{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,9]],"date-time":"2025-12-09T08:29:42Z","timestamp":1765268982892,"version":"build-2065373602"},"reference-count":36,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T00:00:00Z","timestamp":1725840000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Canon Medical Systems, USA","award":["R01 HL154092","35938"],"award-info":[{"award-number":["R01 HL154092","35938"]}]},{"name":"National Heart, Lung, and Blood Institute of the National Institutes of Health","award":["R01 HL154092","35938"],"award-info":[{"award-number":["R01 HL154092","35938"]}]},{"name":"Canon Medical Systems Corporation, Japan","award":["R01 HL154092","35938"],"award-info":[{"award-number":["R01 HL154092","35938"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Non-contrast magnetic resonance angiography (NC-MRA), including fresh blood imaging (FBI), is a suitable choice for evaluating patients with peripheral artery disease (PAD). We evaluated standard FBI (sFBI) and centric ky-kz FBI (cFBI) acquisitions, using 1D and 2D parallel imaging factors (PIFs) to assess the trade-off between scan time and image quality due to blurring. The bilateral legs of four volunteers (mean age 33 years, two females) were imaged in the coronal plane using a body array coil with a posterior spine coil. Two types of sFBI and cFBI sequences with 1D PIF factor 5 in the phase encode (PE) direction (in-plane) and 2D PIF 3 (PE) \u00d7 2 (slice encode (SE)) (in-plane, through-slice) were studied. Image quality was evaluated by a radiologist, the vessel\u2019s signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured, and major vessel width was measured on the coronal maximum intensity projection (MIP) and 80-degree MIP. Results showed significant time reductions from 184 to 206 s on average when using sFBI down to 98 to 162 s when using cFBI (p = 0.003). Similar SNRs (averaging 200 to 370 across all sequences and PIF) and CNRs (averaging 190 to 360) for all techniques (p &gt; 0.08) were found. There was no significant difference in the image quality (averaging 4.0 to 4.5; p &gt; 0.2) or vessel width (averaging 4.1 to 4.9 mm; p &gt; 0.1) on coronal MIP due to sequence or PIF. However, vessel width measured using 80-degree MIP demonstrated a significantly wider vessel in cFBI (5.6 to 6.8 mm) compared to sFBI (4.5 to 4.7 mm) (p = 0.022), and in 1D (4.7 to 6.8 mm) compared to 2D (4.5 to 5.6 mm) (p &lt; 0.05) PIF. This demonstrated a trade-off in T2 blurring between 1D and 2D PIF: 1D using a PIF of 5 shortened the acquisition window, resulting in sharper arterial blood vessels in coronal images but significant blur in the 80-degree MIP. Two-dimensional PIF for cFBI provided a good balance between shorter scan time (relative to sFBI) and good sharpness in both in- and through-plane, while no benefit of 2D PIF was seen for sFBI. In conclusion, this study demonstrated the usefulness of FBI-based techniques for peripheral artery imaging and underscored the need to strike a balance between scan time and image quality in different planes through the use of 2D parallel imaging.<\/jats:p>","DOI":"10.3390\/jimaging10090223","type":"journal-article","created":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T09:21:00Z","timestamp":1725873660000},"page":"223","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Peripheral Non-Contrast MR Angiography Using FBI: Scan Time and T2 Blurring Reduction with 2D Parallel Imaging"],"prefix":"10.3390","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2616-0339","authenticated-orcid":false,"given":"Won C.","family":"Bae","sequence":"first","affiliation":[{"name":"Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA"},{"name":"Department of Radiology, VA San Diego Healthcare System, San Diego, CA 92161, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lewis","family":"Hahn","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vadim","family":"Malis","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anya","family":"Mesa","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8291-7610","authenticated-orcid":false,"given":"Diana","family":"Vucevic","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5690-694X","authenticated-orcid":false,"given":"Mitsue","family":"Miyazaki","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California-San Diego, La Jolla, CA 92093, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,9,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1161\/01.CIR.0000137913.26087.F0","article-title":"Prevalence of and risk factors for peripheral arterial disease in the United States: Results from the National Health and Nutrition Examination Survey, 1999\u20132000","volume":"110","author":"Selvin","year":"2004","journal-title":"Circulation"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1148\/radiol.11110700","article-title":"Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease","volume":"263","author":"Iezzi","year":"2012","journal-title":"Radiology"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.jvs.2012.10.009","article-title":"Contrast alternatives for iodinated contrast allergy and renal dysfunction: Options and limitations","volume":"57","author":"Nadolski","year":"2013","journal-title":"J. Vasc. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/01.RVI.0000191361.02857.DE","article-title":"CT angiography of peripheral arterial disease","volume":"17","author":"Fleischmann","year":"2006","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"839","DOI":"10.2215\/CJN.04101206","article-title":"Peripheral arterial disease: A guide for nephrologists","volume":"2","author":"DeLoach","year":"2007","journal-title":"Clin. J. Am. Soc. Nephrol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1007\/s003300050237","article-title":"Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculature","volume":"7","author":"Leung","year":"1997","journal-title":"Eur. Radiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1148\/radiology.206.3.9494486","article-title":"Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography","volume":"206","author":"Ho","year":"1998","journal-title":"Radiology"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.rcl.2014.12.003","article-title":"Noncontrast magnetic resonance angiography: Concepts and clinical applications","volume":"53","author":"Lim","year":"2015","journal-title":"Radiol. Clin. N. Am."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1002\/jmri.21969","article-title":"Biodistribution of gadolinium-based contrast agents, including gadolinium deposition","volume":"30","author":"Aime","year":"2009","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1148\/radiol.13131669","article-title":"High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: Relationship with increasing cumulative dose of a gadolinium-based contrast material","volume":"270","author":"Kanda","year":"2014","journal-title":"Radiology"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1148\/radiol.14140364","article-title":"High Signal Intensity in Dentate Nucleus on Unenhanced T1-weighted MR Images: Association with Linear versus Macrocyclic Gadolinium Chelate Administration","volume":"275","author":"Kanda","year":"2015","journal-title":"Radiology"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1148\/radiol.15150025","article-title":"Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging","volume":"275","author":"McDonald","year":"2015","journal-title":"Radiology"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1002\/1522-2586(200011)12:5<776::AID-JMRI17>3.0.CO;2-X","article-title":"Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo","volume":"12","author":"Miyazaki","year":"2000","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1148\/radiol.2273020227","article-title":"Peripheral MR angiography: Separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging","volume":"227","author":"Miyazaki","year":"2003","journal-title":"Radiology"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1002\/mrm.22287","article-title":"Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: Technical considerations and clinical feasibility","volume":"63","author":"Edelman","year":"2010","journal-title":"Magn. Reson. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.1002\/mrm.22142","article-title":"3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP","volume":"62","author":"Fan","year":"2009","journal-title":"Magn. Reson. Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1002\/mrm.22847","article-title":"Determination of the optimal first-order gradient moment for flow-sensitive dephasing magnetization-prepared 3D noncontrast MR angiography","volume":"65","author":"Fan","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1002\/mrm.24561","article-title":"Off-resonance-robust velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography","volume":"70","author":"Shin","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1002\/mrm.25870","article-title":"Identification and reduction of image artifacts in non-contrast-enhanced velocity-selective peripheral angiography at 3T","volume":"76","author":"Shin","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s12968-016-0294-6","article-title":"The diagnostic value of non-contrast enhanced quiescent interval single shot (QISS) magnetic resonance angiography at 3T for lower extremity peripheral arterial disease, in comparison to CT angiography","volume":"18","author":"Wu","year":"2016","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"ref_21","unstructured":"Malis, V., Vucevic, D., Bae, W.C., Yamamoto, A., Kassai, Y., Lane, J., Hsiao, A., Nakamura, K., and Miyazaki, M. Fast Non-Contrast MR Angiography using Zigzag Centric ky-kz k-space Trajectory and exponential refocusing flip angles with restoration of longitudinal magnetization, Magn. Reson. Med. Sci."