{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T15:57:46Z","timestamp":1773244666169,"version":"3.50.1"},"reference-count":36,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2010,3,31]],"date-time":"2010-03-31T00:00:00Z","timestamp":1269993600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Algorithms"],"abstract":"<jats:p>The present paper describes a novel recognition method of pulmonary nodules (i.e., cancer candidates) in thoracic computed tomography scans by use of three-dimensional spherical and cylindrical models that represent nodules and blood vessels, respectively. The anatomical validity of these object models and their fidelity to computed tomography scans are evaluated based on the Bayes theorem. The nodule recognition is employed by the maximum a posteriori estimation. The proposed method is applied to 26 actual computed tomography scans, and experimental results are shown.<\/jats:p>","DOI":"10.3390\/a3020125","type":"journal-article","created":{"date-parts":[[2010,3,31]],"date-time":"2010-03-31T11:10:34Z","timestamp":1270033834000},"page":"125-144","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Recognition of Pulmonary Nodules in Thoracic CT Scans Using 3-D Deformable Object Models of Different Classes"],"prefix":"10.3390","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5703-2535","authenticated-orcid":false,"given":"Hotaka","family":"Takizawa","sequence":"first","affiliation":[{"name":"University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinji","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Chukyo University, 101 Kaitsu, Toyota, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsuyoshi","family":"Shiina","sequence":"additional","affiliation":[{"name":"Kyoto University, 53 Sakyo, Kyoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2010,3,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1093\/jnci\/djg040","article-title":"Annual report to the nation on the status of cancer, 1975\u20132000","volume":"95","author":"Weir","year":"2003","journal-title":"J. Natl. Cancer Inst."},{"key":"ref_2","first-page":"832","article-title":"A study of false-negative case in mass-screening of lung cancer","volume":"43","author":"Tanaka","year":"1984","journal-title":"Jay. J. Thor. Med."},{"key":"ref_3","first-page":"271","article-title":"A study of false-negative case in comparative reading of mass-screening of lung cancer","volume":"29","author":"Oda","year":"1989","journal-title":"Lung Cancer"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1002\/scj.4690250207","article-title":"Image processing for computer-aided diagnosis of lung cancer by CT(LSCT)","volume":"25","author":"Yamamoto","year":"1994","journal-title":"Syst. Comp. Japan"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/S0140-6736(99)06093-6","article-title":"Early lung cancer action project: Overall design and findings from baseline screening","volume":"354","author":"Henschke","year":"1999","journal-title":"Lancet"},{"key":"ref_6","first-page":"11","article-title":"Computer-aided diagnosis in thoracic computed tomography","volume":"12","year":"2009","journal-title":"Imaging Decisions MRI"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1109\/TPAMI.1987.4767941","article-title":"Imaging analysis using mathematical morphology","volume":"9","author":"Haralick","year":"1987","journal-title":"IEEE Trans. Pattern Anal. Machine Intell."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Yamamoto, S., Matsumoto, M., Tateno, Y., Iinuma, T., and Matshmoto, T. (1996, January August). Quoit filter: A new filter based on mathematical morphology to extract the isolated shadow, and its application to automatic detection of lung cancer in x-ray CT. Proceedings of the 13th International Conference on Pattern Recognition II, Vienna, Austria.","DOI":"10.1109\/ICPR.1996.546713"},{"key":"ref_9","unstructured":"Okumura, T., Miwa, T., Kako, J., Yamamoto, S., Matsumoto, M., Tateno, Y., Iinuma, T., and Matshmoto, T. (1998, January June). Variable N-Quoit filter applied for automatic detection of lung cancer by X-ray CT. Proceedings of Computer Assisted Radiology and Surgery(CAR\u201998), Tokyo, Japan."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1109\/TMI.2003.817785","article-title":"Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images","volume":"22","author":"Kostis","year":"2003","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1097\/00004424-199404000-00013","article-title":"Computerized detection of pulmonary nodules in CT images","volume":"29","author":"Giger","year":"1994","journal-title":"Invest. Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S1361-8415(98)80009-1","article-title":"Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images","volume":"2","author":"Sato","year":"1998","journal-title":"Med. Image Anal."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Li, Q., and Doi, K. (2004). New selective nodule enhancement filter and its application for significant improvement of nodule detection on computed tomography. Proc. SPIE, 5370.","DOI":"10.1117\/12.535802"},{"key":"ref_14","unstructured":"Kanazawa, K., Niki, N., Nishitani, H., Satoh, H., Ohmatsu, H., and Moriyama, N. (1994, January June). Computer assisted diagnosis of lung cancer using helical X-ray CT. Proceedings of IEEE Workshop on Biomedical Image Analysis, Seattle, Washington, DC, USA."},{"key":"ref_15","unstructured":"McNitt-Gray, M.F., Wyckoff, N., Hart, E.M., Sayre, J.W., Goldin, J.G., and Aberle, D.R. (1999). Computer-Aided Diagnosis in Medical Imaging, Elsevier."