{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T02:45:51Z","timestamp":1774579551046,"version":"3.50.1"},"reference-count":29,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2018,12,21]],"date-time":"2018-12-21T00:00:00Z","timestamp":1545350400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Special Account Research Funds of the National Technical University of Athens","award":["No number"],"award-info":[{"award-number":["No number"]}]},{"DOI":"10.13039\/501100002752","name":"Bodossaki Foundation","doi-asserted-by":"publisher","award":["No number"],"award-info":[{"award-number":["No number"]}],"id":[{"id":"10.13039\/501100002752","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computation"],"abstract":"<jats:p>Energy consumption in the building sector is responsible for a very large amount of electricity consumption worldwide. The reduction of this consumption is a crucial issue in order to achieve sustainability. The objective of this work is to investigate the use of phase change materials (PCMs) in the building walls in order to reduce the heating and the cooling loads. The novelty of this work is based on the investigation of different scenarios about the position of the PCM layer in the south and the north walls. PCMs can improve the thermal performance and the thermal comfort of a building due to their ability to store large amounts of thermal energy in latent form and so to reduce the temperature fluctuations of the structural components, keeping them within the desired temperature levels. More specifically, this work presents and compares the heating loads, the cooling loads and the temperature distribution of a building in Athens (Greece), with and without PCMs in different positions in the south wall and in the north walls. The simulation is performed with the commercial software TRNSYS 17, using the TRNSYS component: type 1270 (PCM Wall). The results proved that the maximum energy savings per year were achieved by the combination of the insulation and the PCM layer in the north and south walls. More specifically, the reductions in the heating and the cooling loads were found to be 1.54% and 5.90%, respectively. Furthermore, the temperature distribution with the use of a PCM layer is the most acceptable, especially during the summer period.<\/jats:p>","DOI":"10.3390\/computation7010002","type":"journal-article","created":{"date-parts":[[2018,12,21]],"date-time":"2018-12-21T09:24:11Z","timestamp":1545384251000},"page":"2","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Thermal Behavior of a Building with Incorporated Phase Change Materials in the South and the North Wall"],"prefix":"10.3390","volume":"7","author":[{"given":"Maria T.","family":"Plytaria","sequence":"first","affiliation":[{"name":"Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15773 Zografou, Greece"}]},{"given":"Christos","family":"Tzivanidis","sequence":"additional","affiliation":[{"name":"Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15773 Zografou, Greece"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5876-6549","authenticated-orcid":false,"given":"Evangelos","family":"Bellos","sequence":"additional","affiliation":[{"name":"Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15773 Zografou, Greece"}]},{"given":"Ioannis","family":"Alexopoulos","sequence":"additional","affiliation":[{"name":"Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15773 Zografou, Greece"}]},{"given":"Kimon A.","family":"Antonopoulos","sequence":"additional","affiliation":[{"name":"Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15773 Zografou, Greece"}]}],"member":"1968","published-online":{"date-parts":[[2018,12,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Soleimani, Z., Calautit, J.K., and Hughes, B.R. (2016). Computational Analysis of Natural Ventilation Flows in Geodesic Dome Building in Hot Climates. Computation, 4.","DOI":"10.3390\/computation4030031"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.enconman.2016.05.004","article-title":"Energetic and financial evaluation of solar assisted heat pump space heating systems","volume":"120","author":"Bellos","year":"2016","journal-title":"Energy Convers. Manag."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.solener.2013.02.001","article-title":"Cost of PV electricity\u2014Case study of Greece","volume":"91","author":"Fantidis","year":"2013","journal-title":"Sol. Energy"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/0038-092X(85)90105-7","article-title":"Solar radiation correlations for the Athens, Greece","volume":"35","author":"Kouremenos","year":"1985","journal-title":"Sol. Energy"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"102","DOI":"10.15344\/2455-7412\/2015\/102","article-title":"Solar Energy Management Using Phase Change Materials Passive Systems in the Athens Area Buildings","volume":"1","author":"Kravvaritis","year":"2015","journal-title":"Int. J. Mech. Syst. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.enbuild.2012.10.030","article-title":"A new design of metal-sheet cool roof using PCM","volume":"57","author":"Chou","year":"2013","journal-title":"Energy Build."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/j.applthermaleng.2016.04.056","article-title":"Numerical analysis for the optimal location of a thin PCM layer in frame wall","volume":"103","author":"Jin","year":"2016","journal-title":"Appl. Therm. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.applthermaleng.2012.05.017","article-title":"Treatment of natural stone with phase change materials: Experiments and computational approaches","volume":"48","author":"Stamatiadou","year":"2012","journal-title":"Appl. Therm. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2038","DOI":"10.1016\/j.apenergy.2009.01.004","article-title":"Experimental assessment of a phase change material for wall building use","volume":"86","author":"Kuznic","year":"2009","journal-title":"Appl. Energy"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.energy.2007.11.003","article-title":"On the heat transfer rate reduction of structural insulated panels outfitted with phase change materials","volume":"33","author":"Medina","year":"2013","journal-title":"Energy"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.rser.2013.01.024","article-title":"Modeling phase change materials embedded in building enclosure: A review","volume":"21","author":"Zhai","year":"2013","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1796","DOI":"10.1016\/j.applthermaleng.2004.11.001","article-title":"An approach to the simulation of PCMs in building applications using TRNSYS","volume":"25","author":"Ibanez","year":"2005","journal-title":"Appl. Therm. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/j.enbuild.2005.11.002","article-title":"Thermal testing and numerical simulation of a prototype cell using light wallboards coupling vacuum isolation panels and phase change material","volume":"38","author":"Ahmad","year":"2006","journal-title":"Energy Build."},{"key":"ref_14","unstructured":"Schranzhofer, H., Puschnig, P., Heinz, A., and Streicher, W. (June, January 31). Validation of TRNSYS simulation model for PCM energy storages and PCM wall construction elements. Proceedings of the ECOSTOCK 2006-10th International Conference on Thermal Energy Storage, Atlantic City, NJ, USA."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1016\/j.enbuild.2010.01.012","article-title":"Development and validation of a new TRNSYS type for the simulation of external building walls containing PCM","volume":"42","author":"Kuznik","year":"2010","journal-title":"Energy Build."},{"key":"ref_16","unstructured":"Dentel, A., and Stephan, W. (2013). TRNSYS TYPE 399\u2014Phase Change Materials in Passive and Active Wall Constructions, Institute for Energy and Building, Georg Simon Ohm University of Applied Sciences."},{"key":"ref_17","unstructured":"Al-Saadi, S.N., and Zhai, Z.J. (2014). TRNSYS Type 285\u2014Phase Change Materials Embedded in Wall System, Department of Civil, Environmental and Architectural Engineering, University of Colorado."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1080\/19401493.2017.1280087","article-title":"Development and numerical validation of a new model for walls with phase change materials implemented in TRNSYS","volume":"10","author":"Delcroix","year":"2017","journal-title":"J. Build. Perform. Simul."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.scs.2018.04.036","article-title":"Integration of passive PCM technologies for net-zero energy buildings","volume":"41","author":"Stritih","year":"2018","journal-title":"Sustain. Cities Soc."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.tsep.2017.12.012","article-title":"Summer thermal performances of PCM-integrated insulation layers for light-weight building walls: Effect of orientation and melting point temperature","volume":"6","author":"Fateh","year":"2018","journal-title":"Therm. Sci. Eng. Progr."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.enbuild.2017.02.018","article-title":"Establishment and experimental verification of TRNSYS model for PCM floor coupled with solar water heating system","volume":"140","author":"Lu","year":"2017","journal-title":"Energy Build."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.egypro.2016.12.159","article-title":"Effect of PCM in Improving the Thermal Comfort in Buildings","volume":"107","author":"Derradji","year":"2017","journal-title":"Energy Procedia"},{"key":"ref_23","unstructured":"Thermal Energy System Specialists (TESS) (2012). TESSLibs 3-Mathematical Reference, TRNSYS 17\u2013Volume 5\u2014Multizone Building Manual, Transient System Simulation Program, Solar Energy Laboratory (SEL), University of Wisconsin."},{"key":"ref_24","unstructured":"BioPCM (2019, December 21). Phase Change Energy Solutions Australia. Available online: http:\/\/phasechange.com.au\/."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.applthermaleng.2016.06.004","article-title":"Energetic and financial evaluation of a solar assisted heat pump heating system with other usual heating systems in Athens","volume":"106","author":"Tzivanidis","year":"2016","journal-title":"Appl. Therm. Eng."},{"key":"ref_26","unstructured":"YPEKA (2010). EK407\/B\/9.4.2010, Regulation on Energy Performance in the Building Sector (20701-2\/2010)\u2014KENAK, YPEKA. (In Greek)."},{"key":"ref_27","unstructured":"YPEKA (2010). EK407\/B\/9.4.2010, Regulation on Energy Performance in the Building Sector (20701-1\/2010)\u2014KENAK, YPEKA. (In Greek)."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.renene.2016.05.043","article-title":"Evaluation of the application of Phase Change Materials (PCM) on the envelope of a typical dwelling in the Mediterranean region","volume":"97","author":"Panayiotou","year":"2016","journal-title":"Renew. Energy"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.enbuild.2016.04.007","article-title":"Effects of phase change material roof layers on thermal performance of a residential building in Melbourne and Sydney","volume":"121","author":"Jayalath","year":"2016","journal-title":"Energy Build."}],"container-title":["Computation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-3197\/7\/1\/2\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:35:24Z","timestamp":1760196924000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-3197\/7\/1\/2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,21]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,3]]}},"alternative-id":["computation7010002"],"URL":"https:\/\/doi.org\/10.3390\/computation7010002","relation":{},"ISSN":["2079-3197"],"issn-type":[{"value":"2079-3197","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,21]]}}}