{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T04:27:25Z","timestamp":1772252845560,"version":"3.50.1"},"reference-count":23,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T00:00:00Z","timestamp":1513814400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Speckle noise reduction is an important area of research in the field of ultrasound image processing. Several algorithms for speckle noise characterization and analysis have been recently proposed in the area. Synthetic ultrasound images can play a key role in noise evaluation methods as they can be used to generate a variety of speckle noise models under different interpolation and sampling schemes, and can also provide valuable ground truth data for estimating the accuracy of the chosen methods. However, not much work has been done in the area of modeling synthetic ultrasound images, and in simulating speckle noise generation to get images that are as close as possible to real ultrasound images. An important aspect of simulated synthetic ultrasound images is the requirement for extensive quality assessment for ensuring that they have the texture characteristics and gray-tone features of real images. This paper presents texture feature analysis of synthetic ultrasound images using local binary patterns (LBP) and demonstrates the usefulness of a set of LBP features for image quality assessment. Experimental results presented in the paper clearly show how these features could provide an accurate quality metric that correlates very well with subjective evaluations performed by clinical experts.<\/jats:p>","DOI":"10.3390\/jimaging4010003","type":"journal-article","created":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T12:16:14Z","timestamp":1513858574000},"page":"3","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Texture Based Quality Analysis of Simulated Synthetic Ultrasound Images Using Local Binary Patterns"],"prefix":"10.3390","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2770-9493","authenticated-orcid":false,"given":"Prerna","family":"Singh","sequence":"first","affiliation":[{"name":"Department of Computer Science and Software Engineering, University of Canterbury, Christchurch 8041, New Zealand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4578-1931","authenticated-orcid":false,"given":"Ramakrishnan","family":"Mukundan","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Software Engineering, University of Canterbury, Christchurch 8041, New Zealand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rex","family":"De Ryke","sequence":"additional","affiliation":[{"name":"Radiology Services, Canterbury District Health Board, Christchurch 8140, New Zealand"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,12,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Zhang, J., Cui, W., Wu, L., Lin, G., and Cheng, Y. (2016, January 28\u201330). A novel algorithm based on wavelet-trilateral filter for de-noising medical ultrasound images. Proceedings of the Control and Decision Conference 2016, Yinchuan, China.","DOI":"10.1109\/CCDC.2016.7531648"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Malutan, R., Terebes, R., Germain, C., Borda, M., and Cislariu, M. (2015, January 19\u201321). Speckle noise removal in ultrasound images using sparse code shrinkage. Proceedings of the IEEE International Conference on E-Health and Bioengineering 2015, Iasi, Romania.","DOI":"10.1109\/EHB.2015.7391394"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Le, T. (2014, January 13). Adaptive noise reduction in ultrasound imaging. Proceedings of the IEEE Symposium on Signal Processing in Medicine and Biology, Philadelphia, PA, USA.","DOI":"10.1109\/SPMB.2014.7002961"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1109\/TBME.2015.2494838","article-title":"Methods for 2D and 3D endobronchial ultrasound image segmentation","volume":"63","author":"Zang","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_5","first-page":"447","article-title":"Ultrasound image dataset for image analysis algorithms evaluation","volume":"Volume 45","author":"Chen","year":"2016","journal-title":"Innovation in Medicine and Healthcare. Smart Innovation, Systems and Technologies"},{"key":"ref_6","unstructured":"(2017, January 30). Telmed Ultrasound Medical Systems. Available online: http:\/\/www.pcultrasound.com\/products\/products_usimg\/index.html."},{"key":"ref_7","unstructured":"Antony, J. (2017, March 15). Ultrasound Image Gallery. Available online: http:\/\/www.ultrasound-images.com\/."