO2 concentration to control the infection probability due to airborne transmission in naturally ventilated university classrooms","volume":"65","author":"Fantozzi","year":"2022","journal-title":"Architectural Sci Rev"},{"key":"B66","doi-asserted-by":"publisher","first-page":"e13142","DOI":"10.1111\/ina.13142","article-title":"A multi\u2010layered strategy for COVID \u201019 infection prophylaxis in schools: a review of the evidence for masks, distancing, and ventilation","volume":"32","author":"McLeod","year":"2022","journal-title":"Indoor Air"},{"key":"B67","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1016\/j.jiph.2023.05.011","article-title":"CO2 concentration as an indicator of indoor ventilation performance to control airborne transmission of SARS-CoV-2","volume":"16","author":"Park","year":"2023","journal-title":"J Infect Public Health"},{"key":"B68","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1080\/09613218.2023.2185584","article-title":"Airborne infection risk in classrooms based on environment and occupant behavior measurement under COVID-19 epidemic","volume":"51","author":"Wei","year":"2023","journal-title":"Building Res and Inf"},{"key":"B69","volume-title":"Improving Indoor Air Quality in Schools: Evidence from an Air Purifier Intervention with low-cost Sensors","author":"Renna","year":"2025"},{"key":"B70","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jhin.2021.09.012","article-title":"Effectiveness of portable air filtration on reducing indoor aerosol transmission: preclinical observational trials","volume":"119","author":"Lee","year":"2022","journal-title":"J Hosp Infect"}],"container-title":["Public Health Reviews"],"original-title":[],"link":[{"URL":"https:\/\/www.ssph-journal.org\/articles\/10.3389\/phrs.2026.1608923\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T08:57:25Z","timestamp":1786352245000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ssph-journal.org\/articles\/10.3389\/phrs.2026.1608923\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,16]]},"references-count":70,"alternative-id":["10.3389\/phrs.2026.1608923"],"URL":"https:\/\/doi.org\/10.3389\/phrs.2026.1608923","relation":{},"ISSN":["2107-6952"],"issn-type":[{"value":"2107-6952","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,16]]},"article-number":"1608923"}}