{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:04:21Z","timestamp":1760241861491,"version":"build-2065373602"},"reference-count":47,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2018,10,11]],"date-time":"2018-10-11T00:00:00Z","timestamp":1539216000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2017R1C1B5018287","NRF-2017M2A2A6A02070522"],"award-info":[{"award-number":["NRF-2017R1C1B5018287","NRF-2017M2A2A6A02070522"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Algorithms"],"abstract":"<jats:p>In this paper we propose a novel method for tracking the respiratory phase and 3D tumor position in real time during treatment. The method uses planning four-dimensional (4D) computed tomography (CT) obtained through the respiratory phase, and a kV projection taken during treatment. First, digitally rendered radiographs (DRRs) are generated from the 4DCT, and the structural similarity (SSIM) between the DRRs and the kV projection is computed to determine the current respiratory phase and magnitude. The 3D position of the tumor corresponding to the phase and magnitude is estimated using non-rigid registration by utilizing the tumor path segmented in the 4DCT. This method is evaluated using data from six patients with lung cancer and dynamic diaphragm phantom data. The method performs well irrespective of the gantry angle used, i.e., a respiration phase tracking accuracy of 97.2 \u00b1 2.5%, and tumor tracking error in 3D of 0.9 \u00b1 0.4 mm. The phantom study reveals that the DRRs match the actual projections well. The time taken to track the tumor is 400 \u00b1 53 ms. This study demonstrated the feasibility of a technique used to track the respiratory phase and 3D tumor position in real time using kV fluoroscopy acquired from arbitrary angles around the freely breathing patient.<\/jats:p>","DOI":"10.3390\/a11100155","type":"journal-article","created":{"date-parts":[[2018,10,12]],"date-time":"2018-10-12T02:58:04Z","timestamp":1539313084000},"page":"155","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Real-Time Tumor Motion Tracking in 3D Using Planning 4D CT Images during Image-Guided Radiation Therapy"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9273-034X","authenticated-orcid":false,"given":"Jang-Hwan","family":"Choi","sequence":"first","affiliation":[{"name":"Division of Mechanical and Biomedical Engineering, College of Engineering, Ewha Womans University, Seoul 03760, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sooyeul","family":"Lee","sequence":"additional","affiliation":[{"name":"Bio-Medical IT Convergence Research Department, Electronics and Telecommunications Research Institute, Daejeon 34129, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,10,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.ijrobp.2004.05.007","article-title":"High-tech will improve radiotherapy of NSCLC: A hypothesis waiting to be validated","volume":"60","author":"Ling","year":"2004","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/S0167-8140(01)00349-8","article-title":"The effect of breathing and set-up errors on the cumulative dose to a lung tumor","volume":"60","author":"Engelsman","year":"2001","journal-title":"Radiother. Oncol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1118\/1.1639993","article-title":"4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT","volume":"31","author":"Pan","year":"2004","journal-title":"Med. Phys."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"4821","DOI":"10.1088\/0031-9155\/54\/15\/012","article-title":"4D CT sorting based on patient internal anatomy","volume":"54","author":"Li","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.3109\/0284186X.2013.814152","article-title":"Real-time 2D\/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy","volume":"52","author":"Furtado","year":"2013","journal-title":"Acta. Oncol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/j.radonc.2011.07.031","article-title":"Monitoring tumor motion by real time 2D\/3D registration during radiotherapy","volume":"102","author":"Gendrin","year":"2012","journal-title":"Radiother. Oncol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/S0360-3016(01)01516-4","article-title":"The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: Reduction of respiratory tumor movement and evaluation of the daily setup accuracy","volume":"50","author":"Negoro","year":"2001","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.canrad.2006.07.017","article-title":"Comparative study and clinical implementation of two breathing-adapted radiotherapy techniques: Dosimetric benefits for lung cancer treatment","volume":"10","author":"Simon","year":"2006","journal-title":"Cancer Radiother."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1118\/1.1869852","article-title":"Four-dimensional computed tomography: Image formation and clinical protocol","volume":"32","author":"Rietzel","year":"2005","journal-title":"Med. Phys."