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Loizou, C.P., and Pattichis, C.S. (2015). Despeckle Filtering for Ultrasound Imaging and Video, Morgan & Claypool. Algorithms and Software.","DOI":"10.1007\/978-3-031-01523-6"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Perreault, C., and Auclair-Fortier, M.F. (2007, January 28\u201330). Speckle simulation based on B-mode echographic image acquisition model. Proceedings of the 4th Canadian Conference on Computer and Robot Vision (CRV 2007), Montreal, QC, Canada.","DOI":"10.1109\/CRV.2007.61"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Singh, P., Mukundan, R., and de Ryke, R. (2017, January 4\u20136). Quality analysis of synthetic ultrasound images using co-occurrence texture statistics. Proceedings of the Image and Vision Computing (IVCNZ2017), Christchurch, New Zealand.","DOI":"10.1109\/IVCNZ.2017.8402511"},{"key":"ref_11","unstructured":"Pietikainen, M., Zhao, G., Hadid, A., and Ahonen, T. Computer Vision Using Local Binary Patterns, Springer."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Zhang, M., Xie, J., Zhou, X., and Fujita, H. (2013, January 17\u201320). No reference image quality assessment based on local binary pattern statistics. Proceedings of the Visual Communications and Image Processing (VCIP) 2013, Kuching, Malaysia.","DOI":"10.1109\/VCIP.2013.6706418"},{"key":"ref_13","unstructured":"Hern\u00e1ndez, M., and Gonzalez-Castro, V. (2017). Modelling, Speckle Simulation and Quality Evaluation of Synthetic Ultrasound Images. Communications in Computer and Information Science, Springer International Publishing."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Singh, P., Mukundan, R., and de Ryke, R. (2017, January 16\u201318). Synthetic Models of Ultrasound Image Formation for Speckle Noise Simulation and Analysis. Proceedings of the IEEE International Conference on Signals and Systems 2017, Bali, Indonesia.","DOI":"10.1109\/ICSIGSYS.2017.7967056"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Somawirata, I.K., Uchimura, K., and Koutaki, G. (2012, January 12\u201315). Image enlargement using adaptive manipulation interpolation kernel based on local image data. Proceedings of the IEEE International Conference on Signal Processing, Communication and Computing 2012, Hong Kong, China.","DOI":"10.1109\/ICSPCC.2012.6335692"},{"key":"ref_16","unstructured":"Li, K.-Y., Wang, W.-D., Zheng, K.-W., Liu, W.-B., and Xu, G.-L. (2014, January 15\u201317). The application of B-spline based interpolation in real-time image enlarging processing. Proceedings of the 2nd International Conference on Systems and Informatics 2014, Shanghai, China."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Goceri, E., and Lomenie, N. (2010, January 20\u201322). Interpolation approaches and spline based resampling for MR images. Proceedings of the 5th International Symposium on Health Informatics and Bioinformatics, Antalya, Turkey.","DOI":"10.1109\/HIBIT.2010.5478891"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Xia, Z.W., Li, Q., and Wang, Q. (2012, January 23\u201325). Quality metrics of simulated intensity images of coherent ladar. Proceedings of the International Conference on Optoelectronics and Microelectronics, Jilin, China.","DOI":"10.1109\/ICoOM.2012.6316255"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Mirza, S., Kumar, R., and Shakher, C. (2005). Study of various preprocessing schemes and wavelet filters for speckle noise reduction in digital speckle pattern interferometric fringes. Opt. Eng., 44.","DOI":"10.1117\/1.1886749"},{"key":"ref_20","first-page":"3","article-title":"Reliability of objective picture quality measures","volume":"55","author":"Grgic","year":"2004","journal-title":"J. Electr. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Burger, W., and Burge, M.J. (2008). Digital Image Processing: An Algorithmic Introduction Using Java, Springer.","DOI":"10.1007\/978-1-84628-968-2"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s11263-006-9794-4","article-title":"Local features and kernels for classification of texture and object categories: A comparative study","volume":"73","author":"Zhang","year":"2007","journal-title":"Int. J. Comput. Vis."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1109\/TMI.2009.2038575","article-title":"Quantitative Analysis of Pulmonary Emphysema using Local Binary Patterns","volume":"29","author":"Shaker","year":"2010","journal-title":"IEEE Trans. Med. Imaging"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/4\/1\/3\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:54:54Z","timestamp":1760208894000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/4\/1\/3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,21]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,1]]}},"alternative-id":["jimaging4010003"],"URL":"https:\/\/doi.org\/10.3390\/jimaging4010003","relation":{"has-preprint":[{"id-type":"doi","id":"10.20944\/preprints201710.0181.v1","asserted-by":"object"}]},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,12,21]]}}}