{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T17:54:51Z","timestamp":1790531691694,"version":"4.1.0"},"reference-count":65,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2021,3,19]],"date-time":"2021-03-19T00:00:00Z","timestamp":1616112000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Over the last decade, the combination of compressed sensing (CS) with acquisition over multiple receiver coils in magnetic resonance imaging (MRI) has allowed the emergence of faster scans while maintaining a good signal-to-noise ratio (SNR). Self-calibrating techniques, such as ESPiRIT, have become the standard approach to estimating the coil sensitivity maps prior to the reconstruction stage. In this work, we proceed differently and introduce a new calibration-less multi-coil CS reconstruction method. Calibration-less techniques no longer require the prior extraction of sensitivity maps to perform multi-coil image reconstruction but usually alternate estimation sensitivity map estimation and image reconstruction. Here, to get rid of the nonconvexity of the latter approach we reconstruct as many MR images as the number of coils. To compensate for the ill-posedness of this inverse problem, we leverage structured sparsity of the multi-coil images in a wavelet transform domain while adapting to variations in SNR across coils owing to the OSCAR (octagonal shrinkage and clustering algorithm for regression) regularization. Coil-specific complex-valued MR images are thus obtained by minimizing a convex but nonsmooth objective function using the proximal primal-dual Condat-V\u00f9 algorithm. Comparison and validation on retrospective Cartesian and non-Cartesian studies based on the Brain fastMRI data set demonstrate that the proposed reconstruction method outperforms the state-of-the-art (\u21131-ESPIRiT, calibration-less AC-LORAKS and CaLM methods) significantly on magnitude images for the T1 and FLAIR contrasts. Additionally, further validation operated on 8 to 20-fold prospectively accelerated high-resolution ex vivo human brain MRI data collected at 7 Tesla confirms the retrospective results. Overall, OSCAR-based regularization preserves phase information more accurately (both visually and quantitatively) compared to other approaches, an asset that can only be assessed on real prospective experiments.<\/jats:p>","DOI":"10.3390\/jimaging7030058","type":"journal-article","created":{"date-parts":[[2021,3,19]],"date-time":"2021-03-19T11:18:38Z","timestamp":1616152718000},"page":"58","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization"],"prefix":"10.3390","volume":"7","author":[{"given":"Loubna","family":"El Gueddari","sequence":"first","affiliation":[{"name":"NeuroSpin, CEA, Universit\u00e9 Paris-Saclay, 91191 Gif-sur-Yvette, France"},{"name":"Parietal, Inria, 91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9859-6006","authenticated-orcid":false,"given":"Chaithya","family":"Giliyar Radhakrishna","sequence":"additional","affiliation":[{"name":"NeuroSpin, CEA, Universit\u00e9 Paris-Saclay, 91191 Gif-sur-Yvette, France"},{"name":"Parietal, Inria, 91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3631-6093","authenticated-orcid":false,"given":"Emilie","family":"Chouzenoux","sequence":"additional","affiliation":[{"name":"OPIS, Inria, Universit\u00e9 Paris-Saclay, 91190 Gif-sur-Yvette, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5374-962X","authenticated-orcid":false,"given":"Philippe","family":"Ciuciu","sequence":"additional","affiliation":[{"name":"NeuroSpin, CEA, Universit\u00e9 Paris-Saclay, 91191 Gif-sur-Yvette, France"},{"name":"Parietal, Inria, 91120 Palaiseau, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,3,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1109\/TIT.2006.871582","article-title":"Compressed sensing","volume":"52","author":"Donoho","year":"2006","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1109\/TIT.2005.862083","article-title":"Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information","volume":"52","author":"Romberg","year":"2006","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: The application of compressed sensing for rapid MR imaging","volume":"58","author":"Lustig","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1109\/MSP.2007.914728","article-title":"Compressed Sensing MRI","volume":"25","author":"Lustig","year":"2008","journal-title":"IEEE Signal Process. Mag."},{"key":"ref_5","unstructured":"(2019, April 15). FDA Clears Compressed Sensing MRI Acceleration Technology from Siemens Healthineers. Available online: https:\/\/www.siemens-healthineers.com\/en-us\/news\/fda-clears-mri-technology-02-21-2017.html."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<963::AID-MRM17>3.0.CO;2-L","article-title":"Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging","volume":"42","author":"Pipe","year":"1999","journal-title":"Magn. Reson. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1002\/mrm.10644","article-title":"Fast 3D imaging using variable-density spiral trajectories with applications to limb perfusion","volume":"50","author":"Lee","year":"2003","journal-title":"Magn. Reson. