{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T12:33:27Z","timestamp":1770554007239,"version":"3.49.0"},"reference-count":21,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2018,6,7]],"date-time":"2018-06-07T00:00:00Z","timestamp":1528329600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>The diffraction contrast modalities accessible by X-ray grating interferometers are not imaged directly but have to be inferred from sine-like signal variations occurring in a series of images acquired at varying relative positions of the interferometer\u2019s gratings. The absolute spatial translations involved in the acquisition of these phase stepping series usually lie in the range of only a few hundred nanometers, wherefore positioning errors as small as 10 nm will already translate into signal uncertainties of 1\u201310% in the final images if not accounted for. Classically, the relative grating positions in the phase stepping series are considered input parameters to the analysis and are, for the Fast Fourier Transform that is typically employed, required to be equidistantly distributed over multiples of the gratings\u2019 period. In the following, a fast converging optimization scheme is presented simultaneously determining the phase stepping curves\u2019 parameters as well as the actually performed motions of the stepped grating, including also erroneous rotational motions which are commonly neglected. While the correction of solely the translational errors along the stepping direction is found to be sufficient with regard to the reduction of image artifacts, the possibility to also detect minute rotations about all axes proves to be a valuable tool for system calibration and monitoring. The simplicity of the provided algorithm, in particular when only considering translational errors, makes it well suitable as a standard evaluation procedure also for large image series.<\/jats:p>","DOI":"10.3390\/jimaging4060077","type":"journal-article","created":{"date-parts":[[2018,6,8]],"date-time":"2018-06-08T03:13:18Z","timestamp":1528427598000},"page":"77","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Optimization Based Evaluation of Grating Interferometric Phase Stepping Series and Analysis of Mechanical Setup Instabilities"],"prefix":"10.3390","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4403-3686","authenticated-orcid":false,"given":"Jonas","family":"Dittmann","sequence":"first","affiliation":[{"name":"Lehrstuhl f\u00fcr R\u00f6ntgenmikroskopie, Universit\u00e4t W\u00fcrzburg, Josef-Martin-Weg 63, 97074 W\u00fcrzburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Balles","sequence":"additional","affiliation":[{"name":"Lehrstuhl f\u00fcr R\u00f6ntgenmikroskopie, Universit\u00e4t W\u00fcrzburg, Josef-Martin-Weg 63, 97074 W\u00fcrzburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Zabler","sequence":"additional","affiliation":[{"name":"Lehrstuhl f\u00fcr R\u00f6ntgenmikroskopie, Universit\u00e4t W\u00fcrzburg, Josef-Martin-Weg 63, 97074 W\u00fcrzburg, Germany"},{"name":"Fraunhofer EZRT, NCTS Group W\u00fcrzburg, Josef-Martin-Weg 63, 97074 W\u00fcrzburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,6,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3287","DOI":"10.1063\/1.1516611","article-title":"Differential x-ray phase contrast imaging using a shearing interferometer","volume":"81","author":"David","year":"2002","journal-title":"Appl. Phys. Lett."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"L866","DOI":"10.1143\/JJAP.42.L866","article-title":"Demonstration of X-Ray Talbot Interferometry","volume":"42","author":"Momose","year":"2003","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1038\/nphys265","article-title":"Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources","volume":"2","author":"Pfeiffer","year":"2006","journal-title":"Nat. Phys."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"073709","DOI":"10.1063\/1.3465334","article-title":"Noise analysis of grating-based x-ray differential phase contrast imaging","volume":"81","author":"Revol","year":"2010","journal-title":"Rev. Sci. Instrum."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"6441","DOI":"10.1088\/0031-9155\/61\/17\/6441","article-title":"Optimisation of image reconstruction for phase-contrast x-ray Talbot\u2013Lau imaging with regard to mechanical robustness","volume":"61","author":"Seifert","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.optcom.2012.09.017","article-title":"Generalization of the Principal Component Analysis algorithm for interferometry","volume":"286","author":"Vargas","year":"2013","journal-title":"Opt. Commun."