{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T08:27:54Z","timestamp":1794472074510,"version":"4.9.1"},"reference-count":26,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2014,8,4]],"date-time":"2014-08-04T00:00:00Z","timestamp":1407110400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Entropy"],"abstract":"<jats:p>The impulse turbo expander (ITE) is employed to replace the throttling valve in the vapor compression refrigeration cycle to improve the system performance. An improved ITE and the corresponding cycle are presented. In the new cycle, the ITE not only acts as an expansion device with work extraction, but also serves as an economizer with vapor injection. An increase of 20% in the isentropic efficiency can be attained for the improved ITE compared with the conventional ITE owing to the reduction of the friction losses of the rotor. The performance of the novel cycle is investigated based on energy and exergy analysis. A correlation of the optimum intermediate pressure in terms of ITE efficiency is developed. The improved ITE cycle increases the exergy efficiency by 1.4%\u20136.1% over the conventional ITE cycle, 4.6%\u20138.3% over the economizer cycle and 7.2%\u201321.6% over the base cycle. Furthermore, the improved ITE cycle is also preferred due to its lower exergy loss.<\/jats:p>","DOI":"10.3390\/e16084392","type":"journal-article","created":{"date-parts":[[2014,8,4]],"date-time":"2014-08-04T08:06:18Z","timestamp":1407139578000},"page":"4392-4407","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Exergy Analysis of a Subcritical Refrigeration Cycle with an Improved Impulse Turbo Expander"],"prefix":"10.3390","volume":"16","author":[{"given":"Zhenying","family":"Zhang","sequence":"first","affiliation":[{"name":"Institute of Architecture and Civil Engineering, Hebei United University, Tangshan 063009, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lili","family":"Tian","sequence":"additional","affiliation":[{"name":"Department of Foreign Languages, Tangshan College, Tangshan 063000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,8,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1016\/j.energy.2004.08.007","article-title":"Exergy analysis of transcritical carbon dioxide refrigeration cycle with an expander","volume":"7","author":"Yang","year":"2005","journal-title":"Energy"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.ijrefrig.2004.08.006","article-title":"Piston-cylinder work producing expansion device in a transcritical carbon dioxide cycle. Part I: Experimental investigation","volume":"28","author":"Baek","year":"2005","journal-title":"Int. J. Refrig"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/j.ijrefrig.2005.08.012","article-title":"Integration of a three-stage expander into a CO2 refrigeration system","volume":"28","author":"Nickl","year":"2005","journal-title":"Int. J. Refrig"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1080\/10789669.2009.10390860","article-title":"A rolling piston-type two-phase expander in the transcritical CO2 cycle","volume":"15","author":"Li","year":"2009","journal-title":"HVAC&R Res"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.applthermaleng.2005.05.011","article-title":"Some design features of CO2 swing piston expander","volume":"26","author":"Guan","year":"2006","journal-title":"Appl. Therm. Eng"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2516","DOI":"10.1016\/j.enconman.2010.05.016","article-title":"Study on expansion power recovery in CO2 trans-critical cycle","volume":"51","author":"Tian","year":"2010","journal-title":"Energy Convers. Manag"},{"key":"ref_7","unstructured":"Yang, J., Zhang, L., and Li, H. (2010, January 12\u201315). Development of a two-cylinder rolling piston CO2 expander. West Lafayette, IN, USA."