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1002\/mrm.25665","article-title":"XD-GRASP: Golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing","volume":"75","author":"Feng","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1137\/16M1059205","article-title":"On the generation of sampling schemes for magnetic resonance imaging","volume":"9","author":"Boyer","year":"2016","journal-title":"SIAM J. Imaging Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.neuroimage.2017.07.062","article-title":"Rapid anatomical brain imaging using spiral acquisition and an expanded signal model","volume":"168","author":"Kasper","year":"2018","journal-title":"Neuroimage"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3643","DOI":"10.1002\/mrm.27678","article-title":"SPARKLING: Variable-density k-space filling curves for accelerated T2*-weighted MRI","volume":"81","author":"Lazarus","year":"2019","journal-title":"Magn. Reson. Med."},{"key":"ref_12","unstructured":"Chaithya, G.R., Weiss, P., Massire, A., Vignaud, A., and Ciuciu, P. (2020). Globally optimized 3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance imaging. IEEE Trans. Med. Imaging, under review."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1002\/mrm.1910160203","article-title":"The NMR phased array","volume":"16","author":"Roemer","year":"1990","journal-title":"Magn. Reson. Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1002\/mrm.24997","article-title":"Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion","volume":"72","author":"Shin","year":"2014","journal-title":"Magn. Reson. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1002\/mrm.25717","article-title":"P-LORAKS: Low-rank modeling of local k-space neighborhoods with parallel imaging data","volume":"75","author":"Haldar","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1109\/TMI.2011.2140121","article-title":"A fast wavelet-based reconstruction method for magnetic resonance imaging","volume":"30","author":"Haberlin","year":"2011","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.media.2010.08.001","article-title":"A wavelet-based regularized reconstruction algorithm for SENSE parallel MRI with applications to neuroimaging","volume":"15","author":"Pesquet","year":"2011","journal-title":"Med. Image Anal."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Chauffert, N., Ciuciu, P., and Weiss, P. (2013, January 7\u201311). Variable density compressed sensing in MRI. Theoretical vs heuristic sampling strategies. Proceedings of the 10th IEEE International Symposium on Biomedical Imaging (ISBI 2013), San Francisco, CA, USA.","DOI":"10.1109\/ISBI.2013.6556471"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.1137\/130946642","article-title":"Variable density sampling with continuous trajectories. Application to MRI","volume":"7","author":"Chauffert","year":"2014","journal-title":"SIAM J. Imaging Sci."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1002\/mrm.10087","article-title":"Self-calibrating parallel imaging with automatic coil sensitivity extraction","volume":"47","author":"McKenzie","year":"2002","journal-title":"Magn. Reson. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1002\/mrm.24751","article-title":"ESPIRiT\u2014An eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA","volume":"71","author":"Uecker","year":"2014","journal-title":"Magn. Reson. Med."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Gueddari, L., Lazarus, C., Carri\u00e9, H., Vignaud, A., and Ciuciu, P. (2018, January 8\u201311). Self-calibrating nonlinear reconstruction algorithms for variable density sampling and parallel reception MRI. Proceedings of the IEEE 10th Sensor Array and Multichannel Signal Processing Workshop (SAM 2018), Sheffield, UK.","DOI":"10.1109\/SAM.2018.8448776"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1002\/mrm.21245","article-title":"Joint image reconstruction and sensitivity estimation in SENSE (JSENSE)","volume":"57","author":"Ying","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1002\/mrm.21691","article-title":"Image reconstruction by regularized nonlinear inversion\u2014Joint estimation of coil sensitivities and image content","volume":"60","author":"Uecker","year":"2008","journal-title":"Magn. Reson. Med."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1002\/cmr.a.21244","article-title":"Iterative estimation of MRI sensitivity maps and image based on sense reconstruction method (isense)","volume":"40","author":"Majumdar","year":"2012","journal-title":"Concepts Magn. Reson. Part A"},{"key":"ref_26","unstructured":"Dwork, N., Johnson, E.M., O\u2019Connor, D., Gordon, J.W., Kerr, A.B., Baron, C.A., Pauly, J.M., and Larson, P.E. (2020). Calibrationless Multi-coil Magnetic Resonance Imaging with Compressed Sensing. arXiv."