{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T05:01:54Z","timestamp":1777006914670,"version":"3.51.4"},"reference-count":32,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T00:00:00Z","timestamp":1776038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Entropy"],"abstract":"<jats:p>Aiming to improve cooling and dehumidification performance in air conditioning systems and to meet the trend toward environmentally friendly refrigerants, this study proposes a coupled system that combines a CO2 transcritical refrigeration cycle (CTRC) with a liquid desiccant dehumidification cycle. The system takes advantage of high-grade waste heat from the exothermic side of the CTRC to drive the regenerating process of the liquid desiccant dehumidification. A cooling evaporator is adopted to cool indoor air, while another evaporator (i.e., Evaporator II) is utilized to cool the concentrated solution, improving dehumidification capacity and enabling independent control of sensible and latent heat loads. Through thermodynamic modeling and the exergy analysis model, a mathematical model of the system is developed to examine how key parameters (such discharge pressure and the CO2 mass flow rate ratio in Evaporator II (\u03bb)) affect performance and to analyze exergy loss features. Results show that the system\u2019s coefficient of performance (COP) and dehumidification coefficient of performance (COPdeh) initially rise and then fall with increasing CTRC discharge pressure, achieving an optimal pressure of around 10,500 kPa (COP up to 4.32) under a specific working condition, surpassing those of standalone CTRC systems. Properly increasing \u03bb enhances dehumidification capacity and energy efficiency, with a low specific dehumidification energy (SDE) of 0.2033 kWh\/kg, indicating high economic efficiency. Most exergy losses occur in the CO2-solution heat exchanger and dehumidifier (over 60% of total losses). The system\u2019s maximum exergy efficiency reaches 12.4%, leaving room for further improvements. This coupled system offers an efficient, eco-friendly way for air conditioning in high-humidity environments, combining cooling and dehumidification with the potential for energy recovery.<\/jats:p>","DOI":"10.3390\/e28040436","type":"journal-article","created":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T10:19:14Z","timestamp":1776075554000},"page":"436","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Theoretical Research of a Transcritical Refrigeration System of CO2 Coupled with Liquid Desiccant Dehumidification Cycle Using Exergy Analysis Method"],"prefix":"10.3390","volume":"28","author":[{"given":"Xiao","family":"Liang","sequence":"first","affiliation":[{"name":"College of Power Engineering, Naval University of Engineering, Wuhan 430033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongbao","family":"Liu","sequence":"additional","affiliation":[{"name":"College of Power Engineering, Naval University of Engineering, Wuhan 430033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiaolian","family":"Feng","sequence":"additional","affiliation":[{"name":"College of Power Engineering, Naval University of Engineering, Wuhan 430033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongsheng","family":"Su","sequence":"additional","affiliation":[{"name":"College of Power Engineering, Naval University of Engineering, Wuhan 430033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanfei","family":"Li","sequence":"additional","affiliation":[{"name":"College of Power Engineering, Naval University of Engineering, Wuhan 430033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,4,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/0140-7007(93)90014-Y","article-title":"A new, efficient and environmentally benign system for car air-conditioning","volume":"16","author":"Lorentzen","year":"1993","journal-title":"Int. J. Refrig."},{"key":"ref_2","unstructured":"Neks\u00e5, P., and Aarlien, R. (1998). Current status on heat pumps with CO2 as working fluid. International Refrigeration and Air Conditioning Conference, Purdue."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/S0140-7007(98)00017-6","article-title":"CO2-heat pump water heater: Characteristics, system design and experimental results","volume":"21","author":"Rekstad","year":"1998","journal-title":"Int. J. Refrig."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"112529","DOI":"10.1016\/j.enconman.2020.112529","article-title":"Progress in ejector-expansion vapor compression refrigeration and heat pump systems","volume":"207","author":"Zhang","year":"2020","journal-title":"Energy Convers. Manag."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1016\/j.simpat.2006.09.004","article-title":"Numerical simulation of combined screw compressor-expander machines for use in high pressure refrigeration systems","volume":"14","author":"Smith","year":"2006","journal-title":"Simul. Model. Pract. Theory"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.applthermaleng.2014.01.055","article-title":"Simulation analysis of a two-rolling piston expander replacing a throttling valve in a refrigeration and heat pump system","volume":"66","author":"Zhao","year":"2014","journal-title":"Appl. Therm. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.energy.2014.11.007","article-title":"Experimental investigation on a turbo expander substituted for throttle valve in the subcritical refrigeration system","volume":"79","author":"Zhang","year":"2015","journal-title":"Energy"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"4309","DOI":"10.3390\/e16084309","article-title":"Effect of Suction Nozzle Pressure Drop on the Performance of an Ejector-Expansion Transcritical CO2 Refrigeration Cycle","volume":"16","author":"Zhang","year":"2014","journal-title":"Entropy"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1016\/j.ijrefrig.2012.04.012","article-title":"Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump","volume":"35","author":"Banasiak","year":"2012","journal-title":"Int. J. Refrig."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ijrefrig.2019.01.027","article-title":"Preliminary study on CO2 transcritical ejector enhanced compressor refrigeration system for independent space cooling and dehumidification","volume":"100","author":"Jin","year":"2019","journal-title":"Int. J. Refrig."