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1080\/10789669.2009.10390859","article-title":"Performance of Vane-Type CO2 Expander and Characteristics of Transcritical Expansion Process","volume":"15","author":"Fukuta","year":"2009","journal-title":"HVAC&R Res"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.ijrefrig.2010.12.005","article-title":"Improved rotary vane expander for trans-critical CO2 cycle by introducing high-pressure gas into the vane slots","volume":"34","author":"Jia","year":"2011","journal-title":"Int. J. Refrig"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1016\/j.ijrefrig.2011.11.014","article-title":"Simulation study on a novel vane-type expander with internal two-stage expansion process for R-410A refrigeration system","volume":"35","author":"Wang","year":"2012","journal-title":"Int. J. Refrig"},{"key":"ref_11","unstructured":"Huff, H., Radermacher, R., and Preissner, M. (2003, January 17\u201322). Experimental investigation of a scroll expander in carbon dioxide air-conditioning system. Washington, DC, USA."},{"key":"ref_12","unstructured":"Fukuta, M., Yanagisawa, T., and Kosuda, O. (2006, January 17\u201320). Performance of scroll expander for CO2 refrigeration cycle. West Lafayette, IN, USA."},{"key":"ref_13","unstructured":"Kohsokabe, H., Koyama, M., and Tojo, K. (2008, January 14\u201317). Performance characteristics of scroll expander for CO2 refrigeration cycles. West Lafayette, IN, USA."},{"key":"ref_14","unstructured":"Stosic, N., Smith, I.K., and Kovacevic, A. (2002, January 16\u201319). A twin screw combined compressor and expander for CO2 refrigeration systems. West Lafayette, IN, USA."},{"key":"ref_15","unstructured":"Smith, I.K., Stosic, N.R., and Aldis, C.A. (1999, January 13\u201315). Twin screw expanders in large chiller units. London, UK."},{"key":"ref_16","unstructured":"Binneberg, P., Norris, C., and Rinne, F. (2003, January 15\u201317). CO2 expander to improve system efficiency. Scottsdale, AZ, USA."},{"key":"ref_17","unstructured":"Hays, L.G., and Brasz, J.J. (1996, January 23\u201326). Two-phase turbines for compressor energy recovery. Purdue, West Lafayette, IN, USA."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1016\/j.expthermflusci.2008.05.007","article-title":"Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner","volume":"32","author":"Cho","year":"2008","journal-title":"Exp. Therm. Fluid Sci"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1080\/10789669.2009.10390864","article-title":"An experimental study on energy recovery by a pelton-type expander in a domestic refrigeration system","volume":"15","author":"He","year":"2009","journal-title":"HVAC&R Res"},{"key":"ref_20","unstructured":"T\u00f8ndell, E. (2006, January 28\u201331). Impulse expander for CO2. Trondheim, Norway."},{"key":"ref_21","unstructured":"Sakata, H., Nagatomo, S., and Matsuzaka, T. (1984). Turbine for use in refrigeration cycle. (4442682), U.S. Patent."},{"key":"ref_22","unstructured":"Hiwata, A., Lida, N., and Sawai, K. (2003, January 7\u201310). A study of cycle performance improvement with expander-compressor in air-conditioning systems. London, UK."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1016\/j.ijrefrig.2013.03.010","article-title":"Economic analysis of the application of expanders in medium scale air-conditioners with conventional refrigerants, R1234yf and CO2","volume":"36","author":"Subiantoro","year":"2013","journal-title":"Int. J. Refrig"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.applthermaleng.2014.01.055","article-title":"Simulation analysis of a two-rolling piston expander replacing a throttling valve in a refrigeration and heat pump system","volume":"66","author":"Zhao","year":"2014","journal-title":"Appl. Therm. Eng"},{"key":"ref_25","unstructured":"Klein, S., and Alvarado, F. (2013). EES-Engineering Equation Solver 2013, version 9.500, F-Chart Software."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1016\/j.ijthermalsci.2009.01.013","article-title":"Performance analysis and optimization of a new two-stage ejector-expansion transcritical CO2 refrigeration cycle","volume":"48","author":"Yari","year":"2009","journal-title":"Int. J. Therm. Sci"}],"container-title":["Entropy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1099-4300\/16\/8\/4392\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:14:20Z","timestamp":1760217260000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1099-4300\/16\/8\/4392"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8,4]]},"references-count":26,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2014,8]]}},"alternative-id":["e16084392"],"URL":"https:\/\/doi.org\/10.3390\/e16084392","relation":{},"ISSN":["1099-4300"],"issn-type":[{"value":"1099-4300","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,8,4]]}}}