{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:14:47Z","timestamp":1760238887078,"version":"build-2065373602"},"reference-count":18,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2020,8,27]],"date-time":"2020-08-27T00:00:00Z","timestamp":1598486400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computers"],"abstract":"<jats:p>This paper investigates the effect that selected auditory distractions have on the signal of a visual P300 Speller in terms of accuracy, amplitude, latency, user preference, signal morphology, and overall signal quality. In addition, it ensues the development of a hierarchical taxonomy aimed at categorizing distractions in the P300b domain and the effect thereof. This work is part of a larger electroencephalography based project and is based on the P300 speller brain\u2013computer interface (oddball) paradigm and the xDAWN algorithm, with eight to ten healthy subjects, using a non-invasive brain\u2013computer interface based on low-fidelity electroencephalographic (EEG) equipment. Our results suggest that the accuracy was best for the lab condition (LC) at 100%, followed by music at 90% (M90) at 98%, trailed by music at 30% (M30) and music at 60% (M60) equally at 96%, and shadowed by ambient noise (AN) at 92.5%, passive talking (PT) at 90%, and finally by active listening (AL) at 87.5%. The subjects\u2019 preference prodigiously shows that the preferred condition was LC as originally expected, followed by M90, M60, AN, M30, AL, and PT. Statistical analysis between all independent variables shows that we accept our null hypothesis for both the amplitude and latency. This work includes data and comparisons from our previous papers. These additional results should give some insight into the practicability of the aforementioned P300 speller methodology and equipment to be used for real-world applications.<\/jats:p>","DOI":"10.3390\/computers9030068","type":"journal-article","created":{"date-parts":[[2020,8,27]],"date-time":"2020-08-27T08:05:18Z","timestamp":1598515518000},"page":"68","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["The Effect That Auditory Distractions Have on a Visual P300 Speller While Utilizing Low-Cost Off-the-Shelf Equipment"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7808-5871","authenticated-orcid":false,"given":"Patrick","family":"Schembri","sequence":"first","affiliation":[{"name":"Department of Computing and Mathematical Sciences, University of Greenwich, London SE10 9LS, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maruisz","family":"Pelc","sequence":"additional","affiliation":[{"name":"Department of Computing and Mathematical Sciences, University of Greenwich, London SE10 9LS, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jixin","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Computing and Mathematical Sciences, University of Greenwich, London SE10 9LS, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,8,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Schembri, P., Pelc, M., and Ma, J. (2019, January 23\u201327). Comparison between a Passive and Active response task and their effect on the Amplitude and Latency of the P300 component for Visual Stimuli while using Low Fidelity Equipment. Proceedings of the Forty First Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019, Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8857093"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Schembri, P., Pelc, M., and Ma, J. (2019, January 20\u201321). The Effect that an Auditory Distraction with differing levels of Intensity have on a Visual P300 Speller while utilizing Low Fidelity Equipment: Alongside the Development of a Taxonomy. Proceedings of the 7th International Conference on Neurotechnology and Physiological Computing Systems, NEUROPhyCS 2019, Vienna, Austria.","DOI":"10.5220\/0008065200500058"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Schembri, P., Pelc, M., and Ma, J. (2019, January 18\u201320). The Effect that Auxiliary Taxonomized Auditory Distractions have on a P300 Speller while utilising Low Fidelity Equipment. Proceedings of the 11th Computer Science and Electronic Engineering Conference (CEEC 2019), Colchester, UK.","DOI":"10.1109\/CEEC47804.2019.8974315"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.neuroimage.2018.09.012","article-title":"Systematic comparison between a wireless EEG system with dry electrodes and a wired EEG system with wet electrodes","volume":"184","author":"Kam","year":"2019","journal-title":"NeuroImage"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Bradford, C.J., Burke, B., Nguyen, C., Slipher, G.A., Mrozek, R., and Hairston, D.W. (2018, January 18\u201321). Performance of conformable, dry EEG sensors. Proceedings of the 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8513428"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1080\/10447311003781326","article-title":"Evaluation of P300-Based Brain-Computer Interface in Real-World Contexts","volume":"26","author":"Nam","year":"2010","journal-title":"Int. J. Hum.-Comput. Interact."},{"key":"ref_7","first-page":"103","article-title":"Validation and Benchmarking of a Wearable EEG Acquisition Platform for Real-World Applications","volume":"13","author":"Valentin","year":"2019","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"188","DOI":"10.3389\/fnhum.2016.00188","article-title":"Proposing Metrics for Benchmarking Novel EEG Technologies Towards Real-World Measurements","volume":"10","author":"Oliveira","year":"2016","journal-title":"Front. Hum. Neurosci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"46017","DOI":"10.1088\/1741-2560\/13\/4\/046017","article-title":"Mobile EEG on the bike: Disentangling attentional and physical contributions to auditory attention tasks","volume":"13","author":"Zink","year":"2016","journal-title":"J. Neural Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1109\/TBME.2009.2012869","article-title":"xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain\u2013Computer Interface","volume":"56","author":"Rivet","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/0013-4694(75)90263-1","article-title":"Two varieties of long-latency positive waves evoked by unpredictable auditory stimuli in man","volume":"38","author":"Squires","year":"1975","journal-title":"Electroencephalogr. Clin. Neurophysiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1126\/science.150.3700.1187","article-title":"Evoked-Potential Correlates of Stimulus Uncertainty","volume":"150","author":"Sutton","year":"1965","journal-title":"Science"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1109\/THMS.2018.2799525","article-title":"A Novel Three-Dimensional P300 Speller Based on Stereo Visual Stimuli","volume":"48","author":"Qu","year":"2018","journal-title":"IEEE Trans. Hum.-Mach. Syst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1109\/TNSRE.2019.2892967","article-title":"An Online Interactive Paradigm for P300 Brain\u2013Computer Interface Speller","volume":"27","author":"Gu","year":"2019","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/978-3-030-27950-9_6","article-title":"Detection of Artifacts Using a Non-invasive BCI on the Basis of Electroencephalography While Utilizing Low-Cost Off-the-Shelf Equipment","volume":"10057","author":"Schembri","year":"2019","journal-title":"Physiol. Comput. Syst."},{"key":"ref_16","unstructured":"Ogura, C., Koga, Y., and Shimokochi, M. (1995, January 25\u201330). Recent Advances in Event-related Brain Potential Research. Proceedings of the 11th International Conference on Event-related Potentials (EPIC), Okinawa, Japan."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1696","DOI":"10.1109\/TBME.2015.2402252","article-title":"An Adaptive Spatial Filter for User-Independent Single Trial Detection of Event-Related Potentials","volume":"62","author":"Woehrle","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Stern, R.M., Ray, W.J., and Quigley, K.S. (2001). Psychophysiological Recording, Oxford University Press. [2nd ed.].","DOI":"10.1093\/acprof:oso\/9780195113594.001.0001"}],"container-title":["Computers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-431X\/9\/3\/68\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:07:43Z","timestamp":1760177263000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-431X\/9\/3\/68"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,27]]},"references-count":18,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["computers9030068"],"URL":"https:\/\/doi.org\/10.3390\/computers9030068","relation":{},"ISSN":["2073-431X"],"issn-type":[{"type":"electronic","value":"2073-431X"}],"subject":[],"published":{"date-parts":[[2020,8,27]]}}}