{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:26:21Z","timestamp":1760243181965,"version":"build-2065373602"},"reference-count":24,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2015,11,20]],"date-time":"2015-11-20T00:00:00Z","timestamp":1447977600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003329","name":"Ministerio de Econom\u00eda y Competitividad","doi-asserted-by":"publisher","award":["IPT-300000-2010-3"],"award-info":[{"award-number":["IPT-300000-2010-3"]}],"id":[{"id":"10.13039\/501100003329","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>In Intraoperative Electron Radiation Therapy (IOERT), the lack of specific planning tools limits its applicability, the need for accurate dosimetry estimation and application during the therapy being the most critical. Recently, some works have been presented that try to overcome some of the limitations for establishing planning tools, though still an accurate guidance system that tracks, in real-time, the applicator and the patient is needed. In these surgical environments, the acquisition of an accurate 3D shape of the patient\u2019s tumor bed in real-time is of high interest, as current systems make use of a 3D model acquired before the treatment. In this paper, an optical-based system is presented that is able to register, in real-time, the different objects (rigid objects) taking part in such a treatment. The presented guidance system and the related methodology are highly interactive, where a usability design has also been provided for non-expert users. Additionally, four different approaches are explored and evaluated to acquire the 3D model of the patient (non-rigid object) in real-time, where accuracies in the range of 1 mm can be achieved without the need of using expensive devices.<\/jats:p>","DOI":"10.3390\/jimaging1010180","type":"journal-article","created":{"date-parts":[[2015,11,24]],"date-time":"2015-11-24T01:57:02Z","timestamp":1448330222000},"page":"180-192","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Towards a Guidance System to Aid in the Dosimetry Calculation of Intraoperative Electron Radiation Therapy"],"prefix":"10.3390","volume":"1","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4520-2250","authenticated-orcid":false,"given":"Cristina","family":"Portal\u00e9s","sequence":"first","affiliation":[{"name":"Universitat de Val\u00e8ncia, Av. de Blasco Ib\u00e1\u00f1ez, 13, Val\u00e8ncia 46010, Spain"}]},{"given":"Jes\u00fas","family":"Gimeno","sequence":"additional","affiliation":[{"name":"Universitat de Val\u00e8ncia, Av. de Blasco Ib\u00e1\u00f1ez, 13, Val\u00e8ncia 46010, Spain"}]},{"given":"Luc\u00eda","family":"Vera","sequence":"additional","affiliation":[{"name":"Universitat de Val\u00e8ncia, Av. de Blasco Ib\u00e1\u00f1ez, 13, Val\u00e8ncia 46010, Spain"}]},{"given":"Marcos","family":"Fern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Universitat de Val\u00e8ncia, Av. de Blasco Ib\u00e1\u00f1ez, 13, Val\u00e8ncia 46010, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2015,11,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Gunderson, L.L., Willett, C.G., Calvo, F.A., and Harrison, L.B. (2011). Intraoperative Irradiation: Techniques and Results, Humana Press. [2nd ed.].","DOI":"10.1007\/978-1-61779-015-7"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e287","DOI":"10.1016\/j.ijrobp.2011.12.063","article-title":"An innovative tool for intraoperative electron beam radiotherapy simulation and planning: Description and initial evaluation by radiation oncologists","volume":"83","author":"Pascau","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00000421-199904000-00008","article-title":"Energy and applicator size and shape used in over 800 intraoperative electron beam therapy fields","volume":"22","author":"Thomas","year":"1999","journal-title":"Am. J. Clin. Oncol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"197","DOI":"10.3171\/jns.1995.83.2.0197","article-title":"Clinical use of a frameless stereotactic arm: Results of 325 cases","volume":"83","author":"Golfinos","year":"1995","journal-title":"J. Neurosurg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/S0196-0709(96)90003-4","article-title":"Computer-assisted intraoperative navigation during skull base surgery","volume":"17","author":"Carrau","year":"1996","journal-title":"Am. J. Otolaryngol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"36","DOI":"10.3171\/jns.1993.79.1.0036","article-title":"Ultrasound-controlled neuronavigator-guided brain surgery","volume":"79","author":"Koivukangas","year":"1993","journal-title":"J. Neurosurg."