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"034005","DOI":"10.1117\/1.JMI.4.3.034005","article-title":"Improved reconstruction of phase-stepping data for Talbot-Lau x-ray imaging","volume":"4","author":"Kaeppler","year":"2017","journal-title":"J. Med. Imaging"},{"key":"ref_8","unstructured":"Von Teuffenbach, M., Noichl, W., Brendel, B., Herzen, J., Pfeiffer, F., Koehler, T., and No\u00ebl, P.B. (2017, January 12\u201315). Grating Position Estimation for Grating-based Computed Tomography. Proceedings of the Conference on X-ray and Neutron Phase Imaging with Gratings, XNPIG 2017, Zurich, Switzerland."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Ritter, A., Anton, G., and Weber, T. (2016). Simultaneous Maximum-Likelihood Reconstruction of Absorption Coefficient, Reconstruction of Absorption Coefficient, Refractive Index and Dark-Field Scattering Coefficient in X-Ray Talbot-Lau Tomography. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0163016"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"12707","DOI":"10.1364\/OE.26.012707","article-title":"Analysis and correction of bias induced by phase stepping jitter in grating-based X-ray phase-contrast imaging","volume":"26","author":"Marco","year":"2018","journal-title":"Opt. Express"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"16890","DOI":"10.1364\/OE.18.016890","article-title":"On the origin of visibility contrast in x-ray Talbot interferometry","volume":"18","author":"Yashiro","year":"2010","journal-title":"Opt. Express"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"5529","DOI":"10.1088\/0031-9155\/55\/18\/017","article-title":"Quantitative x-ray dark-field computed tomography","volume":"55","author":"Bech","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"7243","DOI":"10.1038\/srep07243","article-title":"General solution for quantitative dark-field contrast imaging with grating interferometers","volume":"4","author":"Strobl","year":"2014","journal-title":"Sci. Rep."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3317","DOI":"10.1088\/0031-9155\/55\/12\/004","article-title":"Directional x-ray dark-field imaging","volume":"55","author":"Jensen","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"114903","DOI":"10.1063\/1.4768525","article-title":"Orientation-selective X-ray dark field imaging of ordered systems","volume":"112","author":"Revol","year":"2012","journal-title":"J. Appl. Phys."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"38002","DOI":"10.1209\/0295-5075\/105\/38002","article-title":"X-ray tensor tomography","volume":"105","author":"Malecki","year":"2014","journal-title":"Europhys. Lett."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"12699","DOI":"10.1073\/pnas.1321080111","article-title":"Reconstruction of scalar and vectorial components in X-ray dark-field tomography","volume":"111","author":"Bayer","year":"2014","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"15134","DOI":"10.1364\/OE.23.015134","article-title":"Constrained X-ray tensor tomography reconstruction","volume":"23","author":"Vogel","year":"2015","journal-title":"Opt. Express"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"158101","DOI":"10.1103\/PhysRevLett.117.158101","article-title":"Anisotropic X-ray Dark-Field Tomography: A Continuous Model and its Discretization","volume":"117","author":"Wieczorek","year":"2016","journal-title":"Phys. Rev. Lett."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"134102","DOI":"10.1063\/1.4963649","article-title":"Six dimensional X-ray Tensor Tomography with a compact laboratory setup","volume":"109","author":"Sharma","year":"2016","journal-title":"Appl. Phys. Lett."},{"key":"ref_21","unstructured":"Dittmann, J., Zabler, S., and Hanke, R. (2017, January 12\u201315). Nested Tomography: Application to Direct Ellipsoid Reconstruction in Anisotropic Darkfield Tomography. Proceedings of the Conference on X-ray and Neutron Phase Imaging with Gratings, XNPIG 2017, Zurich, Switzerland."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/4\/6\/77\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:07:38Z","timestamp":1760195258000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/4\/6\/77"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,7]]},"references-count":21,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2018,6]]}},"alternative-id":["jimaging4060077"],"URL":"https:\/\/doi.org\/10.3390\/jimaging4060077","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,7]]}}}