{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T22:04:14Z","timestamp":1767650654827,"version":"build-2065373602"},"reference-count":21,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2018,11,16]],"date-time":"2018-11-16T00:00:00Z","timestamp":1542326400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","award":["Bench-to-Bedside Award","the NIH Center for Interventional Oncology Grant"],"award-info":[{"award-number":["Bench-to-Bedside Award","the NIH Center for Interventional Oncology Grant"]}],"id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["I-Corps Team Grant (1617340)","REU site program 1359095"],"award-info":[{"award-number":["I-Corps Team Grant (1617340)","REU site program 1359095"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007699","name":"University of Georgia","doi-asserted-by":"publisher","award":["the UGA-AU Inter-Institutional Seed Funding"],"award-info":[{"award-number":["the UGA-AU Inter-Institutional Seed Funding"]}],"id":[{"id":"10.13039\/100007699","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007495","name":"American Society for Quality","doi-asserted-by":"publisher","award":["Dr. Richard J. Schlesinger Grant"],"award-info":[{"award-number":["Dr. Richard J. Schlesinger Grant"]}],"id":[{"id":"10.13039\/100007495","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Clinical and Translational Science","award":["the PHS Grant UL1TR000454"],"award-info":[{"award-number":["the PHS Grant UL1TR000454"]}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["the NIH National Center for Advancing Translational Sciences"],"award-info":[{"award-number":["the NIH National Center for Advancing Translational Sciences"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Lung cancer is the leading cause of cancer-related deaths. Many methods and devices help acquire more accurate clinical and localization information during lung interventions and may impact the death rate for lung cancer. However, there is a learning curve for operating these tools due to the complex structure of the airway. In this study, we first discuss the creation of a lung phantom model from medical images, which is followed by a comparison of 3D printing in terms of quality and consistency. Two tests were conducted to test the performance of the developed phantom, which was designed for training simulations of the target and ablation processes in endochonchial interventions. The target test was conducted through an electromagnetic tracking catheter with navigation software. An ablation catheter with a recently developed thermochromic ablation gel conducted the ablation test. The results of two tests show that the phantom was very useful for target and ablation simulation. In addition, the thermochromic gel allowed doctors to visualize the ablation zone. Many lung interventions may benefit from custom training or accuracy with the proposed low-cost and patient-specific phantom.<\/jats:p>","DOI":"10.3390\/jimaging4110135","type":"journal-article","created":{"date-parts":[[2018,11,16]],"date-time":"2018-11-16T11:48:31Z","timestamp":1542368911000},"page":"135","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["3D Printing Endobronchial Models for Surgical Training and Simulation"],"prefix":"10.3390","volume":"4","author":[{"given":"Zhuo","family":"Zhao","sequence":"first","affiliation":[{"name":"School of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheng","family":"Xu","sequence":"additional","affiliation":[{"name":"Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, National Institute of Biomedical Imaging and Bioengineering, &amp; National Cancer Institute Center for Cancer Research, National Institutes of Health (NIH), Bethesda, MD 20892, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bradford J.","family":"Wood","sequence":"additional","affiliation":[{"name":"Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, National Institute of Biomedical Imaging and Bioengineering, &amp; National Cancer Institute Center for Cancer Research, National Institutes of Health (NIH), Bethesda, MD 20892, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9741-1137","authenticated-orcid":false,"given":"Zion Tsz Ho","family":"Tse","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602, USA"},{"name":"3T Technologies Limited Liability Company (LLC), GA 30067, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2018,11,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3322\/caac.21254","article-title":"Cancer statistics, 2015","volume":"65","author":"Siegel","year":"2015","journal-title":"CA Cancer J. Clin."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"017501","DOI":"10.1118\/1.4767757","article-title":"Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: Initial investigation of a combined model-and image-driven approach","volume":"40","author":"Uneri","year":"2013","journal-title":"Med. Phys."