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1148\/radiographics.19.5.g99se181303","article-title":"Computerized detection of lung nodules on CT scans","volume":"19","author":"Armato","year":"1999","journal-title":"RadioGraphics"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.acra.2004.02.009","article-title":"Computerized scheme for automated detection of lung nodules in low-dose CT images for lung cancer screening","volume":"11","author":"Arimura","year":"2004","journal-title":"Acad. Radiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/S1076-6332(03)00717-7","article-title":"Mixture distribution analysis of a computer assisted diagnostic method for the evaluation of pulmonary nodules on computed tomography scan","volume":"11","author":"Kung","year":"2004","journal-title":"Acad. Radiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.media.2005.07.001","article-title":"Pulmonary nodule detection in CT images with quantized convergence index filter","volume":"10","author":"Matsumotoa","year":"2006","journal-title":"Med. Image Anal."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.1109\/23.708321","article-title":"Quantitative surface characterization of pulmonary nodules based on thin-section CT images","volume":"45","author":"Kawata","year":"1998","journal-title":"IEEE Trans. Nuclear Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1118\/1.1580485","article-title":"Massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography","volume":"30","author":"Suzuki","year":"2003","journal-title":"Med. Phys."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1109\/TPAMI.2003.1251151","article-title":"Neural Edge Enhancer for Supervised Edge Enhancement from Noisy Images","volume":"25","author":"Suzuki","year":"2003","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1109\/42.932744","article-title":"Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique","volume":"20","author":"Lee","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3348\/kjr.2008.9.1.1","article-title":"Nodule detection in a lung region that\u2019s segmented with using genetic cellular neural networks and 3D template matching with fuzzy rule based thresholding","volume":"9","author":"Ozekes","year":"2008","journal-title":"Korean J. Radiol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Farag, A.A., El-Baz, A., Gimel\u2019farb, G., and Falk, R. (2004, January August). Detection and recognition of lung abnormalities using deformable templates. Proceedings of 17th International Conference on Pattern Recognition, Cambridge, UK.","DOI":"10.1109\/ICPR.2004.1334634"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/S1076-6332(03)00729-3","article-title":"Model-based detection of lung nodules in computed tomography exams","volume":"11","author":"McCulloch","year":"2004","journal-title":"Acad. Radiol."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Ezoe, T., Takizawa, H., Yamamoto, S., Matsumoto, T., Tateno, Y., Iinuma, T., and Matsumoto, M. (2002, January February). Detection method of ground glass opacities from chest X-ray CT images. Proceedings of Society of Photo-Optical Instrumentation Engineers, Medical Imaging 2002, San Diego, CA, USA.","DOI":"10.1117\/12.467137"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1093\/ietisy\/e88-d.6.1273","article-title":"Eigen image recognition of pulmonary nodules from thoracic CT images by use of subspace method","volume":"E88-D-II","author":"Fukano","year":"2005","journal-title":"IEICE Trans. Inf. Syst."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Fukano, G., Takizawa, H., Shigemoto, K., Yamamoto, S., Matsumoto, T., Tateno, Y., Iinuma, T., and Matsumoto, M. (, January July). Recognition method of lung nodules using blood vessel extraction techniques and 3D object models. Proceedings of Society of Photo-Optical Instrumentation Engineers, Medical Imaging 2003, Bellingham, WA, USA.","DOI":"10.1117\/12.480665"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1093\/ietisy\/e90-d.8.1168","article-title":"Accuracy improvement of pulmonary nodule detection based on spatial statistical analysis of thoracic CT scans","volume":"E90-D","author":"Takizawa","year":"2007","journal-title":"IEICE Trans. Inf. Syst."},{"key":"ref_31","unstructured":"Li, H. (1996, January August). A probabilistic disambiguation method based on psycholinguistic. Proceedings of the 4th Workshop on Very Large Corpora, Copenhagen, Denmark."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Li, G., and Huang, T. (1996, January October). An improved training algorithm in HMM-based speech recognition. Proceedings of the 4th International Conference on Spoken Language Processing, Philadelphia, PA, USA.","DOI":"10.21437\/ICSLP.1996-278"},{"key":"ref_33","unstructured":"Press, W.H., Flannery, B.P., Teukolsky, S.A., and Vetterling, W.T. (1988). Numerical Recipes in C, Cambridge University Press."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1016\/j.patrec.2005.10.010","article-title":"An introduction to ROC analysis","volume":"27","author":"Fawcett","year":"2006","journal-title":"Pattern Rec. Lett."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Shigemoto, K., Takizawa, H., Yamamoto, S., Matsumoto, T., Tateno, Y., Iinuma, T., and Matsumoto, M. (2002, January June). An efficient recognition of lung nodules from X-ray CT images using 3D object models. Proceedings of the 16th International Congress and Exhibition, Computer Assisted Radiology and Surgery (CARS2002), Paris, France.","DOI":"10.1007\/978-3-642-56168-9_120"},{"key":"ref_36","unstructured":"Oja, E. (1983). Subspace Methods of Pattern Recognition, Research Studies Press."}],"container-title":["Algorithms"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1999-4893\/3\/2\/125\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:01:59Z","timestamp":1760220119000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1999-4893\/3\/2\/125"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,3,31]]},"references-count":36,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2010,6]]}},"alternative-id":["a3020125"],"URL":"https:\/\/doi.org\/10.3390\/a3020125","relation":{},"ISSN":["1999-4893"],"issn-type":[{"value":"1999-4893","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3,31]]}}}