{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T13:15:29Z","timestamp":1785417329188,"version":"3.56.0"},"reference-count":43,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["#R01-EB012289"],"award-info":[{"award-number":["#R01-EB012289"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100000866","name":"Cardiff University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100000866","id-type":"DOI","asserted-by":"crossref"}]},{"id":[{"id":"https:\/\/ror.org\/03kk7td41","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Excitation using nonlinear gradient magnetic fields is investigated as a means of sub-volume magnetic resonance imaging (MRI). Conventional gradient fields provide encoding along a single direction, whereas nonlinear gradient fields encode information simultaneously along at least two directions. This leads to excitation regions (FOX) that have curvilinear boundaries, which may be more tolerant to aliasing artifacts when the encoded field of view (FOV) is smaller than the FOX. This reduces the complexity of the required radiofrequency (RF) excitation pulses and enables accelerated reduced-FOV imaging with standard slice-selection RF-pulses. We demonstrate the approach using a Z2-harmonic field for cylindrical regions of interest (ROIs) with various radius\/height ratios. The minimum-FOV that should be encoded is formulated in terms of ROI and RF pulse parameters to allow a theoretical evaluation of feasibility during study design. The investigated method is compared to one-dimensional and two-dimensional selective RF pulses in terms of echo time, scan time and specific absorption rate (SAR) using simulations and phantom experiments. The investigated method yields lower scan time while keeping the SAR unaltered compared to a conventional slice-selective RF pulse, and is more efficient in terms of SAR, echo time and scan time compared to two-dimensional selective excitation.<\/jats:p>","DOI":"10.3390\/jimaging12060261","type":"journal-article","created":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T05:59:47Z","timestamp":1781503187000},"page":"261","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["SAR-Efficient Sub-Volume Imaging Using Nonlinear Gradient Magnetic Fields"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8982-4441","authenticated-orcid":false,"given":"Emre","family":"Kopanoglu","sequence":"first","affiliation":[{"name":"Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff CF24 4HQ, UK"},{"name":"Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA"},{"name":"National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara 06800, T\u00fcrkiye"},{"name":"Department of Electrical and Electronics Engineering, Bilkent University, Ankara 06800, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ergin","family":"Atalar","sequence":"additional","affiliation":[{"name":"National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara 06800, T\u00fcrkiye"},{"name":"Department of Electrical and Electronics Engineering, Bilkent University, Ankara 06800, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Todd","family":"Constable","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA"},{"name":"Department of Neurosurgery, Yale University, New Haven, CT 06520, USA"},{"name":"Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"L457","DOI":"10.1088\/0022-3719\/7\/24\/006","article-title":"Image-Formation in Nmr by a Selective Irradiative Process","volume":"7","author":"Garroway","year":"1974","journal-title":"J. Phys. C-Solid State Phys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1063\/1.1137180","article-title":"NMR imaging techniques and applications: A review","volume":"53","author":"Bottomley","year":"1982","journal-title":"Rev. Sci. Instrum."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1002\/jmri.1880080426","article-title":"MR-guided biopsy using a T2-weighted single-shot zoom imaging sequence (Local Look technique)","volume":"8","author":"Buecker","year":"1998","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_4","first-page":"567","article-title":"Projection Presaturation-A Fast and Accurate Technique for Multidimensional Spatial Localization","volume":"87","author":"Singh","year":"1990","journal-title":"J. Magn. Reson."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4284","DOI":"10.1063\/1.339103","article-title":"Two-Dimensional Spatially Selective Spin Inversion and Spin-Echo Refocusing with a Single Nuclear-Magnetic-Resonance Pulse","volume":"62","author":"Bottomley","year":"1987","journal-title":"J. Appl. Phys."},{"key":"ref_6","first-page":"258","article-title":"Flash Imaging-Rapid Nmr Imaging Using Low Flip-Angle Pulses","volume":"67","author":"Haase","year":"1986","journal-title":"J. Magn. Reson."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1002\/mrm.20011","article-title":"Parallel excitation with an array of transmit coils","volume":"51","author":"Zhu","year":"2004","journal-title":"Magn. Reson. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1002\/mrm.10353","article-title":"Transmit SENSE","volume":"49","author":"Katscher","year":"2003","journal-title":"Magn. Reson. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1002\/mrm.22830","article-title":"Analytic expressions for the ultimate intrinsic signal-to-noise ratio and ultimate intrinsic specific absorption rate in MRI","volume":"66","author":"Kopanoglu","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1002\/mrm.1910380414","article-title":"Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays","volume":"38","author":"Sodickson","year":"1997","journal-title":"Magn. Reson. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: Sensitivity encoding for fast MRI","volume":"42","author":"Pruessmann","year":"1999","journal-title":"Magn. Reson. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"Griswold","year":"2002","journal-title":"Magn. Reson. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1002\/mrm.22066","article-title":"General formulation for quantitative G-factor calculation in GRAPPA reconstructions","volume":"62","author":"Breuer","year":"2009","journal-title":"Magn. Reson. Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1007\/BF01114832","article-title":"Topical magnetic resonance","volume":"2","author":"Gordon","year":"1982","journal-title":"Biosci. Rep."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1038\/287736a0","article-title":"Localization of metabolites in animals using 31P topical magnetic resonance","volume":"287","author":"Gordon","year":"1980","journal-title":"Nature"},{"key":"ref_16","first-page":"522","article-title":"Enhanced Surface-Coil Spatial Localization with an Inhomogeneous Surface Gradient","volume":"65","author":"Crowley","year":"1985","journal-title":"J. Magn. Reson."