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1016\/j.mri.2012.02.025","article-title":"Calibration-less multi-coil MR image reconstruction","volume":"30","author":"Majumdar","year":"2012","journal-title":"Magn. Reson. Imaging"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1109\/TMI.2015.2474383","article-title":"Efficient compressed sensing SENSE pMRI reconstruction with joint sparsity promotion","volume":"35","author":"Chun","year":"2016","journal-title":"IEEE Trans. Med Imaging"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Trzasko, J., and Manduca, A. (2011, January 6\u20139). Calibrationless parallel MRI using CLEAR. Proceedings of the 45th Asilomar Conference on Signals, Systems and Computers (ASILOMAR 2011), Pacific Grove, CA, USA.","DOI":"10.1109\/ACSSC.2011.6189958"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1111\/j.1541-0420.2007.00843.x","article-title":"Simultaneous regression shrinkage, variable selection, and supervised clustering of predictors with OSCAR","volume":"64","author":"Bondell","year":"2008","journal-title":"Biometrics"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1214\/15-AOAS842","article-title":"SLOPE-adaptive variable selection via convex optimization","volume":"9","author":"Bogdan","year":"2015","journal-title":"Ann. Appl. Stat."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Bauschke, H.H., and Combettes, P.L. (2017). Convex Analysis and Monotone Operator Theory in Hilbert Spaces, Springer International Publishing. [2nd ed.].","DOI":"10.1007\/978-3-319-48311-5"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"273","DOI":"10.24033\/bsmf.1625","article-title":"Proximit\u00e9 et dualit\u00e9 dans un espace hilbertien","volume":"93","author":"Moreau","year":"1965","journal-title":"Bull. De La Soci\u00e9t\u00e9 Math\u00e9matique De Fr."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1002\/mrm.1910370523","article-title":"Multifrequency interpolation for fast off-resonance correction","volume":"37","author":"Man","year":"1997","journal-title":"Magn. Reson. Med."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1145\/1555386.1555388","article-title":"Using NFFT 3\u2014a software library for various nonequispaced fast Fourier transforms","volume":"36","author":"Keiner","year":"2009","journal-title":"ACM Trans. Math. Softw. (TOMS)"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1109\/TSP.2002.807005","article-title":"Nonuniform fast Fourier transforms using min-max interpolation","volume":"51","author":"Fessler","year":"2003","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1088\/0266-5611\/23\/3\/007","article-title":"Analysis versus synthesis in signal priors","volume":"23","author":"Elad","year":"2007","journal-title":"Inverse Probl."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.sigpro.2013.09.026","article-title":"A majorize-minimize memory gradient method for complex-valued inverse problems","volume":"103","author":"Florescu","year":"2014","journal-title":"Signal Process."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1002\/mrm.24932","article-title":"Phase reconstruction from multiple coil data using a virtual reference coil","volume":"72","author":"Parker","year":"2014","journal-title":"Magn. Reson. Med."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1109\/MSP.2014.2377273","article-title":"Playing with Duality: An overview of recent primal-dual approaches for solving large-scale optimization problems","volume":"32","author":"Komodakis","year":"2015","journal-title":"IEEE Signal Process. Mag."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Combettes, P., and Pesquet, J. (2021). Fixed Point Strategies in Data Science. arXiv.","DOI":"10.1109\/TSP.2021.3069677"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1007\/s10957-012-0245-9","article-title":"A Primal\u2013Dual Splitting Method for Convex Optimization Involving Lipschitzian, Proximable and Linear Composite Terms","volume":"158","author":"Condat","year":"2013","journal-title":"J. Optim. Theory Appl."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1007\/s10444-011-9254-8","article-title":"A splitting algorithm for dual monotone inclusions involving cocoercive operators","volume":"38","year":"2013","journal-title":"Adv. Comput. Math."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Combettes, P.L., and Pesquet, J.C. (2011). Proximal splitting methods in signal processing. Fixed-Point Algorithms for Inverse Problems in Science and Engineering, Springer.","DOI":"10.1007\/978-1-4419-9569-8_10"},{"key":"ref_45","unstructured":"Zeng, X., and Figueiredo, M.A. (2014). The Ordered Weighted l1 Norm: Atomic Formulation, Projections, and Algorithms. arXiv."},{"key":"ref_46","first-page":"1","article-title":"Isotone optimization in R: Pool-adjacent-violators algorithm (PAVA) and active set methods","volume":"32","author":"Mair","year":"2009","journal-title":"J. Stat. Softw."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1111\/j.1467-9868.2005.00503.x","article-title":"Regularization and variable selection via the elastic net","volume":"67","author":"Zou","year":"2005","journal-title":"J. R. Stat. Soc. Ser. B (Stat. Methodol.)"},{"key":"ref_48","unstructured":"Argyriou, A., Foygel, R., and Srebro, N. (2012). Sparse Prediction with the k-Support Norm. arXiv."