{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T20:45:42Z","timestamp":1790282742468,"version":"4.1.0"},"reference-count":27,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T00:00:00Z","timestamp":1738713600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Image-based 3D reconstruction enables robot-assisted interventions and image-guided navigation, which are emerging technologies in laparoscopy. When a robotic arm guides a laparoscope for image acquisition, hand\u2013eye calibration is required to know the transformation between the camera and the robot flange. The calibration procedure is complex and must be conducted after each intervention (when the laparoscope is dismounted for cleaning). In the field, the surgeons and their assistants cannot be expected to do so. Thus, our approach is a procedure for a robot-based multi-view 3D reconstruction without hand\u2013eye calibration, but with pose optimization algorithms instead. In this work, a robotic arm and a stereo laparoscope build the experimental setup. The procedure includes the stereo matching algorithm Semi Global Matching from OpenCV for depth measurement and the multiscale color iterative closest point algorithm from Open3D (v0.19), along with the multiway registration algorithm using a pose graph from Open3D (v0.19) for pose optimization. The procedure is evaluated quantitatively and qualitatively on ex vivo organs. The results are a low root mean squared error (1.1\u20133.37 mm) and dense point clouds. The proposed procedure leads to a plausible 3D model, and there is no need for complex hand\u2013eye calibration, as this step can be compensated for by pose optimization algorithms.<\/jats:p>","DOI":"10.3390\/jimaging11020044","type":"journal-article","created":{"date-parts":[[2025,2,6]],"date-time":"2025-02-06T06:30:29Z","timestamp":1738823429000},"page":"44","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Robot-Based Procedure for 3D Reconstruction of Abdominal Organs Using the Iterative Closest Point and Pose Graph Algorithms"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-2564-5751","authenticated-orcid":false,"given":"Birthe","family":"G\u00f6bel","sequence":"first","affiliation":[{"name":"Department of Sustainable Systems Engineering, NATECH, University of Freiburg, Emmy-Noether-Stra\u00dfe 2, 79110 Freiburg, Germany"},{"name":"KARL STORZ SE & Co. KG, Dr.-Karl-Storz-Str. 34, 78532 Tuttlingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Huurdeman","sequence":"additional","affiliation":[{"name":"KARL STORZ SE & Co. KG, Dr.-Karl-Storz-Str. 34, 78532 Tuttlingen, Germany"},{"name":"Institute for Bioinformatics and Medical Informatics (IBMI), University of T\u00fcbingen, Geschwister-Scholl-Platz, 72074 T\u00fcbingen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3196-3876","authenticated-orcid":false,"given":"Alexander","family":"Reiterer","sequence":"additional","affiliation":[{"name":"Department of Sustainable Systems Engineering, NATECH, University of Freiburg, Emmy-Noether-Stra\u00dfe 2, 79110 Freiburg, Germany"},{"name":"Fraunhofer Institute for Physical Measurement Techniques IPM, Georges-K\u00f6hler-Allee 301, 79110 Freiburg im Breisgau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4709-3817","authenticated-orcid":false,"given":"Knut","family":"M\u00f6ller","sequence":"additional","affiliation":[{"name":"Institute of Technical Medicine, ITeM, Furtwangen University (HFU), Jakob-Kienzle-Stra\u00dfe 17, 78054 Villingen-Schwenningen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,2,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Reichard, D., Bodenstedt, S., Suwelack, S., Mayer, B., Preukschas, A., Wagner, M., Kenngott, H., M\u00fcller-Stich, B., Dillmann, R., and Speidel, S. (2015). Intraoperative On-the-Fly Organ- Mosaicking for Laparoscopic Surgery. J. Med. Imaging, 2.","DOI":"10.1117\/1.JMI.2.4.045001"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Su, Y.-H., Lindgren, K., Huang, K., and Hannaford, B. (2020, January 12\u201315). A Comparison of Surgical Cavity 3D Reconstruction Methods. Proceedings of the 2020 IEEE\/SICE International Symposium on System Integration (SII), Honolulu, HI, USA.","DOI":"10.1109\/SII46433.2020.9026289"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1007\/s40846-019-00503-9","article-title":"Designing a New Endoscope for Panoramic-View with Focus-Area 3D-Vision in Minimally Invasive Surgery","volume":"40","author":"Kim","year":"2020","journal-title":"J. Med. Biol. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1049\/htl.2017.0068","article-title":"Real-Time Geometry-Aware Augmented Reality in Minimally Invasive Surgery","volume":"4","author":"Chen","year":"2017","journal-title":"Healthc. Technol. Lett."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.20965\/jaciii.2023.p1216","article-title":"An Automatic and Robust Visual SLAM Method for Intra-Abdominal Environment Reconstruction","volume":"27","author":"Wei","year":"2023","journal-title":"J. Adv. Comput. Intell. Intell. Inform."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Zhang, L., Ye, M., Giataganas, P., Hughes, M., and Yang, G.-Z. (June, January 29). Autonomous Scanning for Endomicroscopic Mosaicing and 3D Fusion. Proceedings of the 2017 IEEE International Conference on Robotics and Automation (ICRA), Singapore.","DOI":"10.1109\/ICRA.2017.7989412"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1049\/htl.2018.5071","article-title":"Fast and Accurate Vision-Based Stereo Reconstruction and Motion Estimation for Image-Guided Liver Surgery","volume":"5","author":"Speers","year":"2018","journal-title":"Healthc. Technol. Lett."