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Ota, H., Morita, Y., Vucevic, D., Higuchi, S., Takagi, H., Kutsuna, H., Yamashita, Y., Kim, P., and Miyazaki, M. (Magn. Reson. Mater. Phys. Biol. Med., 2024). Motion robust coronary MR angiography using zigzag centric ky-kz trajectory and high-resolution deep learning reconstruction, Magn. Reson. Mater. Phys. Biol. Med., in press.","DOI":"10.1007\/s10334-024-01172-9"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/jmri.22789","article-title":"Non-contrast enhanced MR angiography: Established techniques","volume":"35","author":"Miyazaki","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1148\/radiol.2481071497","article-title":"Nonenhanced MR angiography","volume":"248","author":"Miyazaki","year":"2008","journal-title":"Radiology"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1002\/mrm.1910280103","article-title":"The loss of small objects in variable TE imaging: Implications for FSE, RARE, and EPI","volume":"28","author":"Constable","year":"1992","journal-title":"Magn. Reson. Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1002\/jmri.1880080236","article-title":"A novel MR angiography technique: SPEED acquisition using half-Fourier RARE","volume":"8","author":"Miyazaki","year":"1998","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.mri.2012.04.017","article-title":"Point spread functions of the T2 decay in k-space trajectories with long echo train","volume":"30","author":"Qin","year":"2012","journal-title":"Magn. Reson. Imaging"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1002\/mrm.22970","article-title":"Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation","volume":"67","author":"Lu","year":"2012","journal-title":"Magn. Reson. Med."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.3174\/ajnr.A5771","article-title":"Value of Contrast-Enhanced MRA versus Time-of-Flight MRA in Acute Ischemic Stroke MRI","volume":"39","author":"Boujan","year":"2018","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/RLI.0b013e3181690179","article-title":"Noncontrast 3D steady-state free-precession magnetic resonance angiography of the whole chest using nonselective radiofrequency excitation over a large field of view: Comparison with single-phase 3D contrast-enhanced magnetic resonance angiography","volume":"43","author":"Krishnam","year":"2008","journal-title":"Investig. Radiol."},{"key":"ref_31","unstructured":"Team, J. (JASP, 2024). JASP, Computer software."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","article-title":"Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses","volume":"41","author":"Faul","year":"2009","journal-title":"Behav. Res. Methods"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"17","DOI":"10.3352\/jeehp.2021.18.17","article-title":"Sample size determination and power analysis using the G*Power software","volume":"18","author":"Kang","year":"2021","journal-title":"J. Educ. Eval. Health Prof."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1258\/ar.2012.120008","article-title":"Contrast-enhanced peripheral MRA: Technique and contrast agents","volume":"53","author":"Nielsen","year":"2012","journal-title":"Acta Radiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1002\/jmri.26268","article-title":"Unenhanced Velocity-Selective MR Angiography (VS-MRA): Initial Clinical Evaluation in Patients with Peripheral Artery Disease","volume":"49","author":"Shin","year":"2019","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.ejrad.2009.05.051","article-title":"Non-contrast-enhanced hepatic MR angiography: Do two-dimensional parallel imaging and short tau inversion recovery methods shorten acquisition time without image quality deterioration?","volume":"77","author":"Shimada","year":"2011","journal-title":"Eur. J. Radiol."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/10\/9\/223\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:52:19Z","timestamp":1760111539000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/10\/9\/223"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,9]]},"references-count":36,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2024,9]]}},"alternative-id":["jimaging10090223"],"URL":"https:\/\/doi.org\/10.3390\/jimaging10090223","relation":{},"ISSN":["2313-433X"],"issn-type":[{"type":"electronic","value":"2313-433X"}],"subject":[],"published":{"date-parts":[[2024,9,9]]}}}