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1002\/jmri.1880080429","article-title":"Reduction of field of view in MRI using a surface-spoiling local gradient insert","volume":"8","author":"Wiesler","year":"1998","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1620","DOI":"10.1002\/mrm.23146","article-title":"Localization by nonlinear phase preparation and k-space trajectory design","volume":"67","author":"Witschey","year":"2012","journal-title":"Magn. Reson. Med."},{"key":"ref_19","first-page":"364","article-title":"Spatial Localization of Nmr Signal with a Passive Surface Gradient","volume":"80","author":"Malloy","year":"1988","journal-title":"J. Magn. Reson."},{"key":"ref_20","first-page":"179","article-title":"Homogeneity spoil spectroscopy as a tool of spectrum localization for in vivo spectroscopy","volume":"75","author":"Hennig","year":"1987","journal-title":"J. Magn. Reson."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1002\/mrm.1910180108","article-title":"New spatial localization method using pulsed high-order field gradients (SHOT: Selection with High-Order gradienT)","volume":"18","author":"Oh","year":"1991","journal-title":"Magn. Reson. Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s10334-008-0105-7","article-title":"Parallel imaging in non-bijective, curvilinear magnetic field gradients: A concept study","volume":"21","author":"Hennig","year":"2008","journal-title":"Magn. Reson. Mater. Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1002\/mrm.22425","article-title":"O-space imaging: Highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding","volume":"64","author":"Stockmann","year":"2010","journal-title":"Magn. Reson. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"5804","DOI":"10.1002\/mp.15100","article-title":"Feasibility of diffusion weighting with a local inside-out nonlinear gradient coil for prostate MRI","volume":"48","author":"Dewdney","year":"2021","journal-title":"Med. Phys."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1002\/mrm.25703","article-title":"Fast rotary nonlinear spatial acquisition (FRONSAC) imaging","volume":"75","author":"Wang","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_26","first-page":"2734","article-title":"Fast and silent MRI using nonlinear gradient fields at the ultrasonic gradient switching frequency of 20 kHz with a Point Spread Function framework reconstruction","volume":"92","author":"McGrory","year":"2024","journal-title":"Magn. Reson. Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1002\/mrm.24478","article-title":"Specific absorption rate reduction using nonlinear gradient fields","volume":"70","author":"Kopanoglu","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1002\/mrm.25423","article-title":"Radiofrequency pulse design using nonlinear gradient magnetic fields","volume":"74","author":"Kopanoglu","year":"2015","journal-title":"Magn. Reson. Med."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1002\/mrm.24559","article-title":"PexLoc-Parallel excitation using local encoding magnetic fields with nonlinear and nonbijective spatial profiles","volume":"70","author":"Haas","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3187","DOI":"10.1002\/mrm.70277","article-title":"Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration","volume":"95","author":"Holl","year":"2026","journal-title":"Magn. Reson. Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1002\/mrm.1910120107","article-title":"Localized volume selection technique using an additional radial gradient coil","volume":"12","author":"Lee","year":"1989","journal-title":"Magn. Reson. Med."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1002\/mrm.1910320214","article-title":"A new 3D localization technique using quadratic field gradients","volume":"32","author":"Wu","year":"1994","journal-title":"Magn. Reson. Med."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1002\/mrm.1910170214","article-title":"Application of single-shot spiral scanning for volume localization","volume":"17","author":"Ra","year":"1991","journal-title":"Magn. Reson. Med."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1002\/mrm.24259","article-title":"Reduced field-of-view excitation using second-order gradients and spatial-spectral radiofrequency pulses","volume":"69","author":"Ma","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_35","unstructured":"Kopanoglu, E., Yilmaz, U., Akin, B., Acikel, V., and Atalar, E. (2012, January 5\u201311). localizing the excitation to reduce scan time using nonlinear gradient fields. Proceedings of the 20th Scientific Meeting of the International Society for Magnetic Resonance in Medicine (ISMRM), Melbourne, Australia."},{"key":"ref_36","unstructured":"Kopanoglu, E., Atalar, E., and Constable, R.T. (2013, January 10\u201316). Reduced-FOV Imaging with Excitation Using Nonlinear Gradient Magnetic Fields (ENiGMa). Proceedings of the 21st Annual Meeting of the International Society for Magnetic Resonance in Medicine (ISMRM), Salt Lake City, UT, USA."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1109\/42.75611","article-title":"Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]","volume":"10","author":"Pauly","year":"1991","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_38","first-page":"43","article-title":"A K-Space Analysis of Small-Tip-Angle Excitation","volume":"81","author":"Pauly","year":"1989","journal-title":"J. Magn. Reson."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"409","DOI":"10.6028\/jres.049.044","article-title":"Methods of conjugate gradients for solving linear systems","volume":"49","author":"Hestenes","year":"1952","journal-title":"J. Res. Natl. Bur. Stand."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1002\/mrm.21042","article-title":"Parallel RF transmission with eight channels at 3 Tesla","volume":"56","author":"Setsompop","year":"2006","journal-title":"Magn. Reson. Med."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1002\/mrm.24364","article-title":"Excitation and geometrically matched local encoding of curved slices","volume":"69","author":"Weber","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1002\/mrm.22672","article-title":"Simultaneously driven linear and nonlinear spatial encoding fields in MRI","volume":"65","author":"Gallichan","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1002\/mrm.24282","article-title":"In vivo O-Space imaging with a dedicated 12 cm Z2 insert coil on a human 3T scanner using phase map calibration","volume":"69","author":"Stockmann","year":"2013","journal-title":"Magn. Reson. Med."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/12\/6\/261\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T04:34:22Z","timestamp":1781843662000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/12\/6\/261"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,13]]},"references-count":43,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["jimaging12060261"],"URL":"https:\/\/doi.org\/10.3390\/jimaging12060261","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,13]]}}}