{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T22:17:29Z","timestamp":1782771449883,"version":"3.54.5"},"reference-count":29,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2021,1,23]],"date-time":"2021-01-23T00:00:00Z","timestamp":1611360000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Entropy"],"abstract":"<jats:p>In automated plants, particularly in the petrochemical, energy, and chemical industries, the combined management of all of the incidents that can produce a catastrophic accident is required. In order to do this, an alarm management methodology can be formulated as a discrete event sequence recognition problem, in which time patterns are used to identify the safe condition of the process, especially in the start-up and shutdown stages. In this paper, a new layer of protection (a Super-Alarm), based on the diagnostic stage to industrial processes is presented. The alarms and actions of the standard operating procedures are considered to be discrete events involved in sequences; the diagnostic stage corresponds to the recognition of the situation when these sequences occur. This provides operators with pertinent information about the normal or abnormal situations induced by the flow of the alarms. Chronicles Based Alarm Management (CBAM) is the methodology used in this document to build the chronicles that will permit us to generate the Super-Alarms; in addition, a case study of the petrochemical sector using CBAM is presented in order to build one chronicle that represents the scenario of an abnormal start-up of an oil transport system. Finally, the scenario\u2019s validation for this case is performed, showing the way in which, a Super-Alarm is generated.<\/jats:p>","DOI":"10.3390\/e23020139","type":"journal-article","created":{"date-parts":[[2021,1,25]],"date-time":"2021-01-25T02:07:00Z","timestamp":1611540420000},"page":"139","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Super-Alarms with Diagnosis Proficiency Used as an Additional Layer of Protection Applied to an Oil Transport System"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3710-1086","authenticated-orcid":false,"given":"John W.","family":"V\u00e1squez","sequence":"first","affiliation":[{"name":"Research Group GPS, Universidad de Investigaci\u00f3n y Desarrollo\u2014UDI, Bucaramanga 680004, Colombia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5946-1395","authenticated-orcid":false,"given":"Gustavo","family":"P\u00e9rez-Zu\u00f1iga","sequence":"additional","affiliation":[{"name":"Departamento de Ingenier\u00eda, Pontificia Universidad Cat\u00f3lica del Per\u00fa\u2014PUCP, Avenida Universitaria 1801, San Miguel, Lima 15088, Peru"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Sotomayor-Moriano","sequence":"additional","affiliation":[{"name":"Departamento de Ingenier\u00eda, Pontificia Universidad Cat\u00f3lica del Per\u00fa\u2014PUCP, Avenida Universitaria 1801, San Miguel, Lima 15088, Peru"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adalberto","family":"Ospino","sequence":"additional","affiliation":[{"name":"Research Group GIOPEN, Universidad de la Costa\u2014CUC, Barranquilla 080014, Colombia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,1,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1109\/TSMCC.2007.900670","article-title":"Toward Real-Time Distributed Intelligent Control: A Survey of Research Themes and Applications","volume":"37","author":"Brennan","year":"2007","journal-title":"IEEE Trans. Syst. Man Cybern."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1109\/TCST.2014.2313352","article-title":"Reconfigurable Coordination of Distributed Discrete Event Control Systems","volume":"23","author":"Zhang","year":"2014","journal-title":"IEEE Trans. Control. Syst. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1109\/TR.1979.5220578","article-title":"Software Failure Modes and Effects Analysis","volume":"28","author":"Reifer","year":"1979","journal-title":"IEEE Trans. Reliab."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.conengprac.2007.05.005","article-title":"Manufacturing Plant Control Challenges and Issues","volume":"15","author":"Morel","year":"2007","journal-title":"Control. Eng. Pract."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/j.ifacol.2016.07.269","article-title":"Causal Analysis for Alarm Flood Reduction","volume":"49","author":"Rodrigo","year":"2016","journal-title":"IFAC-PapersOnLine"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S1474-6670(17)54672-8","article-title":"Alarm and Shutdown Frequencies in Offshore Production","volume":"21","author":"Bodsberg","year":"1988","journal-title":"IFAC Proc. Vol."},{"key":"ref_7","first-page":"31","article-title":"Secuencias De Alarmas Para detecci\u00f3n Y diagn\u00f3stico de fallos","volume":"12","author":"Agudelo","year":"2011","journal-title":"Rev. Colomb. Comput."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"645","DOI":"10.3182\/20090630-4-ES-2003.00107","article-title":"An Introduction to Alarm Analysis and Design","volume":"42","author":"Izadi","year":"2009","journal-title":"IFAC Proc. Vol."},{"key":"ref_9","unstructured":"G\u00f3mez, C.F.A. (2016). Integracion de Tecnicas y Las Secuencias de Alarmas Para la Deteccion y el Diagnostico de Fallos, Universitat Politecnica de Valencia."},{"key":"ref_10","unstructured":"V\u00e1squez Capacho, J.W. (2017, October 01). Chronicle Based Alarm Management. Available online: https:\/\/hal.laas.fr\/Tel-02059631."