{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T00:13:57Z","timestamp":1769040837622,"version":"3.49.0"},"reference-count":26,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T00:00:00Z","timestamp":1768953600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Chest radiography remains one of the most frequently performed imaging examinations, highlighting the need for optimization of acquisition parameters to balance image quality and radiation dose. This study presents a phantom-based quantitative evaluation of chest radiography acquisition settings using a digital radiography system (AGFA DR 600). Measurements were performed at three tube voltage levels across simulated patient-equivalent thicknesses generated using PMMA slabs, with a Leeds TOR 15FG image quality phantom positioned centrally in the imaging setup. Image quality was quantitatively assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), which were calculated from mean pixel values obtained from repeated acquisitions. Radiation exposure was evaluated through estimation of entrance surface dose (ESD). The analysis demonstrated that dose-normalized performance metrics favored intermediate tube voltages for slim and average patient-equivalent thicknesses, while higher voltages were required to maintain image quality in obese-equivalent conditions. Overall, image quality and dose were found to be strongly dependent on the combined selection of tube voltage and phantom thickness. These findings indicate that modest adjustments to tube voltage selection may improve the balance between image quality and radiation dose in chest radiography. Nevertheless, as the present work is based on phantom measurements, further validation using clinical images and observer-based studies is required before any modification of routine radiographic practice.<\/jats:p>","DOI":"10.3390\/jimaging12010049","type":"journal-article","created":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T08:48:08Z","timestamp":1768985288000},"page":"49","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Chest Radiography Optimization: Identifying the Optimal kV for Image Quality in a Phantom Study"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3165-9022","authenticated-orcid":false,"given":"Ioannis","family":"Antonakos","sequence":"first","affiliation":[{"name":"Department of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-6478-9738","authenticated-orcid":false,"given":"Kyriakos","family":"Kokkinogoulis","sequence":"additional","affiliation":[{"name":"Department of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Giannopoulou","sequence":"additional","affiliation":[{"name":"Department of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2747-3353","authenticated-orcid":false,"given":"Efstathios P.","family":"Efstathopoulos","sequence":"additional","affiliation":[{"name":"Department of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,1,21]]},"reference":[{"key":"ref_1","unstructured":"IAEA (2001). Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy. Proceedings of an International Conference, IAEA."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Joarder, R., and Crundwell, N. (2009). Chest X-Ray in Clinical Practice, Springer.","DOI":"10.1007\/978-1-84882-099-9"},{"key":"ref_3","unstructured":"United Nations Scientific Committee on the Effects of Atomic Radiation (2000). Sources and Effects of Ionizing Radiation, UN Publications."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Kamposioras, K., Casazza, G., Mauri, D., Lakiotis, V., Cortinovis, I., Xilomenos, A., Peponi, C., Golfinopoulos, V., Milousis, A., and Kakaridis, D. (2006). Screening chest radiography: Results from a Greek cross-sectional survey. BMC Public Health, 6.","DOI":"10.1186\/1471-2458-6-113"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"76","DOI":"10.3109\/13814780509178242","article-title":"Screening chest radiography in primary care: An underestimated belief","volume":"11","author":"Proiskos","year":"2005","journal-title":"Eur. J. Gen. Pract."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s13246-012-0125-5","article-title":"Digital chest radiography image quality assessment with dose reduction","volume":"35","author":"Grewal","year":"2012","journal-title":"Australas. Phys. Eng. Sci. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1093\/rpd\/nct073","article-title":"Radiation dose measurements for optimisation of chest X-ray examinations of children in general radiography hospitals","volume":"156","author":"Suliman","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1007\/s00117-017-0242-y","article-title":"Frequency and doses of diagnostic and interventional X-ray applications: Trends between 2007 and 2014","volume":"57","author":"Nekolla","year":"2017","journal-title":"Radiologe"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1093\/rpd\/nch538","article-title":"Patient exposure in medical X-ray imaging in Europe","volume":"114","author":"Regulla","year":"2005","journal-title":"Radiat. Prot. Dosim."