},{"key":"ref_7","first-page":"608","article-title":"Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration","volume":"41","author":"Hata","year":"1997","journal-title":"Neurosurgery"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/S0929-8266(00)00103-8","article-title":"Ultrasound-guided surgery of deep seated brain lesions","volume":"12","author":"Regelsberger","year":"2000","journal-title":"Eur. J. Ultrasound"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"361","DOI":"10.2500\/105065800779954310","article-title":"Stereotactic computer-assisted navigational sinus surgery: accuracy of an electromagnetic tracking system with the tissue debrider and when utilizing different headsets for the same patient","volume":"14","author":"Javer","year":"2000","journal-title":"Am. J. Rhinol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1097\/01.BRS.0000087851.51547.00","article-title":"Electromagnetic field-based image-guided spine surgery Part one: Results of a cadaveric study evaluating lumbar pedicle screw placement","volume":"28","author":"Sagi","year":"2003","journal-title":"Spine"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"127","DOI":"10.3109\/10929080600751399","article-title":"Electromagnetic tracking for abdominal interventions in computer aided surgery","volume":"11","author":"Zhang","year":"2006","journal-title":"Comput. Aided Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1097\/00005537-199909000-00028","article-title":"A passive-marker-based optical system for computer-aided surgery in otorhinolaryngology: Development and first clinical experiences","volume":"109","author":"Klimek","year":"1999","journal-title":"Laryngoscope"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1097\/00005537-200006000-00017","article-title":"Physician experience with an optical image guidance system for sinus surgery","volume":"110","author":"Metson","year":"2000","journal-title":"Laryngoscope"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.ics.2005.03.194","article-title":"Integration of a surgical robot and intraoperative imaging","volume":"1281","author":"Knoop","year":"2005","journal-title":"Int. Congr. Ser."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Bootsma, G.J., Siewerdsen, J.H., Daly, M.J., and Jaffray, D.A. (2008, January 20\u201325). Initial investigation of an automatic registration algorithm for surgical navigation. Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4649996"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Zahraee, A.H., Szewczyk, J., and Morel, G. (2009, January 14\u201317). Evaluating control modes for hand-held robotic surgical instrument using virtual reality simulator. Proceedings of the 2009 IEEE\/ASME International Conference on Advanced Intelligent Mechatronics, Singapore.","DOI":"10.1109\/AIM.2009.5229774"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"98","DOI":"10.3109\/10929080009148876","article-title":"Comparative tracking error analysis of five different optical tracking systems","volume":"5","author":"Khadem","year":"2000","journal-title":"Comput. Aided Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1002\/rcs.213","article-title":"An integrated system for planning, navigation and robotic assistance for skull base surgery","volume":"4","author":"Xia","year":"2008","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"key":"ref_19","unstructured":"Wikipedia Kinect. Available online:http:\/\/en.wikipedia.org\/wiki\/Kinect."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2666","DOI":"10.1016\/j.patcog.2010.03.004","article-title":"A state of the art in structured light patterns for surface profilometry","volume":"43","author":"Salvi","year":"2010","journal-title":"Pattern Recognit."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.patcog.2003.10.002","article-title":"Pattern codification strategies in structured light systems","volume":"37","author":"Salvi","year":"2004","journal-title":"Pattern Recognit."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1364\/JOSA.72.000156","article-title":"Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry","volume":"72","author":"Takeda","year":"1982","journal-title":"J. Opt. Soc. Am."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"3977","DOI":"10.1364\/AO.22.003977","article-title":"Fourier transform profilometry for the automatic measurement of 3-D object shapes","volume":"22","author":"Takeda","year":"1983","journal-title":"Appl. Opt."},{"key":"ref_24","unstructured":"NUB3D NUB3D Measurement Innovation. Available online:http:\/\/www.nub3d.com\/."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/1\/1\/180\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:52:33Z","timestamp":1760215953000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/1\/1\/180"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,20]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,12]]}},"alternative-id":["jimaging1010180"],"URL":"https:\/\/doi.org\/10.3390\/jimaging1010180","relation":{},"ISSN":["2313-433X"],"issn-type":[{"type":"electronic","value":"2313-433X"}],"subject":[],"published":{"date-parts":[[2015,11,20]]}}}