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1002\/prs.11539","article-title":"The Connection of Peak Alarm Rates to Plant Incidents and What You Can Do to Minimize","volume":"32","author":"Beebe","year":"2012","journal-title":"Process. Saf. Prog."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.jlp.2013.07.008","article-title":"A Dynamic Alarm Management Strategy for Chemical Process Transitions","volume":"30","author":"Zhu","year":"2014","journal-title":"J. Loss Prev. Process. Ind."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"John, V., Jorge, P., Carlos, A., and Jose, J. (2013, January 23\u201325). Analysis of Alarm Management in Startups and Shutdowns for Oil Refining Processes. Proceedings of the 2013 II International Congress of Engineering Mechatronics and Automation (CIIMA), Bogot\u00e1, Colombia.","DOI":"10.1109\/CIIMA.2013.6682784"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.proeng.2014.10.405","article-title":"Layer of Protection Analysis","volume":"84","author":"Willey","year":"2014","journal-title":"Procedia Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.ress.2003.09.017","article-title":"Loss of Safety Assessment and the IEC 61508 Standard","volume":"83","author":"Hokstad","year":"2004","journal-title":"Reliab. Eng. Syst. Saf."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1016\/j.ifacol.2015.09.710","article-title":"The Requirements for a New Layer in the Industrial Safety Systems","volume":"48","year":"2015","journal-title":"IFAC-PapersOnLine"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/j.jlp.2005.12.004","article-title":"Safety Barriers: Definition, Classification, and Performance","volume":"19","author":"Sklet","year":"2006","journal-title":"J. Loss Prev. Process. Ind."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1002\/prs.680180409","article-title":"Layer of Protection Analysis and Inherently Safer Processes","volume":"18","author":"Dowell","year":"1999","journal-title":"Process. Saf. Prog."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.ifacol.2019.09.192","article-title":"New Concept of Safeprocess Based on a Fault Detection Methodology: Super Alarms","volume":"52","author":"Moriano","year":"2019","journal-title":"IFAC-PapersOnLine"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"45","DOI":"10.29047\/01225383.168","article-title":"An additional layer of protection through superalarms with diagnosis capability","volume":"10","year":"2020","journal-title":"CT&F Cienc. Tecnol. Futuro"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"7265","DOI":"10.3182\/20080706-5-KR-1001.01229","article-title":"Hybrid Systems Diagnosis by Coupling Continuous and Discrete Event Techniques","volume":"41","author":"Bayoudh","year":"2008","journal-title":"IFAC Proc. Vol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3757","DOI":"10.1109\/TIE.2015.2417501","article-title":"A Survey of Fault Diagnosis and Fault-Tolerant Techniques\u2014Part I: Fault Diagnosis with Model-Based and Signal-Based Approaches","volume":"62","author":"Gao","year":"2015","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ifacol.2016.07.101","article-title":"Alarm Management Based on Diagnosis","volume":"49","author":"Subias","year":"2016","journal-title":"IFAC-PapersOnLine"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.engappai.2017.07.008","article-title":"Alarm Management via Temporal Pattern Learning","volume":"65","author":"Capacho","year":"2017","journal-title":"Eng. Appl. Artif. Intell."},{"key":"ref_25","unstructured":"V\u00e1squez, J.W., Trav\u00e9-Massuy\u00e8s, L., Subias, A., Jim\u00e9nez, F., and Agudelo, C. (September, January 31). Chronicle Based Alarm Management in Startup and Shutdown stages. Proceedings of the 26th International Workshop on Principles of Diagnosis, Paris, France. Available online: https:\/\/hal.laas.fr\/Hal-01847469."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/S1474-6670(17)37375-5","article-title":"Alarm Driven Monitoring Based on Chronicles","volume":"33","author":"Cordier","year":"2000","journal-title":"IFAC Proc. Vol."},{"key":"ref_27","unstructured":"Dousson, C. (1994). Suivi d\u2019\u00e9volutions Et Reconnaissance De Chroniques. [Ph.D. Thesis, Universit\u00e9 de Toulouse]. Available online: http:\/\/www.theses.fr\/1994TOU30264."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.engappai.2014.09.016","article-title":"Iterative Hybrid Causal Model Based Diagnosis: Application to Automotive Embedded Functions","volume":"37","author":"Pons","year":"2015","journal-title":"Eng. Appl. Artif. Intell."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"101162","DOI":"10.1016\/j.jocs.2020.101162","article-title":"Simultaneous occurrences and false-positives analysis in discrete event dynamic systems","volume":"44","author":"Ospino","year":"2020","journal-title":"J. Comput. Sci."}],"container-title":["Entropy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1099-4300\/23\/2\/139\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:14:20Z","timestamp":1760159660000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1099-4300\/23\/2\/139"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,23]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,2]]}},"alternative-id":["e23020139"],"URL":"https:\/\/doi.org\/10.3390\/e23020139","relation":{},"ISSN":["1099-4300"],"issn-type":[{"value":"1099-4300","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,23]]}}}