},{"key":"ref_3","first-page":"475","article-title":"Fiducial-free registration procedure for navigated bronchoscopy","volume":"Volume 4791","author":"Ayache","year":"2007","journal-title":"Medical Image Computing and Computer-Assisted Intervention\u2014MICCAI 2007. MICCAI 2007. Lecture Notes in Computer Science"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.compmedimag.2009.05.007","article-title":"Joint registration and segmentation of serial lung CT images for image-guided lung cancer diagnosis and therapy","volume":"34","author":"Xue","year":"2010","journal-title":"Comput. Med. Imaging Graph."},{"key":"ref_5","unstructured":"Centers for Disease Control and Prevention (CDC) (2018, September 16). Lung Cancer, 2017, Available online: https:\/\/www.cdc.gov\/cancer\/lung\/."},{"key":"ref_6","unstructured":"American Cancer Society (2018, September 16). How Common is Lung Cancer?. Available online: https:\/\/www.cancer.org\/cancer\/non-small-cell-lung-cancer\/about\/key-statistics.html."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.compmedimag.2012.03.002","article-title":"A minimally invasive multimodality image-guided (MIMIG) system for peripheral lung cancer intervention and diagnosis","volume":"36","author":"He","year":"2012","journal-title":"Comput. Med. Imaging Graph."},{"key":"ref_8","unstructured":"U.S. Food and Drug Administration (FDA) (2018, September 16). Lung Cancer and Smoking, 2017, Available online: https:\/\/www.fda.gov\/tobaccoproducts\/publichealtheducation\/healthinformation\/ucm468635.htm."},{"key":"ref_9","unstructured":"U.S. National Library of Medicine (2018, September 16). Lung Cancer, 2017, Available online: https:\/\/medlineplus.gov\/lungcancer.html."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1056\/NEJMoa060467","article-title":"A genomic strategy to refine prognosis in early-stage non\u2013small-cell lung cancer","volume":"355","author":"Potti","year":"2006","journal-title":"N. Engl. J. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.1097\/JTO.0b013e3181e8b2e6","article-title":"Cost-benefit of minimally invasive staging of non-small cell lung cancer: A decision tree sensitivity analysis","volume":"5","author":"Steinfort","year":"2010","journal-title":"J. Thorac. Oncol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1702","DOI":"10.1109\/TMI.2014.2321777","article-title":"Electromagnetic tracking in medicine\u2014A review of technology, validation, and applications","volume":"33","author":"Franz","year":"2014","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1097\/01.RVI.0000148827.62296.B4","article-title":"Navigation with electromagnetic tracking for interventional radiology procedures: A feasibility study","volume":"16","author":"Wood","year":"2005","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1120\/jacmp.v11i1.3081","article-title":"Development of a deformable lung phantom for the evaluation of deformable registration","volume":"11","author":"Chang","year":"2010","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref_15","first-page":"728","article-title":"Use of 3D printed materials as tissue-equivalent phantoms","volume":"Volume 51","author":"Jaffray","year":"2015","journal-title":"IFMBE Proceedings, Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Toronto, Canada, 7\u201312 June 2015"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2070","DOI":"10.1118\/1.2737158","article-title":"Design, development, and implementation of the radiological physics center\u2019s pelvis and thorax anthropomorphic quality assurance phantoms","volume":"34","author":"Followill","year":"2007","journal-title":"Med. Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1055\/s-0031-1280654","article-title":"Microwave lung ablation complicated by bronchocutaneous fistula: Case report and literature review","volume":"Volume 28","author":"Bui","year":"2011","journal-title":"Seminars in Interventional Radiology"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1007\/s11547-011-0741-2","article-title":"Complications of microwave and radiofrequency lung ablation: Personal experience and review of the literature","volume":"117","author":"Carrafiello","year":"2012","journal-title":"Radiol. Med."},{"key":"ref_19","unstructured":"Townsend, C.M., Beauchamp, R.D., Evers, B.M., and Mattox, K.L. (2012). Textbook of Surgery, Elsevier. [19th ed.]."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"4304","DOI":"10.1118\/1.4953394","article-title":"Evaluation of a tissue-mimicking thermochromic phantom for radiofrequency ablation","volume":"43","author":"Mikhail","year":"2016","journal-title":"Med. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1002\/rcs.1441","article-title":"CT-guided robotic needle biopsy of lung nodules with respiratory motion\u2013experimental system and preliminary test","volume":"9","author":"Zhou","year":"2013","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/4\/11\/135\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:30:03Z","timestamp":1760196603000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/4\/11\/135"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,16]]},"references-count":21,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2018,11]]}},"alternative-id":["jimaging4110135"],"URL":"https:\/\/doi.org\/10.3390\/jimaging4110135","relation":{},"ISSN":["2313-433X"],"issn-type":[{"type":"electronic","value":"2313-433X"}],"subject":[],"published":{"date-parts":[[2018,11,16]]}}}