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1118\/1.2147743","article-title":"Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system","volume":"33","author":"Li","year":"2006","journal-title":"Med. Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1148\/radiol.10090890","article-title":"A simple respiratory indicator for irradiation during voluntary breath holding: A one-touch device without electronic materials","volume":"255","author":"Onishi","year":"2010","journal-title":"Radiology"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.radonc.2009.03.016","article-title":"Assessment of two novel ventilatory surrogates for use in the delivery of gated\/tracked radiotherapy for non-small cell lung cancer","volume":"91","author":"Hughes","year":"2009","journal-title":"Radiother. Oncol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2837","DOI":"10.1088\/0031-9155\/53\/11\/006","article-title":"A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring","volume":"53","author":"Cho","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Rong, Y., Walston, S., Welliver, M.X., Chakravarti, A., and Quick, A.M. (2014). Improving intra-fractional target position accuracy using a 3D surface surrogate for left breast irradiation using the respiratory-gated deep-inspiration breath-hold technique. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0097933"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1088\/0031-9155\/56\/5\/011","article-title":"Statistical analysis of target motion in gated lung stereotactic body radiation therapy","volume":"56","author":"Zhao","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"ref_16","unstructured":"Anderson, M.M. (2013). Investigating the robustness of the Anzai respiratory gating system. [Master\u2019s Thesis, University of Canterbury]."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/S0360-3016(03)00076-2","article-title":"Feasibility of insertion\/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy","volume":"56","author":"Shirato","year":"2003","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.ijrobp.2004.04.028","article-title":"Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy","volume":"60","author":"Shirato","year":"2004","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.radonc.2011.02.012","article-title":"An evaluation of intrafraction motion of the prostate in the prone and supine positions using electromagnetic tracking","volume":"99","author":"Shah","year":"2011","journal-title":"Radiother. Oncol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.ijrobp.2007.11.054","article-title":"Observations on real-time prostate gland motion using electromagnetic tracking","volume":"71","author":"Langen","year":"2008","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/S0360-3016(00)00625-8","article-title":"Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor","volume":"48","author":"Shirato","year":"2000","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"10826","DOI":"10.1038\/s41598-017-11128-w","article-title":"Target margin design for real-time lung tumor tracking stereotactic body radiation therapy using CyberKnife Xsight Lung Tracking System","volume":"7","author":"Yang","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"5695","DOI":"10.1118\/1.4962932","article-title":"Online 4D ultrasound guidance for real-time motion compensation by MLC tracking","volume":"43","author":"Ipsen","year":"2016","journal-title":"Med. Phys."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"6229","DOI":"10.1088\/0031-9155\/52\/20\/010","article-title":"Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers","volume":"52","author":"Cui","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1088\/0031-9155\/54\/4\/011","article-title":"Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy","volume":"54","author":"Lin","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"5351","DOI":"10.1118\/1.3002323","article-title":"Lung tumor tracking in fluoroscopic video based on optical flow","volume":"35","author":"Xu","year":"2008","journal-title":"Med. Phys."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"5277","DOI":"10.1088\/0031-9155\/52\/17\/012","article-title":"A deformable lung tumor tracking method in fluoroscopic video using active shape models: A feasibility study","volume":"52","author":"Xu","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2505","DOI":"10.1088\/0031-9155\/55\/9\/006","article-title":"Markerless lung tumor tracking and trajectory reconstruction using rotational cone-beam projections: A feasibility study","volume":"55","author":"Lewis","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TIP.2003.819861","article-title":"Image quality assessment: From error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans. Image Process."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","article-title":"A Threshold Selection Method from Gray-Level Histograms","volume":"9","author":"Otsu","year":"1979","journal-title":"IEEE Trans. Syst. Man Cybern."