{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T13:06:19Z","timestamp":1772802379338,"version":"3.50.1"},"reference-count":13,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2015,8,6]],"date-time":"2015-08-06T00:00:00Z","timestamp":1438819200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>This contribution proposes a new temporal PET camera concept yielding a precise spatio-temporal localization of a scintillation event within a monolithic scintillator. This concept is promising for PET imaging. The key idea behind this concept is the ability of the system to accurately localize the region of detected un-scattered photons on the Si-PMT detector plane. Then, by ray tracing, an accurate estimate of the depth and timing of the scintillation event is provided. An estimation of the potential performance of such a system, based on extensive Monte Carlo simulations, is also presented.<\/jats:p>","DOI":"10.3390\/jimaging1010045","type":"journal-article","created":{"date-parts":[[2015,8,7]],"date-time":"2015-08-07T02:11:56Z","timestamp":1438913516000},"page":"45-59","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["The Temporal PET Camera: A New Concept With High Spatial and Timing Resolution for PET Imaging"],"prefix":"10.3390","volume":"1","author":[{"given":"Alain","family":"Iltis","sequence":"first","affiliation":[{"name":"Damavan Imaging, Technopole de l'Aube, 2 rue Gustave Eiffel, 10000 Troyes, France"}]},{"given":"Hichem","family":"Snoussi","sequence":"additional","affiliation":[{"name":"University of Technology of Troyes Institute Charles Delaunay, UMR CNRS 6279 12, rue Marie Curie, 10010 Troyes, France"}]}],"member":"1968","published-online":{"date-parts":[[2015,8,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2219","DOI":"10.1088\/0031-9155\/57\/8\/2219","article-title":"Monolithic LaBr3: Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography","volume":"57","author":"Seifert","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Anger, H.O. (1963). Gamma-Ray and Positron Scintillation Camera. Nucleonics Ceased Publication, 21, UCRL-10933.","DOI":"10.2172\/164905"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Pani, R., Vittorini, F., Pellegrini, R., Bennati, P., Cinti, M.N., Mattioli, M., and de Notaristefani, F. (2008, January 19\u201325). High spatial and energy resolution gamma imaging based on LaBr3 (Ce) continuous crystals. Proceedings of the Nuclear Science Symposium Conference Record (NSS'08), Dresden, Germany.","DOI":"10.1109\/NSSMIC.2008.4775116"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.nima.2006.02.192","article-title":"Lanthanum halide scintillators: Properties and applications","volume":"563","author":"Iltis","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A: Accel. Spectrom. Detect. Assoc. Equip."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"C01049","DOI":"10.1088\/1748-0221\/9\/01\/C01049","article-title":"Petiroc and Citiroc: Front-end ASICs for SiPM read-out and ToF applications","volume":"9","author":"Fleury","year":"2014","journal-title":"JINST"},{"key":"ref_6","first-page":"161","article-title":"A comparison of count rate parameters in gamma cameras","volume":"22","author":"Lewellen","year":"1981","journal-title":"J. Nucl. Med."},{"key":"ref_7","first-page":"1821","article-title":"Performance of a whole-body PET scanner using curve-plate NaI(Tl) detectors","volume":"42","author":"Adam","year":"2001","journal-title":"J. Nucl. Med."},{"key":"ref_8","unstructured":"Iltis, A. (2012). Syst\u00e8me et Proc\u00e9d\u00e9 de D\u00e9tection de Rayonnement Gamma de Type Gamma camera. (Patent FR 1260596)."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Yamamoto, S. (2013). Development of Si-PM Based Imaging Systems for Molecular Imaging. J. Med. Bioeng., 2.","DOI":"10.12720\/jomb.2.1.16-19"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1097\/00006231-199609000-00006","article-title":"PET imaging using gamma camera systems: A review","volume":"17","author":"Jarritt","year":"1996","journal-title":"Nucl. Med. Commun."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Bourgeois, C. (1998). Interaction particules-mati\u00e8re: Th\u00e9orie, Techniques de l'ing\u00e9nieur. AF3 530.","DOI":"10.51257\/a-v1-af3530"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.nima.2011.11.029","article-title":"Innovative PET detector concept using Si-PMT and continuous crystals","volume":"695","year":"2012","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1007\/BF01366453","article-title":"\u00dcber die Streuung von Strahlung durch freie Elektronen nach der neuen relativistischen Quantendynamik von Dirac","volume":"52","author":"Klein","year":"1929","journal-title":"Z. Phys."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/1\/1\/45\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:50:19Z","timestamp":1760215819000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/1\/1\/45"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,8,6]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,12]]}},"alternative-id":["jimaging1010045"],"URL":"https:\/\/doi.org\/10.3390\/jimaging1010045","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,8,6]]}}}