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Haldar, J.P. (2015, January 16\u201319). Autocalibrated LORAKS for fast constrained MRI reconstruction. Proceedings of the IEEE 12th International Symposium on Biomedical Imaging (ISBI 2015), Brooklyn, NY, USA.","DOI":"10.1109\/ISBI.2015.7164018"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Cherkaoui, H., Gueddari, L., Lazarus, C., Grigis, A., Poupon, F., Vignaud, A., Farrens, S., Starck, J., and Ciuciu, P. (2018, January 3\u20137). Analysis vs Synthesis-based Regularization for combined Compressed Sensing and Parallel MRI Reconstruction at 7 Tesla. Proceedings of the 26th European Signal Processing Conference (EUSIPCO 2018), Rome, Italy.","DOI":"10.23919\/EUSIPCO.2018.8553476"},{"key":"ref_51","unstructured":"Gueddari, L.E., Chaithya, G.R., Ramzi, Z., Farrens, S., Starck, S., Grigis, A., Starck, J.L., and Ciuciu, P. (2020, January 26\u201329). PySAP-MRI: A Python Package for MR Image Reconstruction. Proceedings of the ISMRM Workshop on Data Sampling and Image Reconstruction, Sedona, AZ, USA."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"100402","DOI":"10.1016\/j.ascom.2020.100402","article-title":"PySAP: Python Sparse Data Analysis Package for multidisciplinary image processing","volume":"32","author":"Farrens","year":"2020","journal-title":"Astron. Comput."},{"key":"ref_53","unstructured":"Knoll, F., Schwarzl, A., Diwoky, C., and Sodickson, D. (2014, January 10\u201316). gpuNUFFT\u2014An Open Source GPU Library for 3D Regridding with Direct Matlab Interface. Proceedings of the 22nd Annual Meeting of ISMRM, Milan, Italy."},{"key":"ref_54","unstructured":"Zbontar, J., Knoll, F., Sriram, A., Muckley, M.J., Bruno, M., Defazio, A., Parente, M., Geras, K.J., Katsnelson, J., and Chandarana, H. (2018). fastMRI: An Open Dataset and Benchmarks for Accelerated MRI. arXiv."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"e190007","DOI":"10.1148\/ryai.2020190007","article-title":"fastMRI: A publicly available raw k-space and DICOM dataset of knee images for accelerated MR image reconstruction using machine learning","volume":"2","author":"Knoll","year":"2020","journal-title":"Radiol. Artif. Intell."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TIP.2003.819861","article-title":"Image quality assessment: From error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans. Image Process."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1002\/mrm.20198","article-title":"Susceptibility weighted imaging (SWI)","volume":"52","author":"Haacke","year":"2004","journal-title":"Magn. Reson. Med."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1109\/TMI.2010.2093536","article-title":"Parallel MR image reconstruction using augmented Lagrangian methods","volume":"30","author":"Ramani","year":"2010","journal-title":"IEEE Trans. Med Imaging"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1038\/nature25988","article-title":"Image reconstruction by domain-transform manifold learning","volume":"555","author":"Zhu","year":"2018","journal-title":"Nature"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1109\/TMI.2018.2858752","article-title":"Deep generative adversarial neural networks for compressive sensing MRI","volume":"38","author":"Mardani","year":"2018","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Ramzi, Z., Ciuciu, P., and Starck, J.L. (2020). Benchmarking MRI reconstruction neural networks on large public datasets. Appl. Sci., 10.","DOI":"10.3390\/app10051816"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Antun, V., Renna, F., Poon, C., Adcock, B., and Hansen, A.C. (2019). On instabilities of deep learning in image reconstruction-Does AI come at a cost?. arXiv.","DOI":"10.1073\/pnas.1907377117"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"3659","DOI":"10.1109\/TIP.2012.2195015","article-title":"Regularization parameter selection for nonlinear iterative image restoration and MRI reconstruction using GCV and SURE-based methods","volume":"21","author":"Ramani","year":"2012","journal-title":"IEEE Trans. Image Process."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.acha.2015.07.006","article-title":"Generalized sampling reconstruction from Fourier measurements using compactly supported shearlets","volume":"42","author":"Ma","year":"2017","journal-title":"Appl. Comput. Harmon. Anal."},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"El Gueddari, L., Chouzenoux, E., Vignaud, A., Pesquet, J.C., and Ciuciu, P. (2019, January 13\u201315). Online MR image reconstruction for compressed sensing acquisition in T2* imaging. Proceedings of the Wavelets and Sparsity XVIII. International Society for Optics and Photonics, San Diego, CA, USA.","DOI":"10.1117\/12.2527881"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/7\/3\/58\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:38:05Z","timestamp":1760161085000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/7\/3\/58"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,19]]},"references-count":65,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2021,3]]}},"alternative-id":["jimaging7030058"],"URL":"https:\/\/doi.org\/10.3390\/jimaging7030058","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,19]]}}}