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1850","DOI":"10.1118\/1.1398037","article-title":"Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients","volume":"28","author":"Chen","year":"2001","journal-title":"Med. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1118\/1.2178451","article-title":"A novel respiratory detection method based on automated analysis of ultrasound diaphragm video","volume":"33","author":"Xu","year":"2006","journal-title":"Med. Phys."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1109\/34.121791","article-title":"A method for registration of 3-D shapes","volume":"14","author":"Besl","year":"1992","journal-title":"IEEE Trans. Pattern Anal."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1145\/355744.355745","article-title":"An algorithm for finding best matches in logarithmic expected time","volume":"3","author":"Friedman","year":"1977","journal-title":"ACM Trans. Math. Softw."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"6193","DOI":"10.1088\/0031-9155\/57\/19\/6193","article-title":"Fast simulation of x-ray projections of spline-based surfaces using an append buffer","volume":"57","author":"Maier","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/0020-0190(91)90233-8","article-title":"Computing the minimum Hausdorff distance between two point sets on a line under translation","volume":"38","author":"Rote","year":"1991","journal-title":"Inf. Process. Lett."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.radonc.2007.07.010","article-title":"A feasibility study of image-guided hypofractionated conformal arc therapy for inoperable patients with localized non-small cell lung cancer","volume":"84","author":"Bral","year":"2007","journal-title":"Radiother. Oncol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2868","DOI":"10.1118\/1.2219775","article-title":"Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking","volume":"33","author":"Stock","year":"2006","journal-title":"Med. Phys."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.1016\/j.ijrobp.2005.07.053","article-title":"4D verification of real-time accuracy of the Calypso system with lung cancer patient trajectory data","volume":"63","author":"Parikh","year":"2005","journal-title":"Int. J. Radiat. Oncol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"S195","DOI":"10.1016\/j.ijrobp.2005.07.338","article-title":"Real time prostate translation, rotation, deformation evaluated with Calypso beacon (TM) transponders","volume":"63","author":"Burch","year":"2005","journal-title":"Int. J. Radiat. Oncol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2291020499","article-title":"CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate","volume":"229","author":"Geraghty","year":"2003","journal-title":"Radiology"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/S0003-4975(02)04681-7","article-title":"Stereotactic radiosurgery for lung tumors: Preliminary report of a phase I trial","volume":"75","author":"Whyte","year":"2003","journal-title":"Ann. Thorac. Surg."},{"key":"ref_43","first-page":"CR493","article-title":"CT- guided transthoracic fine needle aspiration of pulmonary lesions: Accuracy and complications in 294 patients","volume":"8","author":"Arslan","year":"2002","journal-title":"Med. Sci. Monit."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/S0360-3016(02)02803-1","article-title":"Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy","volume":"53","author":"Seppenwoolde","year":"2002","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"2923","DOI":"10.1088\/0031-9155\/53\/11\/011","article-title":"Inference of hysteretic respiratory tumor motion from external surrogates: A state augmentation approach","volume":"53","author":"Ruan","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"3623","DOI":"10.1088\/0031-9155\/53\/13\/016","article-title":"An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients","volume":"53","author":"Suh","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.ijrobp.2005.02.010","article-title":"High-dose radiation improved local tumor control and overall survival in patients with inoperable\/unresectable non-small-cell lung cancer: Long-term results of a radiation dose escalation study","volume":"63","author":"Kong","year":"2005","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Algorithms"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1999-4893\/11\/10\/155\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:24:56Z","timestamp":1760196296000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1999-4893\/11\/10\/155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,11]]},"references-count":47,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2018,10]]}},"alternative-id":["a11100155"],"URL":"https:\/\/doi.org\/10.3390\/a11100155","relation":{},"ISSN":["1999-4893"],"issn-type":[{"type":"electronic","value":"1999-4893"}],"subject":[],"published":{"date-parts":[[2018,10,11]]}}}