{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T13:52:48Z","timestamp":1773841968750,"version":"3.50.1"},"reference-count":18,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2021,8,15]],"date-time":"2021-08-15T00:00:00Z","timestamp":1628985600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100010665","name":"H2020 Marie Sk\u0142odowska-Curie Actions","doi-asserted-by":"publisher","award":["765604"],"award-info":[{"award-number":["765604"]}],"id":[{"id":"10.13039\/100010665","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>The reconstruction of cone-beam computed tomography data using filtered back-projection algorithms unavoidably results in severe artefacts. We describe how the Direct Iterative Reconstruction of Computed Tomography Trajectories (DIRECTT) algorithm can be combined with a model of the artefacts for the reconstruction of such data. The implementation of DIRECTT results in reconstructed volumes of superior quality compared to the conventional algorithms.<\/jats:p>","DOI":"10.3390\/jimaging7080147","type":"journal-article","created":{"date-parts":[[2021,8,15]],"date-time":"2021-08-15T21:43:55Z","timestamp":1629063835000},"page":"147","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Suppression of Cone-Beam Artefacts with Direct Iterative Reconstruction Computed Tomography Trajectories (DIRECTT)"],"prefix":"10.3390","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5785-4080","authenticated-orcid":false,"given":"Sotirios","family":"Magkos","sequence":"first","affiliation":[{"name":"Bundesanstalt f\u00fcr Materialforschung und -pr\u00fcfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1585-1743","authenticated-orcid":false,"given":"Andreas","family":"Kupsch","sequence":"additional","affiliation":[{"name":"Bundesanstalt f\u00fcr Materialforschung und -pr\u00fcfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9632-3960","authenticated-orcid":false,"given":"Giovanni","family":"Bruno","sequence":"additional","affiliation":[{"name":"Bundesanstalt f\u00fcr Materialforschung und -pr\u00fcfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany"},{"name":"Institute of Physics and Astronomy, University of Potsdam, Karl-Liebknecht-Str. 24-25, 14476 Potsdam, Germany"}]}],"member":"1968","published-online":{"date-parts":[[2021,8,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/j.cirp.2014.05.011","article-title":"Industrial applications of computed tomography","volume":"63","author":"Carmignato","year":"2014","journal-title":"CIRP Ann."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1524\/teme.2008.0822","article-title":"Ermittlung der Messunsicherheit von Computertomographie-Messungen am Beispiel eines Zylinderkopfs (Determination of the Measurement Uncertainty of Computed Tomography Measurements Using a Cylinder Head as an Example)","volume":"75","author":"Bartscher","year":"2008","journal-title":"TM Tech. Mess."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.cirp.2012.03.021","article-title":"Accuracy of industrial computed tomography measurements: Experimental results from an international comparison","volume":"61","author":"Carmignato","year":"2012","journal-title":"CIRP Ann."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Brunke, O., L\u00fcbbeh\u00fcsen, J., Hansen, F., and Butz, F.F. (2013). A new Concept for High-Speed atline and inlineCT for up to 100% Mass Production Process Control. International Congress of Metrology, EDP Sciences.","DOI":"10.1051\/metrology\/201306003"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1137\/0143035","article-title":"An Inversion Formula for Cone-Beam Reconstruction","volume":"43","author":"Tuy","year":"1983","journal-title":"SIAM J. Appl. Math."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1364\/JOSAA.1.000612","article-title":"Practical cone-beam algorithm","volume":"1","author":"Feldkamp","year":"1984","journal-title":"J. Opt. Soc. Am. A"},{"key":"ref_7","unstructured":"Hsieh, J. (2000). Two-pass algorithm for cone-beam reconstruction. Medical Imaging 2000: Image Processing, International Society for Optics and Photonics."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"10108","DOI":"10.1364\/OE.27.010108","article-title":"Multi-pass approach to reduce cone-beam artifacts in a circular orbit cone-beam CT system","volume":"27","author":"Han","year":"2019","journal-title":"Opt. Express"},{"key":"ref_9","unstructured":"Maa\u00df, C., Dennerlein, F., Noo, F., and Kachelrie\u00df, M. (November, January 30). Comparing short scan CT reconstruction algorithms regarding cone-beam artifact performance. Proceedings of the IEEE Nuclear Science Symposuim & Medical Imaging Conference, Knoxville, TN, USA."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"272","DOI":"10.3139\/120.100885","article-title":"Computertomographische Rekonstruktion mit DIRECTT","volume":"50","author":"Lange","year":"2008","journal-title":"Mater. Test."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1111\/jmi.12313","article-title":"Missing wedge computed tomography by iterative algorithm DIRECTT","volume":"261","author":"Kupsch","year":"2016","journal-title":"J. Microsc."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"103107","DOI":"10.1063\/5.0013111","article-title":"Direct Iterative Reconstruction of Computed Tomography Trajectories Reconstruction from limited number of projections with DIRECTT","volume":"91","author":"Magkos","year":"2020","journal-title":"Rev. Sci. Instrum."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1088\/0031-9155\/45\/2\/306","article-title":"3D cone-beam CT reconstruction for circular trajectories","volume":"45","author":"Grass","year":"1999","journal-title":"Phys. Med. Biol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"25129","DOI":"10.1364\/OE.24.025129","article-title":"Fast and flexible X-ray tomography using the ASTRA toolbox","volume":"24","author":"Palenstijn","year":"2016","journal-title":"Opt. Express"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1109\/TMI.2008.923696","article-title":"Computational Analysis and Improvement of SIRT","volume":"27","author":"Gregor","year":"2008","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"409","DOI":"10.6028\/jres.049.044","article-title":"Methods of conjugate gradients for solving linear systems","volume":"49","author":"Hestenes","year":"1952","journal-title":"J. Res. Natl. Bur. Stand."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6016","DOI":"10.1038\/s41598-019-40837-7","article-title":"Metric-guided regularisation parameter selection for statistical iterative reconstruction in computed tomography","volume":"9","author":"Allner","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"59","DOI":"10.2307\/2685263","article-title":"Thirteen Ways to Look at the Correlation Coefficient","volume":"42","author":"Rodgers","year":"1988","journal-title":"Am. Stat."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/7\/8\/147\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:46:33Z","timestamp":1760165193000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/7\/8\/147"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,15]]},"references-count":18,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2021,8]]}},"alternative-id":["jimaging7080147"],"URL":"https:\/\/doi.org\/10.3390\/jimaging7080147","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,15]]}}}