{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:31:00Z","timestamp":1760239860600,"version":"build-2065373602"},"reference-count":29,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2020,12,30]],"date-time":"2020-12-30T00:00:00Z","timestamp":1609286400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Entropy"],"abstract":"<jats:p>The main research objective of this paper was to compare exergy performance of three different heat pump (HP)-based systems and one natural gas (NG)-based system for the production of heating and cooling energy in a single-house dwelling. The study considered systems based on: 1. A NG and auxiliary cooling unit; 2. Solely HP, 3. HP with additional seasonal heat storage (SHS) and a solar thermal collector (STC); 4. HP with SHS, a STC and a grey water (GW) recovery unit. The assessment of exergy efficiencies for each case was based on the transient systems simulation program TRNSYS, which was used for the simulation of energy use for space heating and cooling of the building, sanitary hot water production, and the thermal response of the seasonal heat storage and solar thermal system. The results show that an enormous waste of exergy is observed by the system based on an NG boiler (with annual overall exergy efficiency of 0.11) in comparison to the most efficient systems, based on HP water\u2013water with a seasonal heat storage and solar thermal collector with the efficiency of 0.47. The same system with an added GW unit exhibits lower water temperatures, resulting in the exergy efficiency of 0.43. The other three systems, based on air\u2013, water\u2013, and ground\u2013water HPs, show significantly lower annual source water temperatures (10.9, 11.0, 11.0, respectively) compared to systems with SHS and SHS + GW, with temperatures of 28.8 and 19.3 K, respectively.<\/jats:p>","DOI":"10.3390\/e23010047","type":"journal-article","created":{"date-parts":[[2020,12,30]],"date-time":"2020-12-30T09:35:23Z","timestamp":1609320923000},"page":"47","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Performance and Exergy Analyses of a Solar Assisted Heat Pump with Seasonal Heat Storage and Grey Water Heat Recovery Unit"],"prefix":"10.3390","volume":"23","author":[{"given":"Primo\u017e","family":"Poredo\u0161","sequence":"first","affiliation":[{"name":"Laboratory for Refrigeration and District Energy, Faculty of Mechanical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Boris","family":"Vidrih","sequence":"additional","affiliation":[{"name":"Laboratory for Refrigeration and District Energy, Faculty of Mechanical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alojz","family":"Poredo\u0161","sequence":"additional","affiliation":[{"name":"Slovenian Energy Association, 1000 Ljubljana, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,12,30]]},"reference":[{"key":"ref_1","unstructured":"European Commission (2020, October 19). Communication from the Commission to the European Parliament, the Council, the European Economic and Social Committee and the Committee of the Regions: An EU Strategy on Heating and Cooling. Available online: https:\/\/ec.europa.eu\/transparency\/regdoc\/rep\/1\/2016\/EN\/1-2016-51-EN-F1-1.PDF."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.buildenv.2016.01.025","article-title":"Exergy performance of different space heating systems: A theoretical study","volume":"99","author":"Kazanci","year":"2016","journal-title":"Build. Environ."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.apenergy.2015.07.051","article-title":"Optimal exergy control of building HVAC system","volume":"156","author":"Razmara","year":"2015","journal-title":"Appl. Energy"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/S0015-1882(08)70056-9","article-title":"Wastewater filtration: A future for grey water recycling","volume":"45","author":"Sutherland","year":"2008","journal-title":"Filtr. Sep."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.enbuild.2018.12.042","article-title":"Performance of a demonstration solar PVT assisted heat pump system with cold buffer storage and domestic hot water storage tanks","volume":"188","author":"Dannemand","year":"2019","journal-title":"Energy Build."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Hengel, F., Heschl, C., Inschlag, F., and Klanatsky, P. (2020). System efficiency of pvt collector-driven heat pumps. Int. J. Thermofluids, 5.","DOI":"10.1016\/j.ijft.2020.100034"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.enbuild.2017.03.015","article-title":"Energy and exergy analysis of solar integrated air source heat pump for radiant floor heating without water","volume":"142","author":"Dong","year":"2017","journal-title":"Energy Build."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1016\/j.energy.2016.04.050","article-title":"Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system","volume":"107","author":"Akbulut","year":"2016","journal-title":"Energy"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.applthermaleng.2014.08.006","article-title":"Energy and exergy analyses of an integrated solar heat pump system","volume":"73","author":"Suleman","year":"2014","journal-title":"Appl. Therm. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Naranjo-Mendoza, C., Oyinlola, M.A., Wright, A.J., and Greenough, R.M. (2019). Experimental study of a domestic solar-assisted ground source heat pump with seasonal underground thermal energy storage through shallow boreholes. Appl. Therm. Eng., 162.","DOI":"10.1016\/j.applthermaleng.2019.114218"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.solener.2016.04.029","article-title":"Energy and exergy analyses of a new geothermal\u2013solar energy based system","volume":"134","author":"Ezzat","year":"2016","journal-title":"Sol. Energy"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.apenergy.2009.08.008","article-title":"Shower water heat recovery in high-rise residential buildings of Hong Kong","volume":"87","author":"Wong","year":"2010","journal-title":"Appl. Energy"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.applthermaleng.2012.01.031","article-title":"Feasibility study of a localized residential grey water energy-recovery system","volume":"39","author":"Ni","year":"2012","journal-title":"Appl. Therm. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.enbuild.2012.12.026","article-title":"Efficient drain water heat recovery in horizontal domestic shower drains","volume":"59","author":"McNabola","year":"2013","journal-title":"Energy Build."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.enconman.2013.04.009","article-title":"Exergy analysis and comparison of multi-functional heat pump and conventional heat pump systems","volume":"73","author":"Sun","year":"2013","journal-title":"Energy Convers. Manag."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.applthermaleng.2012.02.036","article-title":"Experimental study of a photovoltaic solar-assisted heat-pump\/heat-pipe system","volume":"40","author":"Fu","year":"2012","journal-title":"Appl. Therm. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1007\/s10973-018-7741-6","article-title":"Performance study on photovoltaic\/thermal solar-assisted heat pump system","volume":"136","author":"Ammar","year":"2019","journal-title":"J. Therm. Anal. Calorim."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Caliskan, H., Hepbasli, A., and Dincer, I. (2011). Exergy Analysis and Sustainability Assessment of a Solar-Ground Based Heat Pump With Thermal Energy Storage. J. Sol. Energy Eng., 133.","DOI":"10.1115\/1.4003040"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.enbuild.2013.03.024","article-title":"Comparative exergoenvironmental analysis and assessment of various residential heating systems","volume":"62","author":"Abusoglu","year":"2013","journal-title":"Energy Build."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1016\/j.apenergy.2008.12.010","article-title":"Energy and exergy analyses of space heating in buildings","volume":"86","author":"Yildiz","year":"2009","journal-title":"Appl. Energy"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.energy.2006.04.007","article-title":"Energy and exergy performance of residential heating systems with separate mechanical ventilation","volume":"32","author":"Zmeureanu","year":"2007","journal-title":"Energy"},{"key":"ref_22","unstructured":"EEN 18599 (2007). 2007: Energy Efficiency of Buildings\u2014Calculation of the Energy Needs, Delivered Energy and Primary Energy for Heating, Cooling, Ventilation, Domestic Hot Water and Lighting, German Institute for Standardisation."},{"key":"ref_23","unstructured":"(2020, October 19). Heat Pump. Available online: https:\/\/kronoterm.com\/en\/."},{"key":"ref_24","unstructured":"(2020, October 19). SAP 2016 Seasonal Efficiency Values for Boilers (All Fuels), Building Research Establishment Ltd. (BRE). Available online: www.ncmpcdb.org.uk\/sap."},{"key":"ref_25","unstructured":"(2020, December 23). CEN\u2014CR 1752 Ventilation for Buildings\u2014Design Criteria for the Indoor Environment. Available online: https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/b1ab2055-b8b7-442f-8d15-06719bf38a69\/cr-1752-1998."},{"key":"ref_26","unstructured":"(2020, December 23). Hidria_kolektorji.pdf. Available online: http:\/\/www.lagoja.si\/pdf\/Hidria_kolektorji.pdf."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Niewitecka, K. (2018). Possibilities of heat energy recovery from greywater systems. E3S Web Conf., 30.","DOI":"10.1051\/e3sconf\/20183003003"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Dincer, I., and Rosen, M.A. (2012). Exergy: Energy, Environment and Sustainable Development, Elsevier Science.","DOI":"10.1016\/B978-0-08-097089-9.00004-8"},{"key":"ref_29","first-page":"23","article-title":"Eksergija goriv","volume":"5","author":"Rant","year":"2017","journal-title":"Strojni\u0161ki Vestn. J. Mech. Eng."}],"container-title":["Entropy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1099-4300\/23\/1\/47\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:48:03Z","timestamp":1760179683000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1099-4300\/23\/1\/47"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,30]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,1]]}},"alternative-id":["e23010047"],"URL":"https:\/\/doi.org\/10.3390\/e23010047","relation":{},"ISSN":["1099-4300"],"issn-type":[{"type":"electronic","value":"1099-4300"}],"subject":[],"published":{"date-parts":[[2020,12,30]]}}}