{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T02:50:01Z","timestamp":1760237401366,"version":"build-2065373602"},"reference-count":22,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2020,5,19]],"date-time":"2020-05-19T00:00:00Z","timestamp":1589846400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.<\/jats:p>","DOI":"10.3390\/jimaging6050035","type":"journal-article","created":{"date-parts":[[2020,5,20]],"date-time":"2020-05-20T02:48:24Z","timestamp":1589942904000},"page":"35","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["On a Method For Reconstructing Computed Tomography Datasets from an Unstable Source"],"prefix":"10.3390","volume":"6","author":[{"given":"Nicholas","family":"Stull","sequence":"first","affiliation":[{"name":"Los Alamos National Laboratory, Los Alamos, NM 87545, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josh","family":"McCumber","sequence":"additional","affiliation":[{"name":"Phoenix, LLC., Monona, WI 53713, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lawrence","family":"D'Aries","sequence":"additional","affiliation":[{"name":"US Army CCDC-Armaments Center, Picatinny Arsenal, NJ 07806, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michelle","family":"Espy","sequence":"additional","affiliation":[{"name":"Los Alamos National Laboratory, Los Alamos, NM 87545, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cort","family":"Gautier","sequence":"additional","affiliation":[{"name":"Los Alamos National Laboratory, Los Alamos, NM 87545, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James","family":"Hunter","sequence":"additional","affiliation":[{"name":"Los Alamos National Laboratory, Los Alamos, NM 87545, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,5,19]]},"reference":[{"key":"ref_1","first-page":"132","article-title":"Ueber eine neue Art von Strahlen: Vorl\u00e4ufige Mitteilung","volume":"137","year":"1895","journal-title":"Sitzungsber. Phys. Med. Gesell."},{"key":"ref_2","unstructured":"(2020, May 12). The Nobel Prize in Physics 1901. Nobel Media AB 2020. Available online: https:\/\/www.nobelprize.org\/prizes\/physics\/1901\/summary\/."},{"key":"ref_3","first-page":"262","article-title":"Uber die Bestimmung von Funktionen durch ihre Integralwerte Langs Gewisser Mannifaltigkeiten [On the determination of functions from their integrals along certain manifolds]","volume":"69","author":"Radon","year":"1917","journal-title":"Ber. Saechsische Akad. Wiss."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1259\/0007-1285-46-552-1016","article-title":"Computerized transverse axial scanning (tomography), Part 1: Description of system","volume":"46","author":"Hounsfield","year":"1973","journal-title":"Br. J. Radiol."},{"key":"ref_5","first-page":"254","article-title":"Neutron Radiography","volume":"1","author":"Kalimann","year":"1948","journal-title":"Research"},{"key":"ref_6","first-page":"551","article-title":"Neutronen-Durchleuchtung","volume":"1","author":"Peter","year":"1946","journal-title":"Z. Naturforschung"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.nima.2003.12.042","article-title":"The effect of the imaging geometry and the impact of neutron scatter on the detection of small features in accelerator-based fast neutron radiography","volume":"524","author":"Ambrosi","year":"2004","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Nelson, R.O., Vogel, S.C., Hunter, J.F., Watkins, E.B., Losko, A.S., Tremsin, A.S., Borges, N.P., Cutler, T.E., Dickman, L.T., and Espy, M.A. (2018). Neutron Imaging at LANSCE-From Cold to Ultrafast. J. Imaging, 4.","DOI":"10.3390\/jimaging4020045"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/S0168-583X(98)00043-3","article-title":"Factors affecting image formation in accelerator-based fast neutron radiography","volume":"139","author":"Ambrosi","year":"1998","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.phpro.2015.07.039","article-title":"Fast Neutron Tomography of low-Z object in high-Z material shielding","volume":"69","author":"Babai","year":"2014","journal-title":"Phys. Procedia"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1016\/j.nima.2006.02.178","article-title":"Los Alamos Neutron Science Center","volume":"562","author":"Lisowski","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A"},{"key":"ref_12","unstructured":"Object Research Systems (ORS) Inc. (2020, May 07). Dragonfly | 3D Visualization and Analysis Solutions for Scientific and Industrial Data | ORS. Software Package. Available online: https:\/\/www.theobjects.com\/dragonfly\/."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/S0168-9002(01)01834-4","article-title":"Optimisation of resolution in accelerator-based fast neutron radiography","volume":"477","author":"Rahmanian","year":"2002","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Sepctrom Detect. Assoc. Equip."},{"key":"ref_14","first-page":"1447","article-title":"Evaluation of Wavelength Dependent Detection Efficiency of Neutron-Sensitive Microchannel Plate Detector","volume":"29","author":"Watanabe","year":"2017","journal-title":"Sens. Mater."},{"key":"ref_15","unstructured":"(2020, May 07). Organic Scintillation Materials | Saint Gobain Crystals. Available online: https:\/\/www.crystals.saint-gobain.com\/products\/organic-scintillation-materials."},{"key":"ref_16","unstructured":"(2020, May 07). Elien Technology\u2013Organic Scintillators\u2013Plastic Scintillators. Available online: http:\/\/www.eljentechnology.com\/products\/plastic-scintillators."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Winch, N.M., Madden, A.C., Hunter, J.F., and Nelson, R.O. (2017, January 21\u201328). Detector Performance for Fast Neutron Radiography and Computed Tomography. Proceedings of the 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS\/MIC), Atlanta, GA, USA.","DOI":"10.1109\/NSSMIC.2017.8533124"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"208","DOI":"10.13182\/NSE90-A27471","article-title":"The Los Alamos National Laboratory Spallation Neutron Sources","volume":"106","author":"Lisowski","year":"1990","journal-title":"Nucl. Sci. Eng."},{"key":"ref_19","unstructured":"The MathWorks, Inc. (2020, May 07). Matlab 2019b. Mathworks - MATLAB - MATLAB and Simulink. Available online: https:\/\/www.mathworks.com\/."},{"key":"ref_20","unstructured":"Kak, A.C., and Slaney, M. (1987). Principles of Computed Tomographic Imaging (Classics in Applied Mathematics, Book 33), Society of Industrial and Applied Mathematics."},{"key":"ref_21","unstructured":"Buzug, T.M. (2008). Computed Tomography: From Photon Statistics to Modern Cone-Beam CT, Springer."},{"key":"ref_22","unstructured":"Volume Graphics Inc. (2020, May 07). VGSTUDIO MAX\u2014Products. Software Package. Available online: https:\/\/www.volumegraphics.com\/en\/products\/vgstudio-max.html."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/6\/5\/35\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:30:08Z","timestamp":1760175008000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/6\/5\/35"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,19]]},"references-count":22,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2020,5]]}},"alternative-id":["jimaging6050035"],"URL":"https:\/\/doi.org\/10.3390\/jimaging6050035","relation":{},"ISSN":["2313-433X"],"issn-type":[{"type":"electronic","value":"2313-433X"}],"subject":[],"published":{"date-parts":[[2020,5,19]]}}}