{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T21:39:18Z","timestamp":1779399558490,"version":"3.53.1"},"reference-count":21,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2019,6,5]],"date-time":"2019-06-05T00:00:00Z","timestamp":1559692800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004829","name":"Department of Science and Technology of Sichuan Province","doi-asserted-by":"publisher","award":["2016JY0084"],"award-info":[{"award-number":["2016JY0084"]}],"id":[{"id":"10.13039\/501100004829","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81570848"],"award-info":[{"award-number":["81570848"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Information"],"abstract":"<jats:p>Accurate estimation of ultrasound Doppler spectrogram envelope is essential for clinical pathological diagnosis of various cardiovascular diseases. However, due to intrinsic spectral broadening in the power spectrum and speckle noise existing in ultrasound images, it is difficult to obtain the accurate maximum velocity. Each of the standard existing methods has their own limitations and does not work well in complicated recordings. This paper proposes a robust automatic spectral envelope estimation method that is more accurate in phantom recordings and various in-vivo recordings than the currently used methods. Comparisons were performed on phantom recordings of the carotid artery with varying noise and additional in-vivo recordings. The accuracy of the proposed method was on average 8% greater than the existing methods. The experimental results demonstrate the wide applicability under different blood conditions and the robustness of the proposed algorithm.<\/jats:p>","DOI":"10.3390\/info10060199","type":"journal-article","created":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T03:38:01Z","timestamp":1559792281000},"page":"199","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["A Robust Automatic Ultrasound Spectral Envelope Estimation"],"prefix":"10.3390","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9056-5333","authenticated-orcid":false,"given":"Jinkai","family":"Li","sequence":"first","affiliation":[{"name":"College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Zhang","sequence":"additional","affiliation":[{"name":"College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Liu","sequence":"additional","affiliation":[{"name":"College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Liu","sequence":"additional","affiliation":[{"name":"College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Yin","sequence":"additional","affiliation":[{"name":"College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong C.","family":"Liu","sequence":"additional","affiliation":[{"name":"College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,6,5]]},"reference":[{"key":"ref_1","first-page":"126","article-title":"Speckle Noise Reduction in Medical Ultrasound Images","volume":"9","author":"Benzarti","year":"2012","journal-title":"Int. J. Comput. Sci. Issues"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1148\/radiol.2292030516","article-title":"Carotid artery stenosis: Gray-scale and Doppler US diagnosis\u2014Society of radiologists in ultrasound consensus conference","volume":"229","author":"Grant","year":"2003","journal-title":"Radiology"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1109\/TUFFC.2016.2587381","article-title":"Adaptive Spectral Envelope Estimation for Doppler Ultrasound","volume":"63","author":"Kathpalia","year":"2016","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1002\/jcu.20301","article-title":"Doppler sonography evaluation of flow velocity and volume of the extracranial internal carotid and vertebral arteries in healthy adults","volume":"35","author":"Albayrak","year":"2007","journal-title":"J. Clin. Ultrasound"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"281","DOI":"10.5301\/jva.5000118","article-title":"The accuracy of ultrasound volume flow measurements in the complex flow setting of a forearm vascular access","volume":"14","author":"Canneyt","year":"2012","journal-title":"J. Vasc. Access"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1093\/bja\/aem179","article-title":"Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness","volume":"99","author":"Lee","year":"2007","journal-title":"Br. J. Anaesth."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/S0301-5629(02)00565-3","article-title":"Volume blood flow estimation in the normal and growth-restricted fetus","volume":"28","author":"Gardiner","year":"2002","journal-title":"Ultrasound Med. Biol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1088\/0031-9155\/20\/5\/009","article-title":"A spectral approach to ultrasonic scattering from human tissue: Methods, objectives and backscattering measurements","volume":"20","author":"Chivers","year":"1975","journal-title":"Phys. Med. Biol."},{"key":"ref_9","unstructured":"Evans, D.H., McDicken, W.N., Skidmore, R., and Woodcock, J.P. (1989). Doppler Ultrasound: Physics, Instrumentation, and Clinical Applications, Wiley."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/0301-5629(88)90071-3","article-title":"Comparison of four digital maximum frequency estimators for Doppler ultrasound","volume":"14","author":"Mo","year":"1988","journal-title":"Ultrasound Med. Biol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/BF02444029","article-title":"\u2018Objective\u2019 algorithm for maximum frequency estimation in Doppler spectral analysers","volume":"23","year":"1985","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1016\/0301-5629(94)90111-2","article-title":"Comparison of the performance of three maximum Doppler frequency estimators coupled with different spectral estimation methods","volume":"20","author":"Marasek","year":"1994","journal-title":"Ultrasound Med. Biol."},{"key":"ref_13","first-page":"126","article-title":"The performance of three maximum frequency envelope detection algorithms for Doppler signals","volume":"1","author":"Moraes","year":"1995","journal-title":"J. Vascular Invest."},{"key":"ref_14","unstructured":"Steinman, A.H., Tavakkoli, J., Myers, J.G., Cobbold, R.S.C., and Johnston, K.W. (2000, January 23\u201328). A new approach for determining maximum frequency in clinical Doppler ultrasound spectral estimates. Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143), Chicago, IL, USA."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/S0301-5629(01)00352-0","article-title":"Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow","volume":"27","author":"Steinman","year":"2001","journal-title":"Ultrasound Med. Biol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1109\/TBME.2004.826647","article-title":"A mathematical basis for the application of the modified geometric method to maximum frequency estimation","volume":"51","author":"Fernando","year":"2004","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1109\/42.974936","article-title":"Automated analysis of Doppler ultrasound velocity flow diagrams","volume":"20","author":"Tschirren","year":"2001","journal-title":"IEEE Trans. Med. Imag."},{"key":"ref_18","unstructured":"Shechner, O., Sheinovitz, M., Feinberg, M., and Greenspan, H. (2004, January 18). Image analysis of Doppler echocardiography for patients with atrial fibrillation. Proceedings of the 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821), Arlington, VA, USA."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/S0301-5629(02)00575-6","article-title":"Estimation of the Doppler ultrasound maximal umbilical waveform envelope: I. Estimation method","volume":"28","author":"Doherty","year":"2002","journal-title":"Ultrasound Med. Biol."},{"key":"ref_20","unstructured":"Wenlong, F., Johnston, M., and Zhang, M. (2012, January 7\u201311). Genetic programming for edge detection based on figure of merit. Proceedings of the 14th Annual Conference Companion on Genetic and Evolutionary Computation, Philadelphia, PA, USA."},{"key":"ref_21","unstructured":"Wenlong, F., Johnston, M., and Zhang, M. (2016). Genetic Programming for Edge Detection: A Gaussian-Based Approach, Springer."}],"container-title":["Information"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2078-2489\/10\/6\/199\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:56:20Z","timestamp":1760187380000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2078-2489\/10\/6\/199"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,5]]},"references-count":21,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["info10060199"],"URL":"https:\/\/doi.org\/10.3390\/info10060199","relation":{},"ISSN":["2078-2489"],"issn-type":[{"value":"2078-2489","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,5]]}}}