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/HP.0b013e31823513ff","article-title":"Exposure of the Swiss population by medical x-rays: 2008 review","volume":"102","author":"Samara","year":"2012","journal-title":"Health Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/S0140-6736(04)15433-0","article-title":"Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries","volume":"363","author":"Darby","year":"2004","journal-title":"Lancet"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1007\/s00330-015-3836-7","article-title":"European Guidelines for AP\/PA chest X-rays: Routinely satisfiable in a paediatric radiology division?","volume":"26","author":"Tschauner","year":"2015","journal-title":"Eur. Radiol."},{"key":"ref_13","unstructured":"Medical Radiation Practice Board of Australia (2014). Code of Conduct for Medical Radiation Practitioners."},{"key":"ref_14","first-page":"100754","article-title":"Evaluation of the Entrance Surface Doses (ESD) for common diagnostic X-ray examinations","volume":"16","author":"Alomairy","year":"2023","journal-title":"J. Radiat. Res. Appl. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/j.radi.2020.08.012","article-title":"Optimisation of radiographic acquisition parameters for direct digital radiography: A systematic review","volume":"27","author":"Steffensen","year":"2021","journal-title":"Radiography"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"e70191","DOI":"10.1002\/acm2.70191","article-title":"Patient-size based dose optimization in projection radiography examinations: A BMI-guided approach","volume":"26","author":"Welarathna","year":"2025","journal-title":"J. Appl. Clin. Med Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1148\/radiol.2352031730","article-title":"Flat-panel-detector chest radiography: Effect of tube voltage on image quality","volume":"235","author":"Uffmann","year":"2005","journal-title":"Radiology"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1093\/rpd\/nch542","article-title":"The influence of patient thickness and imaging system on patient dose and physical image quality in digital chest imaging","volume":"114","author":"Ullman","year":"2005","journal-title":"Radiat. Prot. Dosim."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1259\/bjr\/21963665","article-title":"Investigation of optimum X-ray beam tube voltage and filtration for chest radiography with a computed radiography system","volume":"81","author":"Moore","year":"2008","journal-title":"Br. J. Radiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1259\/bjr\/33291071","article-title":"A phantom approach to find the optimal technical parameters for plain chest radiography","volume":"77","author":"Vassileva","year":"2004","journal-title":"Br. J. Radiol."},{"key":"ref_21","first-page":"3482458","article-title":"Optimization of Image Quality and Organ Absorbed Dose for Pediatric Chest X-Ray Examination: In-House Developed Chest Phantom Study","volume":"2022","author":"Pengpan","year":"2022","journal-title":"Radiol. Res. Pr."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1259\/bjr.75.898.750837","article-title":"A phantom for dose-image quality optimization in chest radiography","volume":"75","author":"Vassileva","year":"2002","journal-title":"Br. J. Radiol."},{"key":"ref_23","unstructured":"(2025, October 02). DR 600 Ceiling. Available online: https:\/\/agfaradiologysolutions.com\/products\/dr-600\/."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.ejmp.2012.02.001","article-title":"Comparative performance evaluation of a flat detector and an image intensifier angiographic system both used for interventional cardiology procedures in adult and pediatric patients","volume":"29","author":"Kordolaimi","year":"2013","journal-title":"Phys. Medica"},{"key":"ref_25","unstructured":"Brahme, A. (2014). 2.02\u2014Physical Parameters of Image Quality. Comprehensive Biomedical Physics, Elsevier."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"20180022","DOI":"10.1259\/bjr.20180022","article-title":"Radiation dose optimisation for conventional imaging in infants and newborns using automatic dose management software: An application of the new 2013\/59 EURATOM directive","volume":"91","author":"Alejo","year":"2018","journal-title":"Br. J. Radiol."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/12\/1\/49\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T09:17:52Z","timestamp":1768987072000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/12\/1\/49"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,21]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1]]}},"alternative-id":["jimaging12010049"],"URL":"https:\/\/doi.org\/10.3390\/jimaging12010049","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,21]]}}}