},{"key":"ref_8","first-page":"331","article-title":"EMDQ-SLAM: Real-Time High-Resolution Reconstruction of Soft Tissue Surface from Stereo Laparoscopy Videos","volume":"Volume 12904","author":"Zhou","year":"2021","journal-title":"Proceedings of the Medical Image Computing and Computer Assisted Intervention\u2013MICCAI 2021: 24th International Conference"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Handa, A., Gaidhane, A., and Choudhari, S.G. (2024). Role of Robotic-Assisted Surgery in Public Health: Its Advantages and Challenges. Cureus, 16.","DOI":"10.7759\/cureus.62958"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Bramhe, S., and Pathak, S.S. (2022). Robotic Surgery: A Narrative Review. Cureus, 14.","DOI":"10.7759\/cureus.29179"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s13193-020-01093-8","article-title":"Robotic Surgery-Safety and Effectiveness, in Comparison with Traditional Surgery, Present Context and Recent FDA Safety Warning","volume":"11","author":"Boyina","year":"2020","journal-title":"Indian J. Surg. Oncol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1007\/s41315-024-00390-7","article-title":"Binocular-Based Dense 3D Reconstruction for Robotic Assisted Minimally Invasive Laparoscopic Surgery","volume":"8","author":"Sui","year":"2024","journal-title":"Int. J. Intell. Robot. Appl."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1146\/annurev-control-062420-090543","article-title":"Autonomy in Surgical Robotics","volume":"4","author":"Attanasio","year":"2021","journal-title":"Annu. Rev. Control Robot. Auton. Syst."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Saeidi, H., Opfermann, J.D., Kam, M., Wei, S., Leonard, S., Hsieh, M.H., Kang, J.U., and Krieger, A. (2022). Autonomous Robotic Laparoscopic Surgery for Intestinal Anastomosis. Sci. Robot., 7.","DOI":"10.1126\/scirobotics.abj2908"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Han, J., Davids, J., Ashrafian, H., Darzi, A., Elson, D.S., and Sodergren, M. (2022). A Systematic Review of Robotic Surgery: From Supervised Paradigms to Fully Autonomous Robotic Approaches. Int. J. Med. Robot. Comput. Assist. Surg., 18.","DOI":"10.1002\/rcs.2358"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1109\/70.34770","article-title":"A New Technique for Fully Autonomous and Efficient 3D Robotics Hand\/Eye Calibration","volume":"5","author":"Tsai","year":"1989","journal-title":"IEEE Trans. Robot. Autom."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"113143","DOI":"10.1109\/ACCESS.2021.3104514","article-title":"A Comparative Review of Hand-Eye Calibration Techniques for Vision Guided Robots","volume":"9","author":"Enebuse","year":"2021","journal-title":"IEEE Access"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1109\/LRA.2020.2967685","article-title":"Hand-Eye Calibration of Surgical Instrument for Robotic Surgery Using Interactive Manipulation","volume":"5","author":"Zhong","year":"2020","journal-title":"IEEE Robot. Autom. Lett."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2071","DOI":"10.1109\/LRA.2018.2809495","article-title":"Leveraging the Fulcrum Point in Robotic Minimally Invasive Surgery","volume":"3","author":"Gruijthuijsen","year":"2018","journal-title":"IEEE Robot. Autom. Lett."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/j.media.2013.04.003","article-title":"Optical Techniques for 3D Surface Reconstruction in Computer-Assisted Laparoscopic Surgery","volume":"17","author":"Mountney","year":"2013","journal-title":"Med. Image Anal."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"G\u00f6bel, B., Reiterer, A., and M\u00f6ller, K. (2024). Image-Based 3D Reconstruction in Laparoscopy: A Review Focusing on the Quantitative Evaluation by Applying the Reconstruction Error. J. Imaging, 10.","DOI":"10.3390\/jimaging10080180"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Park, J., Zhou, Q.-Y., and Koltun, V. (2017, January 22\u201329). Colored Point Cloud Registration Revisited. Proceedings of the 2017 IEEE International Conference on Computer Vision (ICCV), Venice, Italy.","DOI":"10.1109\/ICCV.2017.25"},{"key":"ref_23","unstructured":"Choi, S., Zhou, Q.-Y., and Koltun, V. (2015, January 7\u201312). Robust Reconstruction of Indoor Scenes. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Boston, MA, USA."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1109\/MITS.2010.939925","article-title":"A Tutorial on Graph-Based SLAM","volume":"2","author":"Grisetti","year":"2010","journal-title":"IEEE Intell. Transp. Syst. Mag."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1145\/2487228.2487237","article-title":"Screened Poisson Surface Reconstruction","volume":"32","author":"Kazhdan","year":"2013","journal-title":"ACM Trans. Graph."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1055\/s-2007-1001366","article-title":"An Ergonomic Analysis of the Fulcrum Effect in the Acquisition of Endoscopic Skills","volume":"30","author":"Gallagher","year":"1998","journal-title":"Endoscopy"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Wang, L., Wu, B., Wang, X., Zhu, Q., and Xu, K. (2022). Endoscopic Image Luminance Enhancement Based on the Inverse Square Law for Illuminance and Retinex. Int. J. Med. Robot. Comput. Assist. Surg., 18.","DOI":"10.1002\/rcs.2396"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/11\/2\/44\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:27:32Z","timestamp":1760027252000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/11\/2\/44"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,5]]},"references-count":27,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["jimaging11020044"],"URL":"https:\/\/doi.org\/10.3390\/jimaging11020044","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,5]]}}}