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.energy.2017.01.029","article-title":"Thermodynamic performance evaluation of transcritical CO2 refrigeration cycle integrated with thermoelectric subcooler and expander","volume":"122","author":"Dai","year":"2017","journal-title":"Energy"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.enconman.2009.08.024","article-title":"Experimental study on the performance of CO2 residential air-conditioning system with an internal heat exchanger","volume":"51","author":"Tao","year":"2010","journal-title":"Energy Convers. Manag."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1016\/j.egyr.2021.03.023","article-title":"Conventional and advanced exergy analyses of transcritical CO2 ejector refrigeration system equipped with thermoelectric subcooler","volume":"7","author":"Liu","year":"2021","journal-title":"Energy Rep."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"S\u00f6ylemez, E. (2024). Energy and conventional exergy analysis of an integrated transcritical CO2 (R-744) refrigeration system. Energies, 17.","DOI":"10.3390\/en17020479"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1080\/07373930802715674","article-title":"Analysis of CO2 transcritical cycle heat pump dryers","volume":"27","author":"Li","year":"2009","journal-title":"Dry. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1583","DOI":"10.1080\/07373930601030903","article-title":"Transcritical CO2 heat pump dryer: Part 1. Mathematical model and simulation","volume":"24","author":"Sarkar","year":"2006","journal-title":"Dry. Technol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1016\/S1359-4311(01)00002-3","article-title":"Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning","volume":"21","author":"Dai","year":"2001","journal-title":"Appl. Therm. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1016\/j.applthermaleng.2017.11.011","article-title":"Experimental study of a novel subcooling method based on liquid desiccant dehumidification for vapor-compression refrigeration systems","volume":"130","author":"She","year":"2018","journal-title":"Appl. Therm. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.apenergy.2018.10.101","article-title":"Experimental analysis of dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier","volume":"235","author":"Park","year":"2019","journal-title":"Appl. Energy"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.applthermaleng.2016.12.071","article-title":"Thermodynamic analysis of a compression-absorption refrigeration air-conditioning system coupled with liquid desiccant dehumidification","volume":"115","author":"Su","year":"2017","journal-title":"Appl. Therm. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.enbuild.2012.06.002","article-title":"Performance optimization of heat pump driven liquid desiccant dehumidification systems","volume":"52","author":"Zhang","year":"2012","journal-title":"Energy Build."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.enconman.2011.12.023","article-title":"Combination of air-source heat pumps with liquid desiccant dehumidification of air","volume":"57","author":"Zhang","year":"2012","journal-title":"Energy Convers. Manag."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"112447","DOI":"10.1016\/j.enconman.2019.112447","article-title":"Performance of heat pump driven internally cooled liquid desiccant dehumidification system","volume":"205","author":"Liu","year":"2020","journal-title":"Energy Convers. Manag."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.enconman.2010.06.057","article-title":"Mass transfer performance comparison of two commonly used liquid desiccants: LiBr and LiCl aqueous solutions","volume":"52","author":"Liu","year":"2011","journal-title":"Energy Convers. Manag."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.enconman.2006.06.002","article-title":"Heat and mass transfer model of cross flow liquid desiccant air dehumidifier\/regenerator","volume":"48","author":"Liu","year":"2007","journal-title":"Energy Convers. Manag."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.ijthermalsci.2003.09.003","article-title":"Properties of aqueous solutions of lithium and calcium chlorides: Formulations for use in air conditioning equipment design","volume":"43","author":"Conde","year":"2004","journal-title":"Int. J. Therm. Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1080\/0031910021000004883","article-title":"Thermodynamic properties of aqueous solutions of lithium chloride","volume":"40","author":"Chaudhari","year":"2002","journal-title":"Phys. Chem. Liq. Int. J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2221","DOI":"10.1016\/j.enconman.2006.12.009","article-title":"Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier\/regenerator","volume":"48","author":"Liu","year":"2007","journal-title":"Energy Convers. Manag."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.enbuild.2013.11.025","article-title":"Exergy calculation and analysis of a dehumidification system using liquid desiccant","volume":"69","author":"Zhang","year":"2014","journal-title":"Energy Build."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"117891","DOI":"10.1016\/j.energy.2020.117891","article-title":"Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis","volume":"204","author":"Zhang","year":"2020","journal-title":"Energy"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1080\/15435071003795881","article-title":"Exergy analysis of liquid desiccant dehumidification system","volume":"7","author":"Xiong","year":"2010","journal-title":"Int. J. Green Energy"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1063\/1.555991","article-title":"A New Equation of State for Carbon Dioxide Covering the Fluid Region from the Triple-Point Temperature to 1100 K at Pressures up to 800 MPa","volume":"25","author":"Span","year":"1996","journal-title":"J. Phys. Chem. Ref. Data"}],"container-title":["Entropy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1099-4300\/28\/4\/436\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T04:29:45Z","timestamp":1777004985000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1099-4300\/28\/4\/436"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,13]]},"references-count":32,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["e28040436"],"URL":"https:\/\/doi.org\/10.3390\/e28040436","relation":{},"ISSN":["1099-4300"],"issn-type":[{"